search
Back to results

Safety and Effectiveness of the Orsiro Sirolimus Eluting Coronary Stent System in Subjects With Coronary Artery Lesions (BIOFLOW-V)

Primary Purpose

Coronary Artery Disease, Atherosclerosis, Coronary, Myocardial Ischemia

Status
Completed
Phase
Not Applicable
Locations
International
Study Type
Interventional
Intervention
Orsiro DES
Xience DES
Sponsored by
Biotronik, Inc.
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional treatment trial for Coronary Artery Disease focused on measuring Drug eluting coronary stents, Sirolimus, Bioabsorbable polymer, DES

Eligibility Criteria

18 Years - undefined (Adult, Older Adult)All SexesDoes not accept healthy volunteers

Inclusion Criteria:

  1. Subject is ≥18 years or the minimum age required for legal adult consent in the country of enrollment.
  2. Subject is an acceptable candidate for PCI.
  3. Subject is an acceptable candidate for CABG.
  4. Subject has clinical evidence of ischemic heart disease, stable or unstable angina pectoris or documented silent ischemia.
  5. Subject is eligible for dual anti-platelet therapy treatment with aspirin plus either, clopidogrel, prasugrel, ticagrelor or ticlopidine.
  6. Subject has provided written informed consent.
  7. Subject is willing to comply with study follow-up requirements.

Each target lesion/vessel must meet all of the following angiographic criteria for the subject to be eligible for the trial:

  1. Subject has up to three target lesions in up to two separate target vessels (two target lesions in one vessel and one target lesion in a separate vessel).
  2. Target lesion must be de novo or restenotic lesion in native coronary artery; restenotic lesion must have been treated with a standard PTCA only.
  3. Target lesion must be in major coronary artery or branch (target vessel).
  4. Target lesion must have angiographic evidence of ≥ 50% and < 100% stenosis (by operator visual estimate). If the target lesion is < 70% stenosed, clinical evidence of ischemia by positive functional study, CT, electrocardiography, FFR, or post infarct angina.
  5. TIMI flow > 1.
  6. Target lesion must be ≤ 36 mm in length by operator visual estimate.
  7. Target vessel RVD of 2.25-4.0 mm by operator visual estimate.
  8. Target lesion must be treatable with a maximum of two overlapping stents.

Exclusion Criteria:

  1. Subject has clinical symptoms and/or electrocardiogram (ECG) changes consistent with acute ST elevation myocardial infarction (STEMI) within 72 hours prior to the index procedure. Hemodynamically stable non-STEMI (NSTEMI) subjects are eligible for study enrollment.
  2. Subject is hemodynamically unstable.
  3. Subject is pregnant and/or breastfeeding or intends to become pregnant during the duration of the study.
  4. Subject has a known allergy to contrast medium that cannot be adequately pre-medicated, or any known allergy to thienopyridine, aspirin, both heparin and bivalirudin, L-605 cobalt-chromium (Co-Cr) alloy or one of its major elements (cobalt, chromium, tungsten and nickel), acrylic, fluoropolymers, silicon carbide, PLLA, sirolimus or everolimus.
  5. Revascularization of any target vessel within 9 months prior to the index procedure or previous PCI of any non-target vessel within 30 days prior to the index procedure.
  6. Planned treatment of a lesion not meeting angiographic inclusion and exclusion criteria during the index procedure or after the index procedure.
  7. Planned surgery within 6 months of index procedure unless dual antiplatelet therapy can be maintained throughout the peri-surgical period.
  8. History of a stroke or transient ischemic attack (TIA) within 6 months prior to the index procedure.
  9. Subjects with active bleeding disorders, active coagulopathy, or any other reason, who are ineligible for DAPT.
  10. Subject will refuse blood transfusions.
  11. Subject has documented left ventricular ejection fraction (LVEF) < 30% within 90 days prior to the index procedure.
  12. Subject is dialysis-dependent.
  13. Subject has impaired renal function (i.e., blood creatinine > 2.5 mg/dL or 221 μmol/L determined within 7 days prior to the index procedure).
  14. Subject has leukopenia (i.e. < 3,000 white blood cells/mm3), thrombocytopenia (i.e. < 100,000 platelets/mm3) or thrombocytosis (i.e. > 700,000 platelet/mm3).
  15. Subject is receiving oral or intravenous immunosuppressive therapy (inhaled steroids are permitted), or has known life-limiting immunosuppressive or autoimmune disease (e.g., human immunodeficiency virus, systemic lupus erythematosus; diabetes mellitus is permitted).
  16. Subject is receiving chronic anticoagulation (e.g. coumadin, dabigatran, apixaban, rivaroxaban or any other agent).
  17. Subject has life expectancy of < 1 year.
  18. Subject is participating in another investigational (medical device or drug) clinical study. Subjects may be concurrently enrolled in a post-market study, as long as the post-market study device, drug or protocol does not interfere with the investigational treatment or protocol of this study.
  19. In the investigator's opinion, subject will not be able to comply with the follow-up requirements.

