search
Back to results

Robotized Navigation Compared to Conventional Technique in Total Knee Replacement (NavioRCT)

Primary Purpose

Arthritis, Degenerative, Osteo Arthritis Knee

Status
Active
Phase
Not Applicable
Locations
Norway
Study Type
Interventional
Intervention
Navio
Conventional
Sponsored by
Haukeland University Hospital
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional treatment trial for Arthritis, Degenerative

Eligibility Criteria

45 Years - 85 Years (Adult, Older Adult)All SexesDoes not accept healthy volunteers

Inclusion Criteria:

  • Degenerative knee in need of a total knee arthroplasty
  • Recruited from the hospital's waiting list
  • Informed consent

Exclusion Criteria:

  • Severe systemic illness
  • Infections
  • Severe neurological dysfunction
  • Severe cancer disease
  • Severe incompensated heart failure
  • Severe incompensated lung disease
  • Dementia
  • Previous fracture or deformity of the limb, making the use of an intramedullary rod impossible (same side hip or ankle implant is not to be excluded if the rod unaffectedly reaches more than the first half of the femoral canal)

Sites / Locations

  • Haukeland university hospital
  • Haugesund sanitetsforenings revmatismesykehus

Arms of the Study

Arm 1

Arm 2

Arm Type

Experimental

Active Comparator

Arm Label

Navio

Conventional

Arm Description

Using the new technology during surgery

Using the conventional surgical instruments

Outcomes

Primary Outcome Measures

Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) high responders
Difference in rate (0.00-1.00) of high responders (calculated from KOOS)
WOMAC high responders
Difference in rate (0.00-1.00) of high responders (calculated from KOOS)
WOMAC high responders
Difference in rate (0.00-1.00) of high responders (calculated from KOOS)
WOMAC high responders
Difference in rate (0.00-1.00) of high responders (calculated from KOOS)
Radiostereometric migration
Maximum total point of motion MTPM (millimeters), (includes only first 60 patients)
Radiostereometric migration
Maximum total point of motion MTPM (millimeters), (includes only first 60 patients)
Radiostereometric migration
Maximum total point of motion MTPM (millimeters), (includes only first 60 patients)

Secondary Outcome Measures

Knee injury and osteoarthritis outcome score (KOOS)
Symptoms, Stiffness, Pain, Activity of daily living, Sports, Quality of life subscores (0(worse)-100(better))
Knee injury and osteoarthritis outcome score (KOOS)
Symptoms, Stiffness, Pain, Activity of daily living, Sports, Quality of life subscores (0-100)
Knee injury and osteoarthritis outcome score (KOOS)
Symptoms, Stiffness, Pain, Activity of daily living, Sports, Quality of life subscores (0-100)
Knee injury and osteoarthritis outcome score (KOOS)
Symptoms, Stiffness, Pain, Activity of daily living, Sports, Quality of life subscores (0-100)
Knee society score (KSS)
Knee society score, knee score (0(worse)-100(better)) and function score (0(worse)-100(better))
Knee society score (KSS)
Knee society score, knee score (0-100) and function score (0-100)
Knee society score (KSS)
Knee society score, knee score (0-100) and function score (0-100)
Knee society score (KSS)
Knee society score, knee score (0-100) and function score (0-100)
EQ-5D
Euroqol, quality of life (0(worse)-100(better))
EQ-5D
Euroqol, quality of life (0-100)
EQ-5D
Euroqol, quality of life (0-100)
EQ-5D
Euroqol, quality of life (0-100)
Visual analogue scale (VAS)
Visual Analogue Scale pain (0(worse)-100(better))
Forgotten Joint Score (FJS)
Forgotten Joint Score (0(worse)-100(better))
Forgotten Joint Score (FJS)
Forgotten Joint Score (0-100)
Forgotten Joint Score (FJS)
Forgotten Joint Score (0-100)
Forgotten Joint Score (FJS)
Forgotten Joint Score (0-100)
Maximum climb-up test
Height (cm) of one stair climbed with affected/operated limb (no pulling by hands)
Maximum climb-up test
Height (cm) of one stair climbed with affected/operated limb (no pulling by hands)
Anchor questions
Are you satisfied with the outcome? Would you do it again?
Anchor questions
Are you satisfied with the outcome? Would you do it again?
Timed 40 meters walking test
Time spent walking 40 meters
Timed 40 meters walking test
Time spent (in seconds) walking 40 meters
Chair test 30 seconds
number of repetitions from sitting to standing position during 30 seconds
Chair test 30 seconds
number of repetitions from sitting to standing position during 30 seconds

