Right Ventricular (RV) Pacing in Early Post-operative Continuous Flow Left Ventricular Assist Device (LVAD)

Primary Purpose

Heart Failure

Status
Terminated
Phase
Phase 4
Locations
United States
Study Type
Interventional
Intervention
Implantable Cardioverter-Defibrillator (subject's pre-existing ICD)
Implantable Cardioverter-Defibrillator (subject's pre-existing ICD)
Sponsored by
Duke University
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional prevention trial for Heart Failure focused on measuring Ventricular assist device

Eligibility Criteria

18 Years - undefined (Adult, Older Adult)All SexesDoes not accept healthy volunteers

Inclusion Criteria:

  • Age ≥ 18 years old, both men and women
  • Existing implantable cardioverter-defibrillator (ICD)
  • Referred for implantation of a continuous flow LVAD

Exclusion Criteria:

  • Permanent left ventricular epicardial defibrillator in place
  • Congenital heart disease with single ventricle physiology
  • Right ventricular assist device (RVAD) in place
  • Existing pacing indication

Sites / Locations

  • Duke University Medical Center

Arms of the Study

Arm 1

Arm 2

Arm Type

Placebo Comparator

Experimental

Arm Label

Native Conduction

Continuous RV Pacing

Arm Description

Devices will be programmed to continuous atrial pacing at an AAI (atrial inhibited pacing) setting with base rate 90 bpm. Patients will not receive ventricular pacing.

Devices will be programmed to continuous dual chamber pacing at a DDD (dual chamber dual pacing) setting with base rate ≥ 90 bpm (not to exceed 100 bpm) to achieve a majority (>80%) of paced right ventricular beats

Outcomes

Primary Outcome Measures

Length of Hospitalization
To determine whether continuous RV pacing reduces ICU length of stay (number of days) and overall hospital length of stay (number of days) post-LVAD implantation.

Secondary Outcome Measures

Post-operative Need for Hemodynamic / Respiratory Support
To determine whether continuous RV pacing reduces the need for inotropic / vasoactive agents, mechanical ventilation, or other circulatory support in the early post-operative period. Measured by the number of hemodynamic and respiratory support interventions and duration of those interventions.
Right Ventricular Function
To determine whether continuous RV pacing improves invasive and non-invasive measures of RV function in the early period post-LVAD implantation. Measured by Pulmonary Artery catheter measures of intra-cardiac pressures and cardiac output in the ICU setting and by qualitative and quantitative Echocardiographic measures of RV function during the hospital course.
Functional Capacity and Symptoms
To determine whether continuous RV pacing improves functional capacity and symptoms as measured by six minute walk test and symptoms questionnaires in the early post-LVAD implantation period.

Full Information

First Posted
September 14, 2011
Last Updated
February 19, 2015
Sponsor
Duke University
Collaborators
Medtronic
search

1. Study Identification

Unique Protocol Identification Number
NCT01446796
Brief Title
Right Ventricular (RV) Pacing in Early Post-operative Continuous Flow Left Ventricular Assist Device (LVAD)
Official Title
Hemodynamic and Clinical Effects of Continuous Right Ventricular Pacing in the Early Post-operative Period After Left Ventricular Assist Device Implantation
Study Type
Interventional

2. Study Status

Record Verification Date
February 2015
Overall Recruitment Status
Terminated
Why Stopped
Recruitment futility
Study Start Date
September 2011 (undefined)
Primary Completion Date
May 2012 (Actual)
Study Completion Date
October 2012 (Actual)

3. Sponsor/Collaborators

Responsible Party, by Official Title
Sponsor
Name of the Sponsor
Duke University
Collaborators
Medtronic