Subjects will be excluded from the trial if any of the target lesions/vessels meets any of the following angiographic criteria:

  1. Target lesion is located within a saphenous vein graft or arterial graft.
  2. Target lesion is a restenotic lesion that was previously treated with a bare metal or drug eluting stent (in-stent restenosis).
  3. Target lesion has any of the following characteristics:

    1. Lesion location is within the left main coronary artery, or within 3 mm of the origin of the left anterior descending (LAD) or left circumflex (LCX).
    2. Involves a side branch of > 2.0 mm in diameter. Note: Lesions within 3 mm of the origin of the right coronary artery may be treated.
  4. Target vessel/lesion is excessively tortuous/angulated or is severely calcified, that would prevent complete inflation of an angioplasty balloon. This assessment should be based on visual estimation.
  5. Target vessel has angiographic evidence of thrombus.
  6. Target lesion is totally occluded (100% stenosis).
  7. Target vessel was treated with brachytherapy any time prior to the index procedure.

Sites / Locations

Arms of the Study

Arm 1

Arm 2

Arm Type

Experimental

Active Comparator

Arm Label

Orsiro sirolimus coronary stent system

Xience everolimus coronary stent system

Arm Description

Intervention with a Orsiro DES.

Intervention with a Xience DES.

Outcomes

Primary Outcome Measures

Percentage of Participants With Target Lesion Failure (TLF) at 12 Months Post-Index Procedure by Bayesian Estimation
TLF is defined as all cardiac death, target vessel Q-wave or non-Q-wave myocardial infarction (MI), or clinically driven target lesion revascularization (TLR).

Secondary Outcome Measures

Number of Lesions With Device Success
Defined as attainment of < 30% residual stenosis of the target lesion using the assigned study stent only.
Number of Lesions With Lesion Success
Defined as attainment of < 30% residual stenosis of the target lesion using any percutaneous method.
Number of Participants With Procedure Success
Defined as attainment of < 30% residual stenosis of the target lesion using the assigned study stent only without occurrence of in-hospital major adverse cardiac events (MACE; composite of all-cause death, Q-wave or non-Q-wave MI, and any clinically-driven TLR).
Number of Participants With Myocardial Infarction
Number of Participants With Myocardial Infarction or Cardiac Death
Number of Participants With MACE and Individual MACE Components
MACE events are defined as all-cause death, Q-wave or non-Q-wave MI, or any clinically-driven TLR. The number of participants with any MACE event is provided, as well as number of participants with each of the individual components.
Number of Participants With TLF and Individual TLF Components
TLF events are defined as cardiac death, target vessel Q-wave or non-Q-wave MI, or any clinically-driven TLR. The number of participants with any TLF event is provided, as well as number of participants with each of the individual components.
Number of Participants With Target Vessel Failure (TVF) and Individual TVF Components
TVF events are defined as cardiac death, target vessel Q-wave or non-Q-wave MI, or any clinically-driven TVR. The number of participants with any TVF event is provided, as well as number of participants with each of the individual components.
Number of Participants With Stent Thrombosis
Stent thrombosis according to the Academic Research Consortium criteria.

Full Information

First Posted
March 2, 2015
Last Updated
August 1, 2022
Sponsor
Biotronik, Inc.
Collaborators
Biotronik AG, Baim Institute for Clinical Research, Medstar Health Research Institute
search

1. Study Identification

Unique Protocol Identification Number
NCT02389946
Brief Title
Safety and Effectiveness of the Orsiro Sirolimus Eluting Coronary Stent System in Subjects With Coronary Artery Lesions
Acronym
BIOFLOW-V
Official Title
BIOTRONIK - A Prospective Randomized Multicenter Study to Assess the SaFety and Effectiveness of the Orsiro SiroLimus Eluting Coronary Stent System in the Treatment Of Subjects With up to Three De Novo or Restenotic Coronary Artery Lesions - V
Study Type
Interventional