Full Information

First Posted
August 17, 2020
Last Updated
September 27, 2023
Sponsor
Haukeland University Hospital
Collaborators
University of Bergen, Haugesund Rheumatism Hospital
search

1. Study Identification

Unique Protocol Identification Number
NCT04525950
Brief Title
Robotized Navigation Compared to Conventional Technique in Total Knee Replacement
Acronym
NavioRCT
Official Title
Robotized Computer Navigation Versus Conventional Technique in Total Knee Replacement. A Randomized, Clinical and Radiostereometric Trial.
Study Type
Interventional

2. Study Status

Record Verification Date
March 2023
Overall Recruitment Status
Active, not recruiting
Study Start Date
September 7, 2020 (Actual)
Primary Completion Date
May 1, 2023 (Actual)
Study Completion Date
December 31, 2031 (Anticipated)

3. Sponsor/Collaborators

Responsible Party, by Official Title
Sponsor
Name of the Sponsor
Haukeland University Hospital
Collaborators
University of Bergen, Haugesund Rheumatism Hospital

4. Oversight

Studies a U.S. FDA-regulated Drug Product
No
Studies a U.S. FDA-regulated Device Product
No
Data Monitoring Committee
No

5. Study Description

Brief Summary
Navio is a new generation of computer navigation systems allowing intraoperative navigation of the bone cuts relative to both ligaments and skeletal axes, prior to bone removal. An improved accuracy is incorporated by the use of robotics in a burr for bone removal. This study investigates whether this advanced technology leads to better clinical or radiostereometric results, by comparing one group operated with Navio to another group operated with conventional technique.
Detailed Description
Background: The scientific foundation of total knee replacement (TKR) surgery is incomplete. As a national governor of joint replacements, the Norwegian Arthroplasty Register is obligated to strict regulations, demanding high levels of evidence for implants and instruments utilized by Norwegian surgeons. It is well known that 15-20% of patients with a TKR, are dissatisfied. Nevertheless, only a small proportion of these patients have revision surgery. In this randomized, clinical trial we will use the Journey II BCS total knee system, with a more native anatomical design, intended to improve the kinematics and functional outcomes by mimicking a native knee, with respect to geometry and its interplay with the ligaments and soft tissue envelope of the knee (i.e. the biomechanics; stability, joint line, off-set, sizing etc.). To achieve an optimal placement of the implant, the surgeon needs to assess a lot of information (experience) during the surgical procedure. To secure this process, and to make sure all aspects are taken into account, with respect to an optimal positioning and ligament balancing, the computer navigation technique may offer valuable input, with further enhancement of the accuracy and precision using precision tools like the Navio from Smith & Nephew. The Navio system combines robotics and computer navigation, and represents the newest technology within surgical robotics and haptics. This trial is important in the mandatory evaluation process needed, before introducing new technology into orthopaedic surgery, on a larger scale. Methods: The surgeons involved have been trained at a wet lab, and on saw bones, before utilizing this tool in a live setting. After the introduction period, the training will continue in a clinical setting until the surgeons have operated at least 20 Navio assisted cases each, followed by a pilot study of 10 patients. All patients