search
Back to results

Pattern Recognition Prosthetic Control (Simultaneous)

Primary Purpose

Prosthesis User, Congenital Amputation of Upper Limb, Amputation; Traumatic, Limb

Status
Completed
Phase
Not Applicable
Locations
United States
Study Type
Interventional
Intervention
EMG-Pattern Recognition Controller
Sponsored by
Coapt, LLC
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional treatment trial for Prosthesis User focused on measuring pattern recognition, home trial, randomized cross-over trial, prosthesis, electromyography

Eligibility Criteria

18 Years - 70 Years (Adult, Older Adult)All SexesDoes not accept healthy volunteers

Inclusion Criteria:

  • Subjects have an upper-limb difference (congenital or acquired) at the transradial (between the wrist and elbow), elbow disarticulation (at the elbow), transhumeral (between the elbow and shoulder), or shoulder disarticulation (at the shoulder) level.
  • Subjects are suitable to be, or already are, a Coapt pattern recognition user (Coapt Complete Control Gen2 device).
  • Subjects are between the ages of 18 and 70.

Exclusion Criteria:

  • Subjects with significant cognitive deficits or visual impairment that would preclude them from giving informed consent or following instructions during the experiments, or the ability to obtain relevant user feedback discussion.
  • Subjects who are non-English speaking.
  • Subjects who are pregnant.

Sites / Locations

  • Coapt, LLC

Arms of the Study

Arm 1

Arm 2

Arm Type

Experimental

Active Comparator

Arm Label

Simultaneous Control

Conventional Control

Arm Description

Simultaneous pattern recognition style of control allows prosthetic users to actuate more than one hand/arm function on their device at the same time.

Conventional, seamless sequential pattern recognition style of control allows prosthetic users to actuate a single hand or arm functions on their device at a time.

Outcomes

Primary Outcome Measures

Differences in prosthetic wear time
We will record each instance participants turn on or off their pattern recognition device throughout the home trial. Prosthetic wear time is defined as the cumulative amount of time participants keep their pattern recognition device turned on during the course of each 8-week period. We will perform a statistical analysis to compare wear time when using each type of pattern recognition control (simultaneous and seamless, sequential). We will complete a repeated measures analysis of variance with subject as a random factor, order of control style used as a fixed variable, and wear time as a fixed variable.

Secondary Outcome Measures

Differences in classification accuracy
Participants will be instructed to use their pattern recognition device to make a set of motions (either independent or simultaneous motions) and hold each motion for 3 seconds. For each motion, we will record the output motion class determined by the classifier every 50 ms. We will measure the performance of the classier for each motion by computing the classification accuracy which is defined as the number of correct classifications over the total number of classifications. We will perform a statistical analysis to compare classification accuracy when using each control type (simultaneous and seamless, sequential). We will complete a repeated measures analysis of variance with subject as a random factor, order of control style used as a fixed variable, and classification accuracy as a fixed variable.
RIC's Orthotics Prosthetics User Survey
Participants will complete the Upper Extremity Functional Status module from RIC's Orthotics Prosthetics User Survey (OPUS). The OPUS asks prosthetic users to rate the level of difficulty (from very easy to very difficult) in performing upper arm/hand functions using their pattern recognition device. Survey data will be evaluated using rating scale analysis (Rasch model).
Changes in virtual game performance
Participants will complete a virtual game called Simon Says using the Coapt Complete ControlRoom desktop application. Simon Says is a Fitt's Law-style test that measures how well participants control each motion using their pattern recognition device by moving a virtual arm on a screen. Participants will be instructed to match and hold the position of a virtual arm in a target position for 1 second. Participants will complete each motion (either independent or simultaneous motions) 3 times. We will measure their overall performance by computing completion rate, movement time, path efficiency. We will perform a statistical analysis to compare virtual game performance when using each type of pattern recognition control. We will complete a repeated measures analysis of variance with subject as a random factor, order of control style used as a fixed variable, and each performance metric as a fixed variable.