2. Study Status

Record Verification Date
August 2022
Overall Recruitment Status
Completed
Study Start Date
May 2015 (undefined)
Primary Completion Date
April 2017 (Actual)
Study Completion Date
March 2021 (Actual)

3. Sponsor/Collaborators

Responsible Party, by Official Title
Sponsor
Name of the Sponsor
Biotronik, Inc.
Collaborators
Biotronik AG, Baim Institute for Clinical Research, Medstar Health Research Institute

4. Oversight

Data Monitoring Committee
Yes

5. Study Description

Brief Summary
The objective of this study is to assess the safety and efficacy of the Orsiro Sirolimus Eluting Coronary Stent System in the treatment of subjects with up to three native de novo or restenotic (standard PTCA only) coronary artery lesions compared to the Xience coronary stent system.
Detailed Description
The BIOTRONIK BIOFLOW-V clinical trial is a prospective, multicenter, randomized, controlled trial combining data on the randomized subjects with data from two historical studies by employing a Bayesian approach. Subjects with CAD that qualify for PCI with stenting will be screened per the protocol inclusion and exclusion criteria to achieve a total of up to 1,400 randomized subjects. Eligible subjects will be randomized in a 2:1 ratio, stratified by study center, to undergo percutaneous coronary revascularization with either the Orsiro Sirolimus Eluting Stent System (treatment group) or the Xience Everolimus Eluting Stent System (control group). Subjects may receive treatment of up to three target lesions, one or two target lesions per target vessel, for a maximum of two target vessels. The target lesion(s) must be de novo or restenotic lesion(s) of ≤ 36 mm in length in native coronary artery(ies), with a reference vessel diameter of 2.25-4.0 mm. Treatment of restenotic lesions is allowed provided that the target lesion was previously treated with PTCA only. All treatment with study stents is to be performed during a single index procedure. Note: Concurrent treatment of non-target lesions during the index procedure is not allowed. Randomized subjects will have clinical follow-up at 1 month, 6 months, 12 months and at 2, 3, 4 and 5 years following the index procedure. To assess the non-inferiority of the Orsiro stent compared to the Xience stent, BIOFLOW-V randomized subjects will be combined with historical subjects from the BIOFLOW-II and BIOFLOW-IV randomized trials employing a Bayesian approach. Only subjects who meet all clinical and angiographic eligibility criteria of the BIOFLOW-V trial will be included in the analysis.

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Coronary Artery Disease, Atherosclerosis, Coronary, Myocardial Ischemia, Ischemic Heart Disease, Acute Coronary Syndrome, Angina Pectoris
Keywords
Drug eluting coronary stents, Sirolimus, Bioabsorbable polymer, DES

7. Study Design

Primary Purpose
Treatment
Study Phase
Not Applicable
Interventional Study Model
Parallel Assignment
Masking
Outcomes Assessor
Allocation
Randomized
Enrollment
1334 (Actual)

