Peripheral Stimulation Device to Improve Coronary Flow Reserve in Coronary Artery Disease (PERCCAD)

Primary Purpose

Coronary Artery Disease, Ischemic Disease

Status
Completed
Phase
Phase 1
Locations
Canada
Study Type
Interventional
Intervention
gekoTM
Sponsored by
Lawson Health Research Institute
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional basic science trial for Coronary Artery Disease focused on measuring coronary artery disease, coronary flow reserve, endothelial function

Eligibility Criteria

18 Years - undefined (Adult, Older Adult)All SexesDoes not accept healthy volunteers

Inclusion Criteria:

  1. Age 18 - 80.
  2. Symptomatic coronary artery disease and already undergoing invasive angiographic assessment and percutaneous coronary intervention.

Exclusion criteria:

  1. Significant valvular heart disease or left ventricular dysfunction.
  2. Contraindication to the administration of intracoronary adenosine.
  3. Latex allergy.
  4. Significant peripheral motor neuropathy.

Sites / Locations

  • London Health Sciences Centre

Arms of the Study

Arm 1

Arm Type

Experimental

Arm Label

gekoTM device application

Arm Description

Single arm study. Application of gekoTM device as described above with assessment of effect on coronary flow and endothelial function.

Outcomes

Primary Outcome Measures

Change in Coronary Flow Reserve following stimulation with gekoTM device
The change in the effect of the gekoTM device on coronary blood flow as measured by coronary flow reserve using a Doppler tipped coronary flow wire inserted into the coronary artery tree via a percutaneous technique, will be measured at baseline, after 120 sec of stimulation with the gekoTM device on low frequency setting, and after 120 sec of stimulation with the gekoTM device on high frequency setting

Secondary Outcome Measures

Change in Popliteal artery vessel diameter following 60 mins stimulation with gekoTM device
Change in popliteal artery vessel diameter will be recorded using a surface ultrasound probe at baseline and following 60 mins of treatment with the gekoTM. This study will be performed on a separate visit following the PCI procedure.
Change in Popliteal artery vessel Doppler flow velocity following 60 mins stimulation with gekoTM device
Change in popliteal artery vessel Doppler flow velocity will be recorded using a surface ultrasound probe at baseline and following 60 mins of treatment with the gekoTM. This study will be performed on a separate visit following the PCI procedure.
Change in Endothelial function following 60 mins stimulation with gekoTM device
The change in Endothelial function study will by measured using the EndoPAT2000 following 60 mins of treatment with the gekoTM. This study will be performed on a separate visit following the PCI procedure.

Full Information

First Posted
May 8, 2013
Last Updated
November 25, 2015
Sponsor
Lawson Health Research Institute
search

1. Study Identification

Unique Protocol Identification Number
NCT01853410
Brief Title
Peripheral Stimulation Device to Improve Coronary Flow Reserve in Coronary Artery Disease
Acronym
PERCCAD
Official Title
Peripheral Stimulation Device to Improve Coronary Flow Reserve in Coronary Artery Disease
Study Type
Interventional

2. Study Status

Record Verification Date
November 2015
Overall Recruitment Status
Completed
Study Start Date
July 2013 (undefined)
Primary Completion Date
July 2014 (Actual)
Study Completion Date
October 2015 (Actual)

3. Sponsor/Collaborators

Responsible Party, by Official Title
Principal Investigator
Name of the Sponsor
Lawson Health Research Institute