Full Information

First Posted
February 13, 2020
Last Updated
October 19, 2022
Sponsor
Coapt, LLC
Collaborators
Eunice Kennedy Shriver National Institute of Child Health and Human Development (NICHD)
search

1. Study Identification

Unique Protocol Identification Number
NCT04272593
Brief Title
Pattern Recognition Prosthetic Control
Acronym
Simultaneous
Official Title
Simultaneous Pattern Recognition Control of Powered Upper Limb Prostheses
Study Type
Interventional

2. Study Status

Record Verification Date
October 2022
Overall Recruitment Status
Completed
Study Start Date
November 16, 2020 (Actual)
Primary Completion Date
July 18, 2022 (Actual)
Study Completion Date
July 18, 2022 (Actual)

3. Sponsor/Collaborators

Responsible Party, by Official Title
Sponsor
Name of the Sponsor
Coapt, LLC
Collaborators
Eunice Kennedy Shriver National Institute of Child Health and Human Development (NICHD)

4. Oversight

Studies a U.S. FDA-regulated Drug Product
No
Studies a U.S. FDA-regulated Device Product
Yes
Product Manufactured in and Exported from the U.S.
No
Data Monitoring Committee
No

5. Study Description

Brief Summary
This study investigates whether simultaneous electromyographic (EMG)-based pattern recognition control of an upper limb prostheses increases wear time among users. In contrast to conventional, seamless sequential pattern recognition style of control which only allows a single prosthetic hand or arm function at a time, simultaneous control allows for more than one at the same time. Participants will wear their prosthesis as they would normally at home using each control style for an 8-week period with an intermittent 1-week washout period (17 weeks total). Prosthetic usage will be monitored; including, how often participants wear their device and how many times they move each degree of freedom independently or simultaneously. The primary hypothesis is that prosthetic users will prefer simultaneous control over conventional control which will result in wearing their device more often. The secondary hypothesis is that simultaneous control will result in more efficient prosthesis control which will make it easier for participants to perform activities of daily living. The results of this study will help identify important factors related to prosthetic users' preferences while freely wearing their device within their own daily-life environment.

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Prosthesis User, Congenital Amputation of Upper Limb, Amputation; Traumatic, Limb
Keywords
pattern recognition, home trial, randomized cross-over trial, prosthesis, electromyography

7. Study Design

Primary Purpose
Treatment
Study Phase
Not Applicable
Interventional Study Model
Crossover Assignment
Model Description
The study is a randomized crossover home trial consisting of two 8-week periods with an intermittent 1-week washout period (17 weeks total). Participants will use either simultaneous control or convention seamless, sequential control in the first 8-week period followed by using the opposite control style in the second 8-week period.
Masking
None (Open Label)
Allocation
Randomized
Enrollment
8 (Actual)

8. Arms, Groups, and Interventions

Arm Title
Simultaneous Control
Arm Type
Experimental
Arm Description
Simultaneous pattern recognition style of control allows prosthetic users to actuate more than one hand/arm function on their device at the same time.
Arm Title
Conventional Control
Arm Type
Active Comparator
Arm Description
Conventional, seamless sequential pattern recognition style of control allows prosthetic users to actuate a single hand or arm functions on their device at a time.
Intervention Type
Device
Intervention Name(s)
EMG-Pattern Recognition Controller
Other Intervention Name(s)
Coapt Complete Control Gen2
Intervention Description
Using an electromyographic (EMG)-based pattern recognition controller to move an upper limb prosthetic device.
Primary Outcome Measure Information:
Title
Differences in prosthetic wear time
Description
We will record each instance participants turn on or off their pattern recognition device throughout the home trial. Prosthetic wear time is defined as the cumulative amount of time participants keep their pattern recognition device turned on during the course of each 8-week period. We will perform a statistical analysis to compare wear time when using each type of pattern recognition control (simultaneous and seamless, sequential). We will complete a repeated measures analysis of variance with subject as a random factor, order of control style used as a fixed variable, and wear time as a fixed variable.
Time Frame
We will record total prosthetic wear time during the course of each 8-week period.
Secondary Outcome Measure Information:
Title
Differences in classification accuracy
Description
Participants will be instructed to use their pattern recognition device to make a set of motions (either independent or simultaneous motions) and hold each motion for 3 seconds. For each motion, we will record the output motion class determined by the classifier every 50 ms. We will measure the performance of the classier for each motion by computing the classification accuracy which is defined as the number of correct classifications over the total number of classifications. We will perform a statistical analysis to compare classification accuracy when using each control type (simultaneous and seamless, sequential). We will complete a repeated measures analysis of variance with subject as a random factor, order of control style used as a fixed variable, and classification accuracy as a fixed variable.
Time Frame
We will record classification accuracy at the start (0-months), mid-point (1-months) and end (2-months) of each 8-week period.
Title
RIC's Orthotics Prosthetics User Survey
Description
Participants will complete the Upper Extremity Functional Status module from RIC's Orthotics Prosthetics User Survey (OPUS). The OPUS asks prosthetic users to rate the level of difficulty (from very easy to very difficult) in performing upper arm/hand functions using their pattern recognition device. Survey data will be evaluated using rating scale analysis (Rasch model).
Time Frame
Participants will complete the OPUS at the start (0-months) and end (2-months) of each 8-week period.
Title
Changes in virtual game performance
Description
Participants will complete a virtual game called Simon Says using the Coapt Complete ControlRoom desktop application. Simon Says is a Fitt's Law-style test that measures how well participants control each motion using their pattern recognition device by moving a virtual arm on a screen. Participants will be instructed to match and hold the position of a virtual arm in a target position for 1 second. Participants will complete each motion (either independent or simultaneous motions) 3 times. We will measure their overall performance by computing completion rate, movement time, path efficiency. We will perform a statistical analysis to compare virtual game performance when using each type of pattern recognition control. We will complete a repeated measures analysis of variance with subject as a random factor, order of control style used as a fixed variable, and each performance metric as a fixed variable.
Time Frame
Participants will complete the virtual test at the start (0-months), mid-point (1-months) and end (2-months) of each 8-week period.

