search
Back to results

Respiratory Protection Effect of Ear-loop-type KF94 Mask

Primary Purpose

Infection

Status
Completed
Phase
Not Applicable
Locations
Korea, Republic of
Study Type
Interventional
Intervention
tight-fitting of KF94 mask with clip
Sponsored by
Samsung Medical Center
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional prevention trial for Infection focused on measuring Respiratory protective devices, quantitative fit test, N95 filtering facepiece respirators, infection control, KF94 mask

Eligibility Criteria

18 Years - 65 Years (Adult, Older Adult)All SexesAccepts Healthy Volunteers

Inclusion Criteria:

  • healthcare workers with experience in wearing filtering facepiece respirator working in the hospital

Exclusion Criteria:

  • Individuals with expected difficulties in wearing masks or undergoing OSHA fit tests because of factors such as a facial anomaly, lung disease, or lower back disorder

Sites / Locations

  • Samsung Medical Center

Arms of the Study

Arm 1

Arm 2

Arm 3

Arm Type

Experimental

Experimental

Experimental

Arm Label

Group A

Group B

Group C

Arm Description

Participants were randomly assigned to groups A, B, and C to reduce learning effects according to the mask type

Participants were randomly assigned to groups A, B, and C to reduce learning effects according to the mask type

Participants were randomly assigned to groups A, B, and C to reduce learning effects according to the mask type

Outcomes

Primary Outcome Measures

total fit factors(FFs) of the quantitative fit tests (QNFT) according to the wearing method of the three types of KF94 masks

Secondary Outcome Measures

passing rate of the QNFT according to the wearing method
total FFs after user-seal-check and real-time adjustment

Full Information

First Posted
March 8, 2021
Last Updated
March 12, 2021
Sponsor
Samsung Medical Center
search

1. Study Identification

Unique Protocol Identification Number
NCT04794556
Brief Title
Respiratory Protection Effect of Ear-loop-type KF94 Mask
Official Title
Respiratory Protection Effect of Ear-loop-type KF94 Filtering Facepiece Respirators According to the Wearing Method: A Randomized, Open-label Study
Study Type
Interventional

2. Study Status

Record Verification Date
March 2021
Overall Recruitment Status
Completed
Study Start Date
January 1, 2021 (Actual)
Primary Completion Date
March 10, 2021 (Actual)
Study Completion Date
March 10, 2021 (Actual)

3. Sponsor/Collaborators

Responsible Party, by Official Title
Principal Investigator
Name of the Sponsor
Samsung Medical Center

4. Oversight

Studies a U.S. FDA-regulated Drug Product
No
Studies a U.S. FDA-regulated Device Product
No
Data Monitoring Committee
No

5. Study Description

Brief Summary
Ear-loop-type Korean Filter 94 masks (KF94 masks, equivalent to the N95 and FFP2) are broadly used in health care settings in Korea for the COVID-19 pandemic. However, no studies have assessed the adequacy of respiratory protection. In this prospective randomized open-label study, the investigators aimed to evaluate the fitting performance of ear-loop-type KF94 masks by the quantitative fit test according to the occupational safety and health administration (OSHA) protocol. In addition, by quantitatively comparing the "tight-fitting" method using a clip and the "general-fitting" method, the investigators tried to evaluate whether the tight-wearing method improves the fitting performance of KF94 masks.
Detailed Description
Sample size: The sample size was calculated based on a pilot study of 10 participants, which examined the FF of general-fitting. The mean FF was 20.3, and the log-transformed FFs were assessed due to skewed data, which was 1.98 (standard deviation 1.34). We assumed that the FF for tight-fitting would increase by 50%, with an α value of .05, and a β error of .10 (power = 90%) for two-sided hypothesis testing. The estimated sample size calculation revealed a required sample of 24 participants. Therefore, 30 participants were enrolled to account for a 20% dropout rate. Data analyses: Repeated-measures analysis of variance or generalized estimating equations were used to compare the FFs or passing rate of the QNFTs for the three mask types according to the wearing method. Paired t-tests or Wilcoxon signed-rank tests were used to compare the FFs according to the wearing method for each mask type. McNemar's test was used to compare the passing rate of the QNFT according to the wearing method. Bonferroni's correction was performed for all results of each subgroup analysis. SAS ver. 9.4 software (SAS Institute, Cary, NC) was used to perform all statistical analyses.

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Infection
Keywords
Respiratory protective devices, quantitative fit test, N95 filtering facepiece respirators, infection control, KF94 mask

7. Study Design

Primary Purpose
Prevention
Study Phase
Not Applicable
Interventional Study Model
Parallel Assignment
Masking
None (Open Label)
Allocation
Randomized
Enrollment
30 (Actual)

8. Arms, Groups, and Interventions

Arm Title
Group A
Arm Type
Experimental
Arm Description
Participants were randomly assigned to groups A, B, and C to reduce learning effects according to the mask type
Arm Title
Group B
Arm Type
Experimental
Arm Description
Participants were randomly assigned to groups A, B, and C to reduce learning effects according to the mask type
Arm Title
Group C
Arm Type
Experimental
Arm Description
Participants were randomly assigned to groups A, B, and C to reduce learning effects according to the mask type
Intervention Type
Device
Intervention Name(s)
tight-fitting of KF94 mask with clip
Intervention Description
The general-fitting method involved wearing a mask with ear loops, and the tight-fitting method involved wearing a clip that connected ear loops on the occiput after wearing a mask according to the general method
Primary Outcome Measure Information:
Title
total fit factors(FFs) of the quantitative fit tests (QNFT) according to the wearing method of the three types of KF94 masks
Time Frame
through study completion, an average of 1 year
Secondary Outcome Measure Information:
Title
passing rate of the QNFT according to the wearing method
Time Frame
through study completion, an average of 1 year
Title
total FFs after user-seal-check and real-time adjustment
Time Frame
through study completion, an average of 1 year

10. Eligibility

Sex
All
Minimum Age & Unit of Time
18 Years
Maximum Age & Unit of Time
65 Years
Accepts Healthy Volunteers
Accepts Healthy Volunteers
Eligibility Criteria
Inclusion Criteria: healthcare workers with experience in wearing filtering facepiece respirator working in the hospital Exclusion Criteria: Individuals with expected difficulties in wearing masks or undergoing OSHA fit tests because of factors such as a facial anomaly, lung disease, or lower back disorder
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Hee Yoon, MD., PhD.
Organizational Affiliation
Samsung Medical Center
Official's Role
Study Director
Facility Information:
Facility Name
Samsung Medical Center
City
Seoul
ZIP/Postal Code
06351
Country
Korea, Republic of

12. IPD Sharing Statement

Plan to Share IPD
No
Citations:
PubMed Identifier
34282608
Citation
Yang HJ, Yoon H, Kang SY, Lee G, Park JE, Kim T, Lee SU, Hwang SY, Cha WC, Shin TG, Jo IJ. Respiratory Protection Effect of Ear-loop-type KF94 Masks according to the Wearing Method in COVID-19 Pandemic: a Randomized, Open-label Study. J Korean Med Sci. 2021 Jul 19;36(28):e209. doi: 10.3346/jkms.2021.36.e209.
Results Reference
derived

Learn more about this trial

Respiratory Protection Effect of Ear-loop-type KF94 Mask

We'll reach out to this number within 24 hrs