8. Arms, Groups, and Interventions

Arm Title
Orsiro sirolimus coronary stent system
Arm Type
Experimental
Arm Description
Intervention with a Orsiro DES.
Arm Title
Xience everolimus coronary stent system
Arm Type
Active Comparator
Arm Description
Intervention with a Xience DES.
Intervention Type
Device
Intervention Name(s)
Orsiro DES
Other Intervention Name(s)
Orsiro sirolimus coronary stent system
Intervention Description
Orsiro is a device/drug combination product composed of two components, a device (coronary stent system including a cobalt chromium stent platform), and a drug product (a formulation of sirolimus) contained in a bioabsorbable polymer coating.
Intervention Type
Device
Intervention Name(s)
Xience DES
Other Intervention Name(s)
Xience everolimus coronary stent system
Primary Outcome Measure Information:
Title
Percentage of Participants With Target Lesion Failure (TLF) at 12 Months Post-Index Procedure by Bayesian Estimation
Description
TLF is defined as all cardiac death, target vessel Q-wave or non-Q-wave myocardial infarction (MI), or clinically driven target lesion revascularization (TLR).
Time Frame
12-Months
Secondary Outcome Measure Information:
Title
Number of Lesions With Device Success
Description
Defined as attainment of < 30% residual stenosis of the target lesion using the assigned study stent only.
Time Frame
Hospital Discharge (6-24 hours post-index procedure)
Title
Number of Lesions With Lesion Success
Description
Defined as attainment of < 30% residual stenosis of the target lesion using any percutaneous method.
Time Frame
Hospital Discharge (6-24 hours post-index procedure)
Title
Number of Participants With Procedure Success
Description
Defined as attainment of < 30% residual stenosis of the target lesion using the assigned study stent only without occurrence of in-hospital major adverse cardiac events (MACE; composite of all-cause death, Q-wave or non-Q-wave MI, and any clinically-driven TLR).
Time Frame
Hospital Discharge (6-24 hours post-index procedure)
Title
Number of Participants With Myocardial Infarction
Time Frame
Hospital Discharge (6-24 hours post-index procedure), 1, 6, 12 months, 2, 3, 4 and 5 years
Title
Number of Participants With Myocardial Infarction or Cardiac Death
Time Frame
Hospital Discharge (6-24 hours post-index procedure), 1, 6, 12 months, 2, 3, 4 and 5 years
Title
Number of Participants With MACE and Individual MACE Components
Description
MACE events are defined as all-cause death, Q-wave or non-Q-wave MI, or any clinically-driven TLR. The number of participants with any MACE event is provided, as well as number of participants with each of the individual components.
Time Frame
Hospital Discharge (6-24 hours post-index procedure), 1, 6, 12 months, 2, 3, 4 and 5 years
Title
Number of Participants With TLF and Individual TLF Components
Description
TLF events are defined as cardiac death, target vessel Q-wave or non-Q-wave MI, or any clinically-driven TLR. The number of participants with any TLF event is provided, as well as number of participants with each of the individual components.
Time Frame
Hospital Discharge (6-24 hours post-index procedure), 1, 6, 12 months, 2, 3, 4 and 5 years
Title
Number of Participants With Target Vessel Failure (TVF) and Individual TVF Components
Description
TVF events are defined as cardiac death, target vessel Q-wave or non-Q-wave MI, or any clinically-driven TVR. The number of participants with any TVF event is provided, as well as number of participants with each of the individual components.
Time Frame
Hospital Discharge (6-24 hours post-index procedure), 1, 6, 12 months, 2, 3, 4 and 5 years
Title
Number of Participants With Stent Thrombosis
Description
Stent thrombosis according to the Academic Research Consortium criteria.
Time Frame
24 hours, 30 days, 1 year, and 5 years post-index procedure