4. Oversight

Data Monitoring Committee
No

5. Study Description

Brief Summary
The purpose of the PERCCAD Study is to investigate the effect of the gekoTM device (a non-invasive calf muscle stimulator approved for use to improve blood flow by Health Canada) on coronary blood flow in order to assess its potential role as a therapeutic modality for the treatment of symptomatic coronary artery disease (CAD). This will occur in patients already undergoing coronary angiography and percutaneous coronary intervention (PCI) as part of their usual medical care. Further, the investigators will also assess the overall effect on blood flow in the body using non-invasive techniques. The primary objective of the PERCCAD study is to assess the effect of the gekoTM device on coronary blood flow in patients with symptomatic CAD who are undergoing invasive angiographic assessment and management with PCI. This evaluation of the gekoTM device is to be performed at the time of the patient's already planned invasive assessment and management so that invasive data can be collected without exposing the patient to risks other than those already associated with their planned procedure and usual clinical care. The secondary objective of the study is to assess the effect of muscle stimulation with the gekoTM device on endothelial function and peripheral blood flow measured via non-invasive techniques.
Detailed Description
Angina pectoris or anginal equivalent dyspnoea are frequent symptoms related to impaired myocardial blood supply. The supply-demand imbalance that arises in the setting of coronary artery disease can be addressed by improving myocardial blood supply through mechanical revascularization with percutaneous coronary intervention or bypass surgery or by reducing myocardial energy demand through pharmacotherapy including the use of negative chronotropic agents such as beta blockers. When further revascularization is not an option, or standard therapies are insufficient to control symptoms, other novel therapies are attempted to improve myocardial blood supply and decrease angina. Enhanced external counterpulsation (EECP) devices have been demonstrated to augment cardiac performance and coronary flow and have a beneficial effect in reducing anginal symptoms in patients with CAD.(1-4) Transcutaneous (non-invasive) electrical nervous stimulation of skeletal muscle to improve venous return to the heart and provide a potential mechanism to augment and improve blood flow, including coronary flow, is a potential alternative method to achieve a similar effect,(5,6) but is less cumbersome and more easily integrated into clinical practice. The gekoTM device is a small transcutaneous nerve stimulator (weight 18g, dimensions 149mm x 42mm x 11mm) that is applied non-invasively to the skin over the common peroneal nerve in the lower limb that has been demonstrated to safely stimulate blood flow from the gastrocnemius and soleus venous system via activation of the venous 'pump' system, intrinsic to the calf muscles. As a result, the gekoTM device is approved for use in Canada to improve blood flow and is already being used in clinical practice at University Hospital. By improving venous return, this device has the potential to have a therapeutic effect in the management of CAD by augmenting coronary blood flow. The purpose of the PERCCAD Study is to investigate the effect of the gekoTM device on coronary blood flow in order to assess its potential role as a therapeutic modality for the treatment of symptomatic CAD. Further, since previous studies with EECP also demonstrated improvement in endothelial function, the investigators plan to study the effect of the gekoTM device on endothelial function and peripheral blood flow in the same patients via non invasive techniques(4, 7, 8) given the established relationship between endothelial dysfunction and cardiovascular risk. (9-12) The primary objective of the PERCCAD study is to assess the effect of the gekoTM device on coronary blood flow in patients with symptomatic CAD who are undergoing invasive angiographic assessment and management with PCI. This evaluation of the gekoTM device is to be performed at the time of the patient's already planned invasive assessment and management so that invasive data can be collected without exposing the patient to risks other than those already associated with their planned procedure and usual clinical care. The secondary objective of the study is to assess the effect of muscle stimulation with the gekoTM device on endothelial function and peripheral blood flow measured via non-invasive techniques. Study Design: Single arm clinical study where patients act as their own controls (coronary flow reserve and endothelial function measured in patients already undergoing angiography and PCI) with measurements recorded pre and post application of the gekoTM device. Coronary flow assessment: The PCI procedure will be performed according to standard practice. As part of routine practice, a guidewire is inserted into the coronary artery and used as a "rail" for delivering balloons and stents. Often, we use a special Doppler guidewire with a sensor at the tip that is used for measurements of blood flow. We will use such a guidewire for the current study (13-16). Velocity signals are obtained by the guidewire and average peak velocity (APV) is determined. Intracoronary adenosine will be given to induce hyperemia and increase coronary flow (17-21). Intracoronary adenosine is used routinely during PCI. Coronary flow reserve (CFR) will be calculated as the ratio of APV during hyperemia compared to APV at baseline. After measurement of baseline APV and CFR, we will perform two minutes of muscle stimulation using the gekoTM device at a low pulse width setting and record APV. After this, a further two minutes of muscle stimulation using the gekoTM device at a higher pulse width setting will occur with repeated APV and CFR measurements recorded. This process will be performed in at least two coronary arteries at the time of patient's usual invasive assessment and management. Calf muscle stimulation with the gekoTM device: The gekoTM device will be fitted bilaterally behind the patient's knees in the popliteal fossa. At the appropriate time the device will be set to stimulate the common peroneal nerve transcutaneously (the low setting will be set at the level at which the patient has a sensation of stimulation but where there is no visible movement of the lower leg; the high setting will be at the patient's highest tolerable level, but not lower than the level which elicited slight visible movement of the lower leg). Endothelial Function Assessment: Endothelial function study will be performed on a separate visit following the PCI, by measurement of peripheral vasodilator response using fingertip pulse amplitude tonometry (peripheral arterial tonometry-PAT). PAT signals will be obtained with the EndoPAT2000 (EndoPAT) device (Itamar Medical Inc., Caesarea, Israel). The EndoPAT is an FDA approved device for noninvasive assessment of endothelial dysfunction, it is widely used for clinical and research purposes and validated as a method of endothelial function assessment.(22-24) Specially designed finger probes are placed on the index finger of each patient's hand. The probes are comprised of a system of inflatable latex air cuffs connected by pneumatic tubes to an inflating device controlled through a computer algorithm. There is no occlusion of arterial blood flow. Pulsatile volume changes of the distal digit induce pressure alterations in the finger cuff, which are sensed by pressure transducers and transmitted to and recorded by the EndoPAT. Endothelial function is measured via a reactive hyperemia-peripheral arterial tonometry index (RH-PAT index). A reactive hyperemia protocol consists of a 5-minute baseline measurement, after which a blood pressure cuff placed on the test arm is inflated to 60 mmHg above baseline systolic blood pressure, or at least 200 mmHg for 5 minutes. After 5 minutes, the cuff is deflated, and the PAT tracing recorded for a further 5 minutes. The ratio of the PAT signal after cuff release, compared to baseline, is calculated through a computer algorithm automatically normalizing for baseline signal, and indexed to the contra lateral arm. The calculated ratio reflects the RH-PAT index, a reflection of degree of endothelial function. This process is non-invasive and does not require percutaneous vascular access. Endothelial function will also be assessed at baseline and following 1 hour treatment with the gekoTM using the EndoPAT to calculate the RH-PAT index as described. In addition, the effect on popliteal artery vessel diameter and Doppler flow velocity will also be recorded using a surface ultrasound probe at baseline and following 1 hour of treatment with the gekoTM.