will be randomized to either Navio or Conventional technique. Surgical method: A tourniquet is used. All implant components are cemented (Palacos R+G bone cement is utilized 10 minutes after retrieval from a 4 degrees Celsius refrigerator). Standard para-patellar approach. ACL and PCL are removed. Closing of the wound and capsule in mid-flexion position, Quill for the capsule, Vicryl for the subcutaneous tissue, continuous overlapping mattress with Ethilon suture for the skin. No drainage. Wrapping of the entire limb with elastic dressings for the first 48 hours. Prophylactic antibiotics and anticoagulants are given. Tranexamic acid to reduce bleeding. Postop pain medication: gabapentin, acetaminophen, naproxen, femoral triangle nerve block (repeated next day if needed). For the conventional group: The rotational alignment is set according to Whiteside's line, and intramedullary rods with 5, 6 or 7 degrees valgus, are selected for the distal femoral cut (dependent on pre-operatively measured angles on long radiographs (hip-knee-ankle). The entry hole of the rod is plugged with bone from the femur to reduce bleeding from the intramedullary canal. The tibial component (metal) is positioned with a 3 degrees posterior slope. For the Navio group: The cuts are navigated to optimize ligament balance in flexion and extension, and adjusted for mid-flexion instability when needed. A difference of less than 4 mm between lateral and medial gaps is accepted when the laxity is on the lateral side, preferably in flexion. However, if the gap balancing technique suggests a deviation from mechanical alignment of more than 2 degrees of valgus or 4 degrees of varus, the suggestion is overruled by the mechanical alignment (maximum 2 degrees valgus, less than 4 degrees varus). Sample size calculations: To detect a clinically important difference of 0.17 in the rate of "high responders" and "non-responders" (OMERACT-OARSI criteria) to the Navio, with a standard deviation of 20, power 80% and a 0.05 significance level, a total of 194 patients must be included in the trial (97 patients in each group). The calculations are based on data from a previous study, by Petursson et al, JBJS Am 2018. When 10% eventual drop-outs are taken into account, the total number of patients to be included is 214 (107 patients in each group). A large number of patients is important, as the expected difference between the groups is small. A small difference may be less clinically relevant, however, may contribute to an overall better outcome for the patients in total. A small improvement of the tools combined with other small improvements may add up to be clinically important in the end. Small trials with no significant differences may disqualify important small improvements, thus stopping any further development in the field. Consequently, large clinical trials will be valuable. A radiostereometric analysis constitutes a separate study of the trial. A clinically relevant difference of 0.1 mm between the groups will be detected with a standard deviation of 0.1, power 80% and significance level 0.05, if 17 patients are included in each group. Including eventual drop-outs and an expectation of some failures due to the technically challenging investigation method (the RSA), a total of 30 patients will be included in each group. RSA radiographs will be collected within the first week after the operation, at 3 months, 1 year, 2 years and 5 years follow-ups. The trial is approved by the regional ethics committee and the data inspectorate of Norway.