10. Eligibility

Sex
All
Minimum Age & Unit of Time
18 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria: Subject is ≥18 years or the minimum age required for legal adult consent in the country of enrollment. Subject is an acceptable candidate for PCI. Subject is an acceptable candidate for CABG. Subject has clinical evidence of ischemic heart disease, stable or unstable angina pectoris or documented silent ischemia. Subject is eligible for dual anti-platelet therapy treatment with aspirin plus either, clopidogrel, prasugrel, ticagrelor or ticlopidine. Subject has provided written informed consent. Subject is willing to comply with study follow-up requirements. Each target lesion/vessel must meet all of the following angiographic criteria for the subject to be eligible for the trial: Subject has up to three target lesions in up to two separate target vessels (two target lesions in one vessel and one target lesion in a separate vessel). Target lesion must be de novo or restenotic lesion in native coronary artery; restenotic lesion must have been treated with a standard PTCA only. Target lesion must be in major coronary artery or branch (target vessel). Target lesion must have angiographic evidence of ≥ 50% and < 100% stenosis (by operator visual estimate). If the target lesion is < 70% stenosed, clinical evidence of ischemia by positive functional study, CT, electrocardiography, FFR, or post infarct angina. TIMI flow > 1. Target lesion must be ≤ 36 mm in length by operator visual estimate. Target vessel RVD of 2.25-4.0 mm by operator visual estimate. Target lesion must be treatable with a maximum of two overlapping stents. Exclusion Criteria: Subject has clinical symptoms and/or electrocardiogram (ECG) changes consistent with acute ST elevation myocardial infarction (STEMI) within 72 hours prior to the index procedure. Hemodynamically stable non-STEMI (NSTEMI) subjects are eligible for study enrollment. Subject is hemodynamically unstable. Subject is pregnant and/or breastfeeding or intends to become pregnant during the duration of the study. Subject has a known allergy to contrast medium that cannot be adequately pre-medicated, or any known allergy to thienopyridine, aspirin, both heparin and bivalirudin, L-605 cobalt-chromium (Co-Cr) alloy or one of its major elements (cobalt, chromium, tungsten and nickel), acrylic, fluoropolymers, silicon carbide, PLLA, sirolimus or everolimus. Revascularization of any target vessel within 9 months prior to the index procedure or previous PCI of any non-target vessel within 30 days prior to the index procedure. Planned treatment of a lesion not meeting angiographic inclusion and exclusion criteria during the index procedure or after the index procedure. Planned surgery within 6 months of index procedure unless dual antiplatelet therapy can be maintained throughout the peri-surgical period. History of a stroke or transient ischemic attack (TIA) within 6 months prior to the index procedure. Subjects with active bleeding disorders, active coagulopathy, or any other reason, who are ineligible for DAPT. Subject will refuse blood transfusions. Subject has documented left ventricular ejection fraction (LVEF) < 30% within 90 days prior to the index procedure. Subject is dialysis-dependent. Subject has impaired renal function (i.e., blood creatinine > 2.5 mg/dL or 221 μmol/L determined within 7 days prior to the index procedure). Subject has leukopenia (i.e. < 3,000 white blood cells/mm3), thrombocytopenia (i.e. < 100,000 platelets/mm3) or thrombocytosis (i.e. > 700,000 platelet/mm3). Subject is receiving oral or intravenous immunosuppressive therapy (inhaled steroids are permitted), or has known life-limiting immunosuppressive or autoimmune disease (e.g., human immunodeficiency virus, systemic lupus erythematosus; diabetes mellitus is permitted). Subject is receiving chronic anticoagulation (e.g. coumadin, dabigatran, apixaban, rivaroxaban or any other agent). Subject has life expectancy of < 1 year. Subject is participating in another investigational (medical device or drug) clinical study. Subjects may be concurrently enrolled in a post-market study, as