search
Back to results

Safety and Efficacy Continued Access Study of the Medtronic CoreValve® System in the Treatment of Symptomatic Severe Aortic Stenosis in Very High Risk Subjects and High Risk Subjects Who Need Aortic Valve Replacement

Primary Purpose

Severe Aortic Stenosis

Status
Completed
Phase
Not Applicable
Locations
United States
Study Type
Interventional
Intervention
Medtronic CoreValve® System Transcatheter Aortic Valve Implantation (TAVI)
Sponsored by
Medtronic Cardiovascular
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional treatment trial for Severe Aortic Stenosis focused on measuring Valvular Heart Disease, Critical Aortic Stenosis, Severe Aortic Stenosis, Extreme Risk, High Risk, Aortic Valve Replacement

Eligibility Criteria

undefined - undefined (Child, Adult, Older Adult)All SexesDoes not accept healthy volunteers

Inclusion Criteria:

  1. High Risk: Subject must have co-morbidities such that one cardiologist and two cardiac surgeons agree that predicted risk of operative mortality is ≥15% (and predicted operative mortality or serious, irreversible morbidity risk of < 50%) at 30 days.

    OR

    Extreme Risk: Subject must have co-morbidities such that one cardiologist and two cardiac surgeons agree that medical factors preclude operation, based on a conclusion that the probability of death or serious morbidity exceeds the probability of meaningful improvement. Specifically, the predicted operative risk of death or serious, irreversible morbidity is ≥ 50% at 30 days.

  2. Subject has senile degenerative aortic valve stenosis with:

    • Mean gradient > 40 mmHg, or jet velocity greater than 4.0 m/sec by either resting or dobutamine stress echocardiogram, or simultaneous pressure recordings at cardiac catheterization (either resting or dobutamine stress), AND
    • An initial aortic valve area of ≤ 0.8 cm2 (or aortic valve area index ≤ 0.5 cm2/m2) by resting echocardiogram or simultaneous pressure recordings at cardiac catheterization
  3. Subject is symptomatic from his/her aortic valve stenosis, as demonstrated by New York Heart Association (NYHA) Functional Class II or greater.
  4. The subject or the subject's legal representative has been informed of the nature of the trial, agrees to its provisions and has provided written informed consent as approved by the IRB of the respective clinical site.
  5. The subject and the treating physician agree that the subject will return for all required post-procedure follow-up visits.

Exclusion Criteria:

Clinical

  1. Evidence of an acute myocardial infarction ≤ 30 days before the intended treatment.
  2. Any percutaneous coronary or peripheral interventional procedure performed within 30 days prior to the MCS TAVI procedure including bare metal and drug eluting stents.
  3. Blood dyscrasias as defined: leukopenia (WBC < 1000mm3), thrombocytopenia (platelet count <50,000 cells/mm3), history of bleeding diathesis or coagulopathy.
  4. Untreated clinically significant coronary artery disease requiring revascularization.
  5. Cardiogenic shock manifested by low cardiac output, vasopressor dependence, or mechanical hemodynamic support.
  6. Need for emergency surgery for any reason.
  7. Severe ventricular dysfunction with left ventricular ejection fraction (LVEF) < 20% as measured by resting echocardiogram.
  8. Recent (within 6 months) cerebrovascular accident (CVA) or transient ischemic attack (TIA).
  9. End stage renal disease requiring chronic dialysis or creatinine clearance < 20 cc/min.
  10. Active GI bleeding that would preclude anticoagulation.
  11. A known hypersensitivity or contraindication to any of the following which cannot be adequately pre-medicated:

    • Aspirin
    • Heparin (HIT/HITTS) and bivalirudin
    • Nitinol (titanium or nickel)
    • Ticlopidine and clopidogrel
    • Contrast media
  12. Ongoing sepsis, including active endocarditis.
  13. Subject refuses a blood transfusion.
  14. Life expectancy < 12 months due to associated non-cardiac co-morbid conditions.
  15. Other medical, social, or psychological conditions that in the opinion of an Investigator precludes the subject from appropriate consent.
  16. Severe dementia (resulting in either inability to provide informed consent for the trial/procedure, prevents independent lifestyle outside of a chronic care facility, or will fundamentally complicate rehabilitation from the procedure or compliance with follow-up visits).
  17. Currently participating in an investigational drug or another device trial.
  18. Symptomatic carotid or vertebral artery disease.