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Coronary Artery Disease, Ischemic Disease
Keywords
coronary artery disease, coronary flow reserve, endothelial function

7. Study Design

Primary Purpose
Basic Science
Study Phase
Phase 1
Interventional Study Model
Single Group Assignment
Masking
None (Open Label)
Allocation
N/A
Enrollment
10 (Actual)

8. Arms, Groups, and Interventions

Arm Title
gekoTM device application
Arm Type
Experimental
Arm Description
Single arm study. Application of gekoTM device as described above with assessment of effect on coronary flow and endothelial function.
Intervention Type
Device
Intervention Name(s)
gekoTM
Primary Outcome Measure Information:
Title
Change in Coronary Flow Reserve following stimulation with gekoTM device
Description
The change in the effect of the gekoTM device on coronary blood flow as measured by coronary flow reserve using a Doppler tipped coronary flow wire inserted into the coronary artery tree via a percutaneous technique, will be measured at baseline, after 120 sec of stimulation with the gekoTM device on low frequency setting, and after 120 sec of stimulation with the gekoTM device on high frequency setting
Time Frame
Time = 0; Time = post 120 sec stimulation (low setting); Time = post 120 sec stimulation (high setting)
Secondary Outcome Measure Information:
Title
Change in Popliteal artery vessel diameter following 60 mins stimulation with gekoTM device
Description
Change in popliteal artery vessel diameter will be recorded using a surface ultrasound probe at baseline and following 60 mins of treatment with the gekoTM. This study will be performed on a separate visit following the PCI procedure.
Time Frame
Time = 0; Time = post 60 mins stimulation with gekoTM device
Title
Change in Popliteal artery vessel Doppler flow velocity following 60 mins stimulation with gekoTM device
Description
Change in popliteal artery vessel Doppler flow velocity will be recorded using a surface ultrasound probe at baseline and following 60 mins of treatment with the gekoTM. This study will be performed on a separate visit following the PCI procedure.
Time Frame
Time = 0; Time = post 60 mins stimulation with gekoTM device
Title
Change in Endothelial function following 60 mins stimulation with gekoTM device
Description
The change in Endothelial function study will by measured using the EndoPAT2000 following 60 mins of treatment with the gekoTM. This study will be performed on a separate visit following the PCI procedure.
Time Frame
Time = 0; Time = post 60 mins stimulation with gekoTM device

10. Eligibility

Sex
All
Minimum Age & Unit of Time
18 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria: Age 18 - 80. Symptomatic coronary artery disease and already undergoing invasive angiographic assessment and percutaneous coronary intervention. Exclusion criteria: Significant valvular heart disease or left ventricular dysfunction. Contraindication to the administration of intracoronary adenosine. Latex allergy. Significant peripheral motor neuropathy.
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Shahar Lavi, MD
Organizational Affiliation
London Health Sciences Centre
Official's Role
Principal Investigator
Facility Information:
Facility Name
London Health Sciences Centre
City
London
State/Province
Ontario
ZIP/Postal Code
N6A5A5
Country
Canada