long as the post-market study device, drug or protocol does not interfere with the investigational treatment or protocol of this study. In the investigator's opinion, subject will not be able to comply with the follow-up requirements. Subjects will be excluded from the trial if any of the target lesions/vessels meets any of the following angiographic criteria: Target lesion is located within a saphenous vein graft or arterial graft. Target lesion is a restenotic lesion that was previously treated with a bare metal or drug eluting stent (in-stent restenosis). Target lesion has any of the following characteristics: Lesion location is within the left main coronary artery, or within 3 mm of the origin of the left anterior descending (LAD) or left circumflex (LCX). Involves a side branch of > 2.0 mm in diameter. Note: Lesions within 3 mm of the origin of the right coronary artery may be treated. Target vessel/lesion is excessively tortuous/angulated or is severely calcified, that would prevent complete inflation of an angioplasty balloon. This assessment should be based on visual estimation. Target vessel has angiographic evidence of thrombus. Target lesion is totally occluded (100% stenosis). Target vessel was treated with brachytherapy any time prior to the index procedure.
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Ron Waksman, MD
Organizational Affiliation
Medstar Washington Hospital Center
Official's Role
Study Chair
First Name & Middle Initial & Last Name & Degree
David Kandzari, MD
Organizational Affiliation
Piedmont Heart Institute
Official's Role
Principal Investigator
First Name & Middle Initial & Last Name & Degree
Jacques Koolen, MD
Organizational Affiliation
Catharina Ziekenhuis
Official's Role
Principal Investigator
Facility Information:
City
Fairhope
State/Province
Alabama
ZIP/Postal Code
36535
Country
United States
City
Concord
State/Province
California
ZIP/Postal Code
94520
Country
United States
City
La Mesa
State/Province
California
ZIP/Postal Code
91942
Country
United States
City
Laguna Hills
State/Province
California
ZIP/Postal Code
92653
Country
United States
City
Mission Viejo
State/Province
California
ZIP/Postal Code
92691
Country
United States
City
Washington
State/Province
District of Columbia
ZIP/Postal Code
20010
Country
United States
City
Clearwater
State/Province
Florida
ZIP/Postal Code
33756
Country
United States
City
Hollywood
State/Province
Florida
ZIP/Postal Code
33021
Country
United States
City
Orlando
State/Province
Florida
ZIP/Postal Code
32803
Country
United States
City
Tampa
State/Province
Florida
ZIP/Postal Code
33613
Country
United States
City
Atlanta
State/Province
Georgia
ZIP/Postal Code
30309
Country
United States
City
Urbana
State/Province
Illinois
ZIP/Postal Code
61801
Country
United States
City
Fort Wayne
State/Province
Indiana
ZIP/Postal Code
46845
Country
United States
City
Baltimore
State/Province
Maryland
ZIP/Postal Code
21218
Country
United States
City
Boston
State/Province
Massachusetts
ZIP/Postal Code
02120
Country
United States
City
Bay City
State/Province
Michigan
ZIP/Postal Code
48708
Country
United States
City
Detroit
State/Province
Michigan
ZIP/Postal Code
48236
Country
United States
City
Lansing
State/Province
Michigan
ZIP/Postal Code
48912
Country
United States
City
Pontiac
State/Province
Michigan
ZIP/Postal Code
48341
Country
United States
City
Rochester
State/Province
Michigan
ZIP/Postal Code
48307
Country
United States
City
Troy
State/Province
Michigan
ZIP/Postal Code
48085
Country
United States
City
Ypsilanti
State/Province
Michigan
ZIP/Postal Code
48197
Country
United States
City
Minneapolis
State/Province
Minnesota
ZIP/Postal Code
55407
Country
United States
City
Omaha
State/Province
Nebraska
ZIP/Postal Code
68124
Country
United States
City
Hackensack
State/Province
New Jersey
ZIP/Postal Code
07601
Country
United States
City
Neptune
State/Province
New Jersey
ZIP/Postal Code
07753
Country
United States
City
Newark
State/Province
New Jersey
ZIP/Postal Code
07102
Country
United States
City
New York
State/Province
New York
ZIP/Postal Code
10021
Country
United States
City
New York
State/Province
New York
ZIP/Postal Code
10029