    Anatomical

  19. High Risk:Native aortic annulus size < 20 mm or > 29 mm per the baseline diagnostic imaging (until 23mm valve enrollment completion/closure in the CoreValve® US Pivotal Trial-High Risk Cohort)

    OR

    Extreme Risk: Native aortic annulus size < 18 mm or > 29 mm per the baseline diagnostic imaging. (High risk and extreme risk upon 23mm valve enrollment completion/closure in the CoreValve® US Pivotal Trial-High Risk Cohort)

  20. Pre-existing prosthetic heart valve any position.
  21. Mixed aortic valve disease (aortic stenosis and aortic regurgitation with predominant aortic regurgitation (3-4+)).
  22. Moderate to severe (3-4+) or severe (4+) mitral or severe (4+) tricuspid regurgitation.
  23. Moderate to severe mitral stenosis.
  24. Hypertrophic obstructive cardiomyopathy.
  25. Echocardiographic evidence of new or untreated intracardiac mass, thrombus or vegetation.
  26. Severe basal septal hypertrophy with an outflow gradient.
  27. Aortic root angulation (angle between plane of aortic valve annulus and horizontal plane/vertebrae) > 70° (for femoral and left subclavian/axillary access) and > 30° (for right subclavian/axillary access).
  28. Ascending aorta diameter >43 mm if the aortic annulus diameter is 23-29 mm; ascending aortic diameter > 40 mm if the aortic annulus diameter is 20-23 mm; or an ascending aorta diameter > 34 mm if the aortic annulus diameter is 18-20 mm (Extreme Risk only until 23 mm valve enrollment completion/closure in the CoreValve® US Pivotal Trial-High Risk Cohort).
  29. Congenital bicuspid or unicuspid valve verified by echocardiography.
  30. Sinus of valsalva anatomy that would prevent adequate coronary perfusion.

    Vascular

  31. Transarterial access not able to accommodate an 18Fr sheath.

Sites / Locations

  • Banner Good Samaritan
  • University of Southern California University Hospital
  • Kaiser Permanente - Los Angeles Medical Center
  • El Camino Hospital
  • VA Palo Alto Health Care System
  • Hartford Hospital
  • Yale New Haven Hospital
  • Washington Hospital Center / Georgetown Hospital
  • Mount Sinai Medical Center
  • University of Miami Health System / Jackson Memorial Hospital
  • Piedmont Heart Institute
  • Saint Joseph's Hospital of Atlanta
  • Loyola University Medical Center
  • St. Vincent Heart Center of Indiana
  • Iowa Heart Center
  • University of Kansas Hospital
  • Cardiovascular Institute of the South/Terrebonne General
  • Johns Hopkins Hospital
  • Beth Israel Deaconess Medical Center
  • University of Michigan Health Systems
  • Detroit Medical Center Cardiovascular Institute
  • St. John Hospital and Medical Center
  • Spectrum Health Hospitals
  • Morristown Memorial Hospital
  • North Shore University Hospital/ Long Island Jewish Hospital
  • NYU Langone Medical Center
  • The Mount Sinai Medical Center
  • Lenox Hill Hospital
  • St. Francis Hospital
  • Duke University Medical Center
  • Wake Forest University - Baptist Medical Center
  • University Hospitals - Case Medical Center
  • The Ohio State University Medical Center - The Richard M. Ross Heart Hospital
  • Riverside Methodist Hospital
  • Geisinger Medical Center
  • Pinnacle Health
  • University of Pittsburgh Medical Center
  • Vanderbilt University Medical Center
  • Baylor Heart and Vascular Hospital
  • Texas Heart Institute at St. Luke's Episcopal Hospital
  • The Methodist Hospital - The Methodist DeBakey Heart & Vascular Center
  • University of Vermont Medical Center
  • Inova Fairfax Hospital
  • Providence Sacred Heart Medical Center
  • St. Luke's Medical Center - Aurora Health Care

Arms of the Study

Arm 1

Arm 2

Arm 3

Arm Type

Experimental

Experimental

Experimental

Arm Label

Extreme Risk: TAVI Iliofemoral

Extreme Risk: TAVI Non-Iliofemoral

High Risk: TAVI

Arm Description

Extreme Risk Patients: Medtronic CoreValve® System Transcatheter Aortic Valve Implantation (TAVI); Iliofemoral Access