12. IPD Sharing Statement

Citations:
PubMed Identifier
18404725
Citation
Loh PH, Cleland JG, Louis AA, Kennard ED, Cook JF, Caplin JL, Barsness GW, Lawson WE, Soran OZ, Michaels AD. Enhanced external counterpulsation in the treatment of chronic refractory angina: a long-term follow-up outcome from the International Enhanced External Counterpulsation Patient Registry. Clin Cardiol. 2008 Apr;31(4):159-64. doi: 10.1002/clc.20117.
Results Reference
background
PubMed Identifier
11482918
Citation
Masuda D, Nohara R, Hirai T, Kataoka K, Chen LG, Hosokawa R, Inubushi M, Tadamura E, Fujita M, Sasayama S. Enhanced external counterpulsation improved myocardial perfusion and coronary flow reserve in patients with chronic stable angina; evaluation by(13)N-ammonia positron emission tomography. Eur Heart J. 2001 Aug;22(16):1451-8. doi: 10.1053/euhj.2000.2545.
Results Reference
background
PubMed Identifier
12208799
Citation
Michaels AD, Accad M, Ports TA, Grossman W. Left ventricular systolic unloading and augmentation of intracoronary pressure and Doppler flow during enhanced external counterpulsation. Circulation. 2002 Sep 3;106(10):1237-42. doi: 10.1161/01.cir.0000028336.95629.b0.
Results Reference
background
PubMed Identifier
22560950
Citation
Yang DY, Wu GF. Vasculoprotective properties of enhanced external counterpulsation for coronary artery disease: beyond the hemodynamics. Int J Cardiol. 2013 Jun 5;166(1):38-43. doi: 10.1016/j.ijcard.2012.04.003. Epub 2012 May 4.
Results Reference
background
Citation
Jawad H. The effect of a novel electrical stimulation method for improving lower limb blood flow in healthy volunteers. 2012
Results Reference
background
PubMed Identifier
22477572
Citation
Tucker A, Maass A, Bain D, Chen LH, Azzam M, Dawson H, Johnston A. Augmentation of venous, arterial and microvascular blood supply in the leg by isometric neuromuscular stimulation via the peroneal nerve. Int J Angiol. 2010 Spring;19(1):e31-7. doi: 10.1055/s-0031-1278361.
Results Reference
background
PubMed Identifier
16784915
Citation
Akhtar M, Wu GF, Du ZM, Zheng ZS, Michaels AD. Effect of external counterpulsation on plasma nitric oxide and endothelin-1 levels. Am J Cardiol. 2006 Jul 1;98(1):28-30. doi: 10.1016/j.amjcard.2006.01.053. Epub 2006 May 3.
Results Reference
background
PubMed Identifier
12767662
Citation
Bonetti PO, Barsness GW, Keelan PC, Schnell TI, Pumper GM, Kuvin JT, Schnall RP, Holmes DR, Higano ST, Lerman A. Enhanced external counterpulsation improves endothelial function in patients with symptomatic coronary artery disease. J Am Coll Cardiol. 2003 May 21;41(10):1761-8. doi: 10.1016/s0735-1097(03)00329-2.
Results Reference
background
PubMed Identifier
20181680
Citation
Rubinshtein R, Kuvin JT, Soffler M, Lennon RJ, Lavi S, Nelson RE, Pumper GM, Lerman LO, Lerman A. Assessment of endothelial function by non-invasive peripheral arterial tonometry predicts late cardiovascular adverse events. Eur Heart J. 2010 May;31(9):1142-8. doi: 10.1093/eurheartj/ehq010. Epub 2010 Feb 24.
Results Reference
background
PubMed Identifier
11927524
Citation
Gokce N, Keaney JF Jr, Hunter LM, Watkins MT, Menzoian JO, Vita JA. Risk stratification for postoperative cardiovascular events via noninvasive assessment of endothelial function: a prospective study. Circulation. 2002 Apr 2;105(13):1567-72. doi: 10.1161/01.cir.0000012543.55874.47.
Results Reference
background
PubMed Identifier
15582310
Citation
Bonetti PO, Pumper GM, Higano ST, Holmes DR Jr, Kuvin JT, Lerman A. Noninvasive identification of patients with early coronary atherosclerosis by assessment of digital reactive hyperemia. J Am Coll Cardiol. 2004 Dec 7;44(11):2137-41. doi: 10.1016/j.jacc.2004.08.062.
Results Reference
background
PubMed Identifier
18458169
Citation