Country
United States
City
New York
State/Province
New York
ZIP/Postal Code
10032
Country
United States
City
Asheville
State/Province
North Carolina
ZIP/Postal Code
28803
Country
United States
City
Greensboro
State/Province
North Carolina
ZIP/Postal Code
27401
Country
United States
City
Fargo
State/Province
North Dakota
ZIP/Postal Code
58102
Country
United States
City
Cincinnati
State/Province
Ohio
ZIP/Postal Code
45219
Country
United States
City
Cleveland
State/Province
Ohio
ZIP/Postal Code
44111
Country
United States
City
Columbus
State/Province
Ohio
ZIP/Postal Code
43210
Country
United States
City
Elyria
State/Province
Ohio
ZIP/Postal Code
44035
Country
United States
City
Toledo
State/Province
Ohio
ZIP/Postal Code
43606
Country
United States
City
Toledo
State/Province
Ohio
ZIP/Postal Code
43608
Country
United States
City
Portland
State/Province
Oregon
ZIP/Postal Code
97225
Country
United States
City
Butler
State/Province
Pennsylvania
ZIP/Postal Code
16001
Country
United States
City
Mechanicsburg
State/Province
Pennsylvania
ZIP/Postal Code
17050
Country
United States
City
Wynnewood
State/Province
Pennsylvania
ZIP/Postal Code
19096
Country
United States
City
York
State/Province
Pennsylvania
ZIP/Postal Code
17403
Country
United States
City
Providence
State/Province
Rhode Island
ZIP/Postal Code
02906
Country
United States
City
Greenville
State/Province
South Carolina
ZIP/Postal Code
29605
Country
United States
City
Rock Hill
State/Province
South Carolina
ZIP/Postal Code
29732
Country
United States
City
Knoxville
State/Province
Tennessee
ZIP/Postal Code
37934
Country
United States
City
Dallas
State/Province
Texas
ZIP/Postal Code
75226
Country
United States
City
Houston
State/Province
Texas
ZIP/Postal Code
77030
Country
United States
City
McKinney
State/Province
Texas
ZIP/Postal Code
75069
Country
United States
City
Tyler
State/Province
Texas
ZIP/Postal Code
75701
Country
United States
City
Charlottesville
State/Province
Virginia
ZIP/Postal Code
22908
Country
United States
City
Virginia Beach
State/Province
Virginia
ZIP/Postal Code
23454
Country
United States
City
Charleston
State/Province
West Virginia
ZIP/Postal Code
25304
Country
United States
City
Adelaide
ZIP/Postal Code
SA 5011
Country
Australia
City
Genk
ZIP/Postal Code
3600
Country
Belgium
City
Leuven
ZIP/Postal Code
3000
Country
Belgium
City
Roeselare
ZIP/Postal Code
8800
Country
Belgium
City
Calgary
State/Province
Alberta
ZIP/Postal Code
T2N 4Z6
Country
Canada
City
Aarhus
ZIP/Postal Code
8200
Country
Denmark
City
Bad Segeberg
ZIP/Postal Code
23795
Country
Germany
City
Berlin
ZIP/Postal Code
10249
Country
Germany
City
Berlin
ZIP/Postal Code
10967
Country
Germany
City
Hamburg
ZIP/Postal Code
20246
Country
Germany
City
Minden
ZIP/Postal Code
32429
Country
Germany
City
Neuss
ZIP/Postal Code
41464
Country
Germany
City
Budapest
ZIP/Postal Code
1085
Country
Hungary
City
Pécs
ZIP/Postal Code
7624
Country
Hungary
City
Szeged
ZIP/Postal Code
6720
Country
Hungary
City
Haifa
ZIP/Postal Code
31096
Country
Israel
City
Jerusalem
ZIP/Postal Code
91120
Country
Israel
City
Petach Tikva
ZIP/Postal Code
49101
Country
Israel
City
Rehovot
ZIP/Postal Code
76100
Country
Israel
City
Tel Aviv
ZIP/Postal Code
64239
Country
Israel
City
Daegu
ZIP/Postal Code
705-718
Country
Korea, Republic of
City
Gwangju
ZIP/Postal Code
501-757
Country
Korea, Republic of
City
Seoul
ZIP/Postal Code
110-744
Country
Korea, Republic of
City
Seoul
ZIP/Postal Code
135-720
Country
Korea, Republic of
City
Seoul
ZIP/Postal Code
137-701
Country
Korea, Republic of
City
Breda
ZIP/Postal Code
4818 CK
Country
Netherlands
City
Eindhoven
ZIP/Postal Code
5623 EJ
Country
Netherlands
City
Nieuwegein
ZIP/Postal Code
3435 CM
Country
Netherlands
City
Auckland
ZIP/Postal Code
1142
Country
New Zealand
City
Barcelona
ZIP/Postal Code
08036
Country
Spain
City
Barcelona
ZIP/Postal Code
08907
Country
Spain
City
Madrid
ZIP/Postal Code
28222
Country
Spain
City
Malaga
ZIP/Postal Code
29010
Country
Spain
City
Sevilla
ZIP/Postal Code
41071
Country
Spain
City
Lausanne
ZIP/Postal Code
1011
Country
Switzerland
City
Zurich
ZIP/Postal Code
8063
Country
Switzerland
City
Zurich
ZIP/Postal Code
8091
Country
Switzerland