Extreme Risk Patients: Medtronic CoreValve® System Transcatheter Aortic Valve Implantation (TAVI); Non-Iliofemoral Access

High Risk Surgical Patients: Medtronic CoreValve® System Transcatheter Aortic Valve Implantation (TAVI)

Outcomes

Primary Outcome Measures

Extreme Risk: All-cause Death or Major Stroke; High Risk Surgical: All-cause Mortality
All-cause Death or Major Stroke (Extreme Risk- Medtronic CoreValve® System); All-cause Mortality (High Risk Surgical- Medtronic CoreValve® System vs. Surgical Valve)

Secondary Outcome Measures

Major Adverse Cardiovascular and Cerebrovascular Event (MACCE)
MACCE is defined as a composite of: All-Cause Death Myocardial Infarction (MI) All Stroke Reintervention (defined as any cardiac surgery or percutaneous reintervention catheter procedure that repairs, otherwise alters or adjusts, or replaces a previously implanted valve)
The Occurrence of Individual MACCE Components
Individual MACCE Components Include: All Cause Mortality MI All stroke Reintervention (defined as any cardiac surgery or percutaneous reintervention catheter procedure that repairs, otherwise alters or adjusts, or replaces a previously implanted valve)
Major Adverse Events (MAEs)
MAEs Include: MACCE Acute Kidney Injury Cardiac Tamponade Prosthetic Valve Dysfunction Cardiogenic Shock Valve Endocarditis Life-Threatening, Disabling or Major Bleeding Major Vascular Complication Cardiac Perforation Device Migration/Valve Embolism
Conduction Disturbance Requiring Permanent Pacemaker Implantation
Change From Baseline in NYHA Class
Change from baseline (continuous variable). A positive number corresponds to NYHA worsening; a negative number corresponds to NYHA improvement. NYHA Classification: Class I: Subjects with cardiac disease but without resulting limitations of physical activity. Class I: Subjects with cardiac disease resulting in slight limitation of physical activity. Class III: Subjects with cardiac disease resulting in marked limitation of physical activity. Class IV: Subjects with cardiac disease resulting in inability to carry on any physical activity without discomfort.
Change From Baseline in Distance Walked During 6-Minute Walk Test (6MWT)
Change in distance walked during 6MWT from baseline
Ratio of Days Alive Out of Hospital at 365 Days Post Procedure Versus Total Days Alive
Quality of Life (QoL) Change
QoL summary score change from baseline using the following measures: Kansas City Cardiomyopathy Questionnaire (KCCQ): Quantifies physical function, symptoms, social function, self-efficacy and knowledge, and quality of life. Scores are transformed to a range of 0-100, in which higher scores reflect better health status. 12 Item Short Form Health Survey (SF-12): Measures functional health and well-being. Scores are transformed to a range of 0-100, in which higher scores reflect better health status. European QoL (EQ-5D): Measures 5 domains (mobility, self-care, usual activities, pain/discomfort, and anxiety/depression) that can be converted to utilities using an algorithm. Utilities range from 0 to 1, with 1 representing perfect health, and 0 corresponding to the worst imaginable health state.
Echocardiographic Assessment of Valve Performance
Using the following measure: • Effective Orifice Area (EOA) analyzed overall per Extreme Risk or High Risk. Iliofemoral access and non-iliofemoral access are not reported separate because this is a valve performance measurement.
Echocardiographic Assessment of Valve Performance
Using the following measure: • Transvalvular Mean Gradient analyzed overall per Extreme Risk or High Risk. Iliofemoral access and non-iliofemoral access are not reported separate because this is a valve performance measurement.
Echocardiographic Assessment of Valve Performance
Using the following measure: - Degree of Aortic Valve Regurgitation (Transvalvular and Paravalvular) analyzed overall per Extreme Risk or High Risk. Iliofemoral access and non-iliofemoral access are not reported separate because this is a valve performance measurement.
Aortic Valve Hospitalizations
Cardiovascular Deaths and Valve-Related Deaths
Strokes and Transient Ischemic Attacks (TIAs)
Strokes (of any severity) and TIAs
Index Procedure Related MAEs
Length of Index Procedure Hospital Stay
Device Success
Defined as: Successful vascular access, delivery and deployment of the device, and successful retrieval of the delivery system, Correct position of the device in the proper anatomical location (placement in the annulus with no impedance on device function), Intended performance of the prosthetic valve (aortic valve area > 1.2 cm2 for 26, 29 and 31mm valves, ≥ 0.9 cm2 for 23mm valve (by echocardiography using the continuity equation) and mean aortic valve gradient < 20 mmHg or peak velocity < 3 m/sec, without moderate or severe prosthetic valve aortic regurgitation) Only one valve implanted in the proper anatomical location
Procedural Success
Defined as device success and absence of in-hospital MACCE.
Prosthetic Valve Dysfunction (PVD)
PVD was defined according to VARC using the site reported echocardiography assessments including aortic regurgitation (AR) and aortic stenosis (AS) evaluations. Total AR reported as moderate or severe was considered PVD. AS was defined as significant stenosis and considered PVD if one of the following was met: Peak velocity >4 m/s Mean gradient >35 mmHg EOA < 0.8 cm2 TVIV1 / TVIV2 < 0.25