Hamburg NM, Keyes MJ, Larson MG, Vasan RS, Schnabel R, Pryde MM, Mitchell GF, Sheffy J, Vita JA, Benjamin EJ. Cross-sectional relations of digital vascular function to cardiovascular risk factors in the Framingham Heart Study. Circulation. 2008 May 13;117(19):2467-74. doi: 10.1161/CIRCULATIONAHA.107.748574. Epub 2008 May 5.
Results Reference
background
PubMed Identifier
4835753
Citation
Gould KL, Lipscomb K. Effects of coronary stenoses on coronary flow reserve and resistance. Am J Cardiol. 1974 Jul;34(1):48-55. doi: 10.1016/0002-9149(74)90092-7. No abstract available.
Results Reference
background
PubMed Identifier
6234109
Citation
Hoffman JI. Maximal coronary flow and the concept of coronary vascular reserve. Circulation. 1984 Aug;70(2):153-9. doi: 10.1161/01.cir.70.2.153. No abstract available.
Results Reference
background
PubMed Identifier
8489855
Citation
Collins P. Coronary flow reserve. Br Heart J. 1993 Apr;69(4):279-81. doi: 10.1136/hrt.69.4.279. No abstract available.
Results Reference
background
PubMed Identifier
2964950
Citation
Wilson RF, Johnson MR, Marcus ML, Aylward PE, Skorton DJ, Collins S, White CW. The effect of coronary angioplasty on coronary flow reserve. Circulation. 1988 Apr;77(4):873-85. doi: 10.1161/01.cir.77.4.873.
Results Reference
background
PubMed Identifier
8124786
Citation
De Bruyne B, Baudhuin T, Melin JA, Pijls NH, Sys SU, Bol A, Paulus WJ, Heyndrickx GR, Wijns W. Coronary flow reserve calculated from pressure measurements in humans. Validation with positron emission tomography. Circulation. 1994 Mar;89(3):1013-22. doi: 10.1161/01.cir.89.3.1013.
Results Reference
background
PubMed Identifier
15459587
Citation
Casella G, Leibig M, Schiele TM, Schrepf R, Seelig V, Stempfle HU, Erdin P, Rieber J, Konig A, Siebert U, Klauss V. Are high doses of intracoronary adenosine an alternative to standard intravenous adenosine for the assessment of fractional flow reserve? Am Heart J. 2004 Oct;148(4):590-5. doi: 10.1016/j.ahj.2004.04.008.
Results Reference
background
PubMed Identifier
12851614
Citation
Murtagh B, Higano S, Lennon R, Mathew V, Holmes DR Jr, Lerman A. Role of incremental doses of intracoronary adenosine for fractional flow reserve assessment. Am Heart J. 2003 Jul;146(1):99-105. doi: 10.1016/S0002-8703(03)00120-0.
Results Reference
background
PubMed Identifier
11011341
Citation
Jeremias A, Whitbourn RJ, Filardo SD, Fitzgerald PJ, Cohen DJ, Tuzcu EM, Anderson WD, Abizaid AA, Mintz GS, Yeung AC, Kern MJ, Yock PG. Adequacy of intracoronary versus intravenous adenosine-induced maximal coronary hyperemia for fractional flow reserve measurements. Am Heart J. 2000 Oct;140(4):651-7. doi: 10.1067/mhj.2000.109920.
Results Reference
background
PubMed Identifier
3180211
Citation
Zijlstra F, Juilliere Y, Serruys PW, Roelandt JR. Value and limitations of intracoronary adenosine for the assessment of coronary flow reserve. Cathet Cardiovasc Diagn. 1988;15(2):76-80. doi: 10.1002/ccd.1810150203.
Results Reference
background
PubMed Identifier
12851627
Citation
Kuvin JT, Patel AR, Sliney KA, Pandian NG, Sheffy J, Schnall RP, Karas RH, Udelson JE. Assessment of peripheral vascular endothelial function with finger arterial pulse wave amplitude. Am Heart J. 2003 Jul;146(1):168-74. doi: 10.1016/S0002-8703(03)00094-2.
Results Reference
background
PubMed Identifier
17451088
Citation
Kuvin JT, Mammen A, Mooney P, Alsheikh-Ali AA, Karas RH. Assessment of peripheral vascular endothelial function in the ambulatory setting. Vasc Med. 2007 Feb;12(1):13-6. doi: 10.1177/1358863X06076227.
Results Reference
background
PubMed Identifier
19467447
Citation
Hamburg NM, Benjamin EJ. Assessment of endothelial function using digital pulse amplitude tonometry. Trends Cardiovasc Med. 2009 Jan;19(1):6-11. doi: 10.1016/j.tcm.2009.03.001.
Results Reference
background

Learn more about this trial

Peripheral Stimulation Device to Improve Coronary Flow Reserve in Coronary Artery Disease

We'll reach out to this number within 24 hrs