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Arthritis, Degenerative, Osteo Arthritis Knee

7. Study Design

Primary Purpose
Treatment
Study Phase
Not Applicable
Interventional Study Model
Parallel Assignment
Model Description
Randomized, blinded (patient and outcomes assessor), clinical and radiostereometric trial
Masking
ParticipantInvestigatorOutcomes Assessor
Masking Description
Participants are blinded as the Navio system will be switched on at all operations, the outcomes assessors, statisticians and co-researchers will not get access to the randomization information.
Allocation
Randomized
Enrollment
214 (Anticipated)

8. Arms, Groups, and Interventions

Arm Title
Navio
Arm Type
Experimental
Arm Description
Using the new technology during surgery
Arm Title
Conventional
Arm Type
Active Comparator
Arm Description
Using the conventional surgical instruments
Intervention Type
Procedure
Intervention Name(s)
Navio
Intervention Description
New generation computer navigation with haptics and robotics
Intervention Type
Procedure
Intervention Name(s)
Conventional
Intervention Description
Total knee arthroplasty using conventional instruments
Primary Outcome Measure Information:
Title
Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) high responders
Description
Difference in rate (0.00-1.00) of high responders (calculated from KOOS)
Time Frame
3 months
Title
WOMAC high responders
Description
Difference in rate (0.00-1.00) of high responders (calculated from KOOS)
Time Frame
1 year
Title
WOMAC high responders
Description
Difference in rate (0.00-1.00) of high responders (calculated from KOOS)
Time Frame
2 years
Title
WOMAC high responders
Description
Difference in rate (0.00-1.00) of high responders (calculated from KOOS)
Time Frame
5 years
Title
Radiostereometric migration
Description
Maximum total point of motion MTPM (millimeters), (includes only first 60 patients)
Time Frame
1 year
Title
Radiostereometric migration
Description
Maximum total point of motion MTPM (millimeters), (includes only first 60 patients)
Time Frame
2 years
Title
Radiostereometric migration
Description
Maximum total point of motion MTPM (millimeters), (includes only first 60 patients)
Time Frame
5 years
Secondary Outcome Measure Information:
Title
Knee injury and osteoarthritis outcome score (KOOS)
Description
Symptoms, Stiffness, Pain, Activity of daily living, Sports, Quality of life subscores (0(worse)-100(better))
Time Frame
3 months
Title
Knee injury and osteoarthritis outcome score (KOOS)
Description
Symptoms, Stiffness, Pain, Activity of daily living, Sports, Quality of life subscores (0-100)
Time Frame
1 year
Title
Knee injury and osteoarthritis outcome score (KOOS)
Description
Symptoms, Stiffness, Pain, Activity of daily living, Sports, Quality of life subscores (0-100)
Time Frame
2 years
Title
Knee injury and osteoarthritis outcome score (KOOS)
Description
Symptoms, Stiffness, Pain, Activity of daily living, Sports, Quality of life subscores (0-100)
Time Frame
5 years
Title
Knee society score (KSS)
Description
Knee society score, knee score (0(worse)-100(better)) and function score (0(worse)-100(better))
Time Frame
3 months
Title
Knee society score (KSS)
Description
Knee society score, knee score (0-100) and function score (0-100)
Time Frame
1 year
Title
Knee society score (KSS)
Description
Knee society score, knee score (0-100) and function score (0-100)
Time Frame
2 years
Title
Knee society score (KSS)
Description
Knee society score, knee score (0-100) and function score (0-100)
Time Frame
5 years
Title
EQ-5D
Description
Euroqol, quality of life (0(worse)-100(better))
Time Frame
3 months
Title
EQ-5D
Description
Euroqol, quality of life (0-100)
Time Frame
1 year
Title
EQ-5D
Description
Euroqol, quality of life (0-100)
Time Frame
2 years
Title
EQ-5D
Description
Euroqol, quality of life (0-100)
Time Frame
5 years
Title
Visual analogue scale (VAS)
Description
Visual Analogue Scale pain (0(worse)-100(better))
Time Frame
pre-op, 3 months, 1 year, 2 years, 5 years
Title
Forgotten Joint Score (FJS)
Description
Forgotten Joint Score (0(worse)-100(better))
Time Frame
3 months
Title
Forgotten Joint Score (FJS)
Description
Forgotten Joint Score (0-100)
Time Frame
1 year
Title
Forgotten Joint Score (FJS)
Description
Forgotten Joint Score (0-100)
Time Frame
2 years
Title
Forgotten Joint Score (FJS)
Description
Forgotten Joint Score (0-100)
Time Frame
5 years
Title
Maximum climb-up test
Description
Height (cm) of one stair climbed with affected/operated limb (no pulling by hands)
Time Frame
3 months
Title
Maximum climb-up test
Description
Height (cm) of one stair climbed with affected/operated limb (no pulling by hands)
Time Frame
1 year
Title
Anchor questions
Description
Are you satisfied with the outcome? Would you do it again?
Time Frame
2 years
Title
Anchor questions
Description
Are you satisfied with the outcome? Would you do it again?
Time Frame
5 years
Title
Timed 40 meters walking test
Description
Time spent walking 40 meters
Time Frame
3 months
Title
Timed 40 meters walking test
Description
Time spent (in seconds) walking 40 meters
Time Frame
1 year
Title
Chair test 30 seconds
Description
number of repetitions from sitting to standing position during 30 seconds
Time Frame
3 months
Title
Chair test 30 seconds
Description
number of repetitions from sitting to standing position during 30 seconds
Time Frame
1 year
Other Pre-specified Outcome Measures:
Title
Position of the implant on radiographs, coronal and sagittal plane
Description
Femoral/tibial components: varus/valgus and flexion/extension, off-set of the femoral component
Time Frame
3 months