4. Oversight

Data Monitoring Committee
Yes

5. Study Description

Brief Summary
Continuous right ventricular (RV) pacing demonstrates harm in patients with normal left ventricular (LV) function as well as in patients with cardiomyopathy and clinical heart failure. However, little is known about RV pacing in patients with advanced heart failure treated with an implantable left ventricular assist device (LVAD). The univentricular support provided by contemporary continuous flow LVAD's has improved outcomes for many advanced heart failure patients, yet the incidence of RV failure in the early post-operative period following implantation is associated with significantly reduced survival and increased length of stay. Acute LVAD unloading of the left ventricle has adverse effects on RV shape and size that contribute to post-operative RV failure. By promoting RV synchrony, RV overdrive pacing may counteract these adverse mechanical alterations, improving RV systolic function and ultimately LVAD function. The investigators will recruit all patients referred for an implantable, continuous flow LVAD at Duke University Medical Center who have an existing implantable dual-chamber cardioverter-defibrillator. Patients will be prospectively randomized into two cohorts to compare continuous right ventricular pacing vs. native ventricular conduction at equivalent heart rates. Multiple clinical outcomes will be examined over a two week period post-operatively including invasive hemodynamics, vasoactive medication use, end-organ function, RV function by Echocardiography as well as patient symptoms and functional status.

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Heart Failure
Keywords
Ventricular assist device

7. Study Design

Primary Purpose
Prevention
Study Phase
Phase 4
Interventional Study Model
Parallel Assignment
Masking
Participant
Allocation
Randomized
Enrollment
3 (Actual)

8. Arms, Groups, and Interventions

Arm Title
Native Conduction
Arm Type
Placebo Comparator
Arm Description
Devices will be programmed to continuous atrial pacing at an AAI (atrial inhibited pacing) setting with base rate 90 bpm. Patients will not receive ventricular pacing.
Arm Title
Continuous RV Pacing
Arm Type
Experimental
Arm Description
Devices will be programmed to continuous dual chamber pacing at a DDD (dual chamber dual pacing) setting with base rate ≥ 90 bpm (not to exceed 100 bpm) to achieve a majority (>80%) of paced right ventricular beats
Intervention Type
Device
Intervention Name(s)
Implantable Cardioverter-Defibrillator (subject's pre-existing ICD)
Intervention Description
Pacing parameters set to AAI 90
Intervention Type
Device
Intervention Name(s)
Implantable Cardioverter-Defibrillator (subject's pre-existing ICD)
Intervention Description
Pacing parameters set to DDD 90-100
Primary Outcome Measure Information:
Title
Length of Hospitalization
Description
To determine whether continuous RV pacing reduces ICU length of stay (number of days) and overall hospital length of stay (number of days) post-LVAD implantation.
Time Frame
14 days
Secondary Outcome Measure Information:
Title
Post-operative Need for Hemodynamic / Respiratory Support
Description
To determine whether continuous RV pacing reduces the need for inotropic / vasoactive agents, mechanical ventilation, or other circulatory support in the early post-operative period. Measured by the number of hemodynamic and respiratory support interventions and duration of those interventions.
Time Frame
14 days
Title
Right Ventricular Function
Description
To determine whether continuous RV pacing improves invasive and non-invasive measures of RV function in the early period post-LVAD implantation. Measured by Pulmonary Artery catheter measures of intra-cardiac pressures and cardiac output in the ICU setting and by qualitative and quantitative Echocardiographic measures of RV function during the hospital course.
Time Frame
14 days
Title
Functional Capacity and Symptoms
Description
To determine whether continuous RV pacing improves functional capacity and symptoms as measured by six minute walk test and symptoms questionnaires in the early post-LVAD implantation period.
Time Frame
14 days

10. Eligibility

Sex
All
Minimum Age & Unit of Time
18 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria: Age ≥ 18 years old, both men and women Existing implantable cardioverter-defibrillator (ICD) Referred for implantation of a continuous flow LVAD Exclusion Criteria: Permanent left ventricular epicardial defibrillator in place Congenital heart disease with single ventricle physiology Right ventricular assist device (RVAD) in place Existing pacing indication
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Joseph Rogers, MD
Organizational Affiliation
Duke University
Official's Role
Principal Investigator
Facility Information:
Facility Name
Duke University Medical Center
City
Durham
State/Province
North Carolina
ZIP/Postal Code
27710
Country
United States

12. IPD Sharing Statement