10. Eligibility

Sex
All
Minimum Age & Unit of Time
18 Years
Maximum Age & Unit of Time
70 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria: Subjects have an upper-limb difference (congenital or acquired) at the transradial (between the wrist and elbow), elbow disarticulation (at the elbow), transhumeral (between the elbow and shoulder), or shoulder disarticulation (at the shoulder) level. Subjects are suitable to be, or already are, a Coapt pattern recognition user (Coapt Complete Control Gen2 device). Subjects are between the ages of 18 and 70. Exclusion Criteria: Subjects with significant cognitive deficits or visual impairment that would preclude them from giving informed consent or following instructions during the experiments, or the ability to obtain relevant user feedback discussion. Subjects who are non-English speaking. Subjects who are pregnant.
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Blair Lock, MScE
Organizational Affiliation
Coapt, LLC
Official's Role
Principal Investigator
Facility Information:
Facility Name
Coapt, LLC
City
Chicago
State/Province
Illinois
ZIP/Postal Code
60654
Country
United States

12. IPD Sharing Statement

Plan to Share IPD
Yes
IPD Sharing Plan Description
Only de-identified individual participant data collected during the study may be shared. This includes any experimental data that will underlie results in a publication such as EMG data, prosthesis usage data, virtual game data and surveys and questionnaires.
IPD Sharing Time Frame
We expect study data and results to become available at the end of the study upon completing data analysis and publication.
IPD Sharing Access Criteria
It is at the discretion of authorized study personnel with whom data will be shared or where it may be made available. Only de-identified data will be shared using standard data file formats (.csv or .txt). Data may be shared with the research community at large to advance science and health. Data will be publicly available via an online data sharing website only if required for publication in a scientific journal. Upon data analysis completion, study results may be shared with subjects and will be disseminated to the public in the form of a journal publication. Study results may also be posted on the Coapt website.
Citations:
PubMed Identifier
23366279
Citation
Chicoine CL, Simon AM, Hargrove LJ. Prosthesis-guided training of pattern recognition-controlled myoelectric prosthesis. Annu Int Conf IEEE Eng Med Biol Soc. 2012;2012:1876-9. doi: 10.1109/EMBC.2012.6346318.
Results Reference
background
PubMed Identifier
21938652
Citation
Scheme E, Englehart K. Electromyogram pattern recognition for control of powered upper-limb prostheses: state of the art and challenges for clinical use. J Rehabil Res Dev. 2011;48(6):643-59. doi: 10.1682/jrrd.2010.09.0177.
Results Reference
background
PubMed Identifier
21938650
Citation
Simon AM, Hargrove LJ, Lock BA, Kuiken TA. Target Achievement Control Test: evaluating real-time myoelectric pattern-recognition control of multifunctional upper-limb prostheses. J Rehabil Res Dev. 2011;48(6):619-27. doi: 10.1682/jrrd.2010.08.0149.
Results Reference
background
PubMed Identifier
24886664
Citation
Wurth SM, Hargrove LJ. A real-time comparison between direct control, sequential pattern recognition control and simultaneous pattern recognition control using a Fitts' law style assessment procedure. J Neuroeng Rehabil. 2014 May 30;11:91. doi: 10.1186/1743-0003-11-91.
Results Reference
background

Learn more about this trial

Pattern Recognition Prosthetic Control

We'll reach out to this number within 24 hrs