10. Eligibility

Sex
All
Minimum Age & Unit of Time
45 Years
Maximum Age & Unit of Time
85 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria: Degenerative knee in need of a total knee arthroplasty Recruited from the hospital's waiting list Informed consent Exclusion Criteria: Severe systemic illness Infections Severe neurological dysfunction Severe cancer disease Severe incompensated heart failure Severe incompensated lung disease Dementia Previous fracture or deformity of the limb, making the use of an intramedullary rod impossible (same side hip or ankle implant is not to be excluded if the rod unaffectedly reaches more than the first half of the femoral canal)
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Ove Furnes, MD/PhD
Organizational Affiliation
University of Bergen
Official's Role
Study Chair
Facility Information:
Facility Name
Haukeland university hospital
City
Bergen
ZIP/Postal Code
5021
Country
Norway
Facility Name
Haugesund sanitetsforenings revmatismesykehus
City
Haugesund
ZIP/Postal Code
5504
Country
Norway

12. IPD Sharing Statement

Plan to Share IPD
No
Citations:
PubMed Identifier
30066017
Citation
Batailler C, White N, Ranaldi FM, Neyret P, Servien E, Lustig S. Improved implant position and lower revision rate with robotic-assisted unicompartmental knee arthroplasty. Knee Surg Sports Traumatol Arthrosc. 2019 Apr;27(4):1232-1240. doi: 10.1007/s00167-018-5081-5. Epub 2018 Jul 31.
Results Reference
background
PubMed Identifier
30063588
Citation
Petursson G, Fenstad AM, Gothesen O, Dyrhovden GS, Hallan G, Rohrl SM, Aamodt A, Furnes O. Computer-Assisted Compared with Conventional Total Knee Replacement: A Multicenter Parallel-Group Randomized Controlled Trial. J Bone Joint Surg Am. 2018 Aug 1;100(15):1265-1274. doi: 10.2106/JBJS.17.01338.
Results Reference
background
PubMed Identifier
31256672
Citation
Robinson PG, Clement ND, Hamilton D, Blyth MJG, Haddad FS, Patton JT. A systematic review of robotic-assisted unicompartmental knee arthroplasty: prosthesis design and type should be reported. Bone Joint J. 2019 Jul;101-B(7):838-847. doi: 10.1302/0301-620X.101B7.BJJ-2018-1317.R1.
Results Reference
background
PubMed Identifier
31950265
Citation
Bollars P, Boeckxstaens A, Mievis J, Kalaai S, Schotanus MGM, Janssen D. Preliminary experience with an image-free handheld robot for total knee arthroplasty: 77 cases compared with a matched control group. Eur J Orthop Surg Traumatol. 2020 May;30(4):723-729. doi: 10.1007/s00590-020-02624-3. Epub 2020 Jan 16.
Results Reference
background
PubMed Identifier
9699158
Citation
Roos EM, Roos HP, Lohmander LS, Ekdahl C, Beynnon BD. Knee Injury and Osteoarthritis Outcome Score (KOOS)--development of a self-administered outcome measure. J Orthop Sports Phys Ther. 1998 Aug;28(2):88-96. doi: 10.2519/jospt.1998.28.2.88.
Results Reference
background
PubMed Identifier
9863983
Citation
Roos EM, Roos HP, Ekdahl C, Lohmander LS. Knee injury and Osteoarthritis Outcome Score (KOOS)--validation of a Swedish version. Scand J Med Sci Sports. 1998 Dec;8(6):439-48. doi: 10.1111/j.1600-0838.1998.tb00465.x.
Results Reference
background
PubMed Identifier
31711349
Citation
Heijbel S, Naili JE, Hedin A, W-Dahl A, Nilsson KG, Hedstrom M. The Forgotten Joint Score-12 in Swedish patients undergoing knee arthroplasty: a validation study with the Knee Injury and Osteoarthritis Outcome Score (KOOS) as comparator. Acta Orthop. 2020 Feb;91(1):88-93. doi: 10.1080/17453674.2019.1689327. Epub 2019 Nov 12.
Results Reference
background
PubMed Identifier
23617377
Citation
Ko V, Naylor JM, Harris IA, Crosbie J, Yeo AE. The six-minute walk test is an excellent predictor of functional ambulation after total knee arthroplasty. BMC Musculoskelet Disord. 2013 Apr 24;14:145. doi: 10.1186/1471-2474-14-145.