12. IPD Sharing Statement

Plan to Share IPD
Undecided
Citations:
PubMed Identifier
29129253
Citation
Doros G, Massaro JM, Kandzari DE, Waksman R, Koolen JJ, Cutlip DE, Mauri L. Rationale of a novel study design for the BIOFLOW V study, a prospective, randomized multicenter study to assess the safety and efficacy of the Orsiro sirolimus-eluting coronary stent system using a Bayesian approach. Am Heart J. 2017 Nov;193:35-45. doi: 10.1016/j.ahj.2017.08.001. Epub 2017 Aug 5.
Results Reference
background
PubMed Identifier
28851504
Citation
Kandzari DE, Mauri L, Koolen JJ, Massaro JM, Doros G, Garcia-Garcia HM, Bennett J, Roguin A, Gharib EG, Cutlip DE, Waksman R; BIOFLOW V Investigators. Ultrathin, bioresorbable polymer sirolimus-eluting stents versus thin, durable polymer everolimus-eluting stents in patients undergoing coronary revascularisation (BIOFLOW V): a randomised trial. Lancet. 2017 Oct 21;390(10105):1843-1852. doi: 10.1016/S0140-6736(17)32249-3. Epub 2017 Aug 26. Erratum In: Lancet. 2017 Oct 21;390(10105):1832.
Results Reference
result
PubMed Identifier
30257191
Citation
Kandzari DE, Koolen JJ, Doros G, Massaro JJ, Garcia-Garcia HM, Bennett J, Roguin A, Gharib EG, Cutlip DE, Waksman R; BIOFLOW V Investigators. Ultrathin Bioresorbable Polymer Sirolimus-Eluting Stents Versus Thin Durable Polymer Everolimus-Eluting Stents. J Am Coll Cardiol. 2018 Dec 25;72(25):3287-3297. doi: 10.1016/j.jacc.2018.09.019. Epub 2018 Sep 23.
Results Reference
result
PubMed Identifier
30354631
Citation
Roguin A, Kandzari DE, Marcusohn E, Koolen JJ, Doros G, Massaro JM, Garcia-Garcia HM, Bennett J, Gharib EG, Cutlip DE, Waksman R. Subgroup Analysis Comparing Ultrathin, Bioresorbable Polymer Sirolimus-Eluting Stents Versus Thin, Durable Polymer Everolimus-Eluting Stents in Acute Coronary Syndrome Patients. Circ Cardiovasc Interv. 2018 Oct;11(10):e007331. doi: 10.1161/CIRCINTERVENTIONS.118.007331.
Results Reference
result
PubMed Identifier
35212802
Citation
Hemetsberger R, Abdelghani M, Toelg R, Garcia-Garcia HM, Farhan S, Mankerious N, Elbasha K, Allali A, Windecker S, Lefevre T, Saito S, Kandzari D, Waksman R, Richardt G. Complex vs. non-complex percutaneous coronary intervention with newer-generation drug-eluting stents: an analysis from the randomized BIOFLOW trials. Clin Res Cardiol. 2022 Jul;111(7):795-805. doi: 10.1007/s00392-022-01994-4. Epub 2022 Feb 25.
Results Reference
derived
PubMed Identifier
34056911
Citation
Hemetsberger R, Abdelghani M, Toelg R, Mankerious N, Allali A, Garcia-Garcia HM, Windecker S, Lefevre T, Saito S, Slagboom T, Kandzari D, Koolen J, Waksman R, Richardt G. Impact of Coronary Calcification on Clinical Outcomes After Implantation of Newer-Generation Drug-Eluting Stents. J Am Heart Assoc. 2021 Jun 15;10(12):e019815. doi: 10.1161/JAHA.120.019815. Epub 2021 May 29.
Results Reference
derived
PubMed Identifier
32895004
Citation
Dan K, Garcia-Garcia HM, Kolm P, Windecker S, Saito S, Kandzari DE, Waksman R. Comparison of Ultrathin, Bioresorbable-Polymer Sirolimus-Eluting Stents and Thin, Durable-Polymer Everolimus-Eluting Stents in Calcified or Small Vessel Lesions. Circ Cardiovasc Interv. 2020 Sep;13(9):e009189. doi: 10.1161/CIRCINTERVENTIONS.120.009189. Epub 2020 Sep 8.
Results Reference
derived
PubMed Identifier
32890442
Citation
Toelg R, Slagboom T, Waltenberger J, Lefevre T, Saito S, Kandzari DE, Koolen J, Richardt G. Individual patient data analysis of the BIOFLOW study program comparing safety and efficacy of a bioresorbable polymer sirolimus eluting stent to a durable polymer everolimus eluting stent. Catheter Cardiovasc Interv. 2021 Nov 1;98(5):848-856. doi: 10.1002/ccd.29254. Epub 2020 Sep 5.
Results Reference
derived
PubMed Identifier
32499026
Citation
Kandzari DE, Koolen JJ, Doros G, Garcia-Garcia HM, Bennett J, Roguin A, Gharib EG, Cutlip DE, Waksman R; BIOFLOW V Investigators. Ultrathin Bioresorbable-Polymer Sirolimus-Eluting Stents Versus Thin Durable-Polymer Everolimus-Eluting Stents for Coronary Revascularization: 3-Year Outcomes From the Randomized BIOFLOW V Trial. JACC Cardiovasc Interv. 2020 Jun 8;13(11):1343-1353. doi: 10.1016/j.jcin.2020.02.019.
Results Reference
derived
PubMed Identifier
31954661
Citation
Mattke S, Hanson M, Bentele M, Kandzari DE. Cost and Mortality Implications of Lower Event Rates After Implantation of an Ultrathin-Strut Coronary Stent Compared With a Thin-Strut Stent Over Four Years. Cardiovasc Revasc Med. 2020 Jul;21(7):835-842. doi: 10.1016/j.carrev.2019.12.018. Epub 2019 Dec 18.
Results Reference
derived
PubMed Identifier
30638888
Citation
Mattke S, Hanson M, Dallmann AC, Bentele M. Health Economic Evaluation of an Ultrathin, Bioresorbable-Polymer Sirolimus-Eluting Coronary Stent Compared to a Thin, Durable-Polymer Everolimus-Eluting Stent. Cardiovasc Revasc Med. 2019 Sep;20(9):752-757. doi: 10.1016/j.carrev.2018.11.006. Epub 2018 Nov 20.
Results Reference
derived

Learn more about this trial

Safety and Effectiveness of the Orsiro Sirolimus Eluting Coronary Stent System in Subjects With Coronary Artery Lesions

We'll reach out to this number within 24 hrs