Results Reference
background
PubMed Identifier
26327798
Citation
Unver B, Kalkan S, Yuksel E, Kahraman T, Karatosun V. Reliability of the 50-foot walk test and 30-sec chair stand test in total knee arthroplasty. Acta Ortop Bras. 2015 Jul-Aug;23(4):184-7. doi: 10.1590/1413-78522015230401018.
Results Reference
background
PubMed Identifier
23966416
Citation
Nyberg LA, Hellenius ML, Wandell P, Kowalski J, Sundberg CJ. Maximal step-up height as a simple and relevant health indicator: a study of leg muscle strength and the associations to age, anthropometric variables, aerobic fitness and physical function. Br J Sports Med. 2013 Oct;47(15):992-7. doi: 10.1136/bjsports-2013-092577. Epub 2013 Aug 21.
Results Reference
background
PubMed Identifier
24788494
Citation
Gothesen O, Espehaug B, Havelin LI, Petursson G, Hallan G, Strom E, Dyrhovden G, Furnes O. Functional outcome and alignment in computer-assisted and conventionally operated total knee replacements: a multicentre parallel-group randomised controlled trial. Bone Joint J. 2014 May;96-B(5):609-18. doi: 10.1302/0301-620X.96B5.32516.
Results Reference
background
PubMed Identifier
29514366
Citation
Inui H, Taketomi S, Yamagami R, Shirakawa N, Kawaguchi K, Tanaka S. The Relationship between Soft-Tissue Balance and Intraoperative Kinematics of Guided Motion Total Knee Arthroplasty. J Knee Surg. 2019 Jan;32(1):91-96. doi: 10.1055/s-0038-1636545. Epub 2018 Mar 7.
Results Reference
background
PubMed Identifier
31488934
Citation
Iriuchishima T, Ryu K. Bicruciate Substituting Total Knee Arthroplasty Improves Stair Climbing Ability When Compared with Cruciate-Retain or Posterior Stabilizing Total Knee Arthroplasty. Indian J Orthop. 2019 Sep-Oct;53(5):641-645. doi: 10.4103/ortho.IJOrtho_392_18.
Results Reference
background
PubMed Identifier
31031156
Citation
Harris AI, Christen B, Malcorps JJ, O'Grady CP, Kopjar B, Sensiba PR, Vandenneucker H, Huang BK, Cates HE, Hur J, Marra DA. Midterm Performance of a Guided-Motion Bicruciate-Stabilized Total Knee System: Results From the International Study of Over 2000 Consecutive Primary Total Knee Arthroplasties. J Arthroplasty. 2019 Jul;34(7S):S201-S208. doi: 10.1016/j.arth.2019.02.011. Epub 2019 Feb 14.
Results Reference
background
PubMed Identifier
30972466
Citation
Kono K, Inui H, Tomita T, Yamazaki T, Taketomi S, Sugamoto K, Tanaka S. Bicruciate-stabilised total knee arthroplasty provides good functional stability during high-flexion weight-bearing activities. Knee Surg Sports Traumatol Arthrosc. 2019 Jul;27(7):2096-2103. doi: 10.1007/s00167-019-05375-9. Epub 2019 Apr 10.
Results Reference
background
PubMed Identifier
31821293
Citation
Di Benedetto P, Buttironi MM, Magnanelli S, Cainero V, Causero A. Comparison between standard technique and image-free robotic technique in medial unicompartmental knee arthroplasty. Preliminary data. Acta Biomed. 2019 Dec 5;90(12-S):104-108. doi: 10.23750/abm.v90i12-S.8994.
Results Reference
background
PubMed Identifier
23934905
Citation
Unver B, Kahraman T, Kalkan S, Yuksel E, Karatosun V. Reliability of the six-minute walk test after total hip arthroplasty. Hip Int. 2013 Nov-Dec;23(6):541-5. doi: 10.5301/hipint.5000073. Epub 2013 Aug 6.
Results Reference
background
PubMed Identifier
27996349
Citation
Petursson G, Fenstad AM, Gothesen O, Haugan K, Dyrhovden GS, Hallan G, Rohrl SM, Aamodt A, Nilsson KG, Furnes O. Similar migration in computer-assisted and conventional total knee arthroplasty. Acta Orthop. 2017 Apr;88(2):166-172. doi: 10.1080/17453674.2016.1267835. Epub 2016 Dec 20.
Results Reference
background

Learn more about this trial

Robotized Navigation Compared to Conventional Technique in Total Knee Replacement

We'll reach out to this number within 24 hrs