Full Information

First Posted
February 3, 2012
Last Updated
October 21, 2022
Sponsor
Medtronic Cardiovascular
search

1. Study Identification

Unique Protocol Identification Number
NCT01531374
Brief Title
Safety and Efficacy Continued Access Study of the Medtronic CoreValve® System in the Treatment of Symptomatic Severe Aortic Stenosis in Very High Risk Subjects and High Risk Subjects Who Need Aortic Valve Replacement
Official Title
Medtronic CoreValve® Continued Access Study
Study Type
Interventional

2. Study Status

Record Verification Date
October 2022
Overall Recruitment Status
Completed
Study Start Date
February 21, 2012 (Actual)
Primary Completion Date
November 2015 (Actual)
Study Completion Date
November 18, 2019 (Actual)

3. Sponsor/Collaborators

Responsible Party, by Official Title
Sponsor
Name of the Sponsor
Medtronic Cardiovascular

4. Oversight

Data Monitoring Committee
Yes

5. Study Description

Brief Summary
The purpose of the study is to evaluate the safety and efficacy of the Medtronic CoreValve® System in the treatment of symptomatic severe aortic stenosis in subjects who have a predicted very high risk and high risk for aortic valve surgery.

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Severe Aortic Stenosis
Keywords
Valvular Heart Disease, Critical Aortic Stenosis, Severe Aortic Stenosis, Extreme Risk, High Risk, Aortic Valve Replacement

7. Study Design

Primary Purpose
Treatment
Study Phase
Not Applicable
Interventional Study Model
Single Group Assignment
Masking
None (Open Label)
Allocation
Non-Randomized
Enrollment
2777 (Actual)

8. Arms, Groups, and Interventions

Arm Title
Extreme Risk: TAVI Iliofemoral
Arm Type
Experimental
Arm Description
Extreme Risk Patients: Medtronic CoreValve® System Transcatheter Aortic Valve Implantation (TAVI); Iliofemoral Access
Arm Title
Extreme Risk: TAVI Non-Iliofemoral
Arm Type
Experimental
Arm Description
Extreme Risk Patients: Medtronic CoreValve® System Transcatheter Aortic Valve Implantation (TAVI); Non-Iliofemoral Access
Arm Title
High Risk: TAVI
Arm Type
Experimental
Arm Description
High Risk Surgical Patients: Medtronic CoreValve® System Transcatheter Aortic Valve Implantation (TAVI)
Intervention Type
Device
Intervention Name(s)
Medtronic CoreValve® System Transcatheter Aortic Valve Implantation (TAVI)
Primary Outcome Measure Information:
Title
Extreme Risk: All-cause Death or Major Stroke; High Risk Surgical: All-cause Mortality
Description
All-cause Death or Major Stroke (Extreme Risk- Medtronic CoreValve® System); All-cause Mortality (High Risk Surgical- Medtronic CoreValve® System vs. Surgical Valve)
Time Frame
1 year
Secondary Outcome Measure Information:
Title
Major Adverse Cardiovascular and Cerebrovascular Event (MACCE)
Description
MACCE is defined as a composite of: All-Cause Death Myocardial Infarction (MI) All Stroke Reintervention (defined as any cardiac surgery or percutaneous reintervention catheter procedure that repairs, otherwise alters or adjusts, or replaces a previously implanted valve)
Time Frame
30 day, 6 months, and 1 year. The 2-5 year outcome data will be reported once data set is complete.
Title
The Occurrence of Individual MACCE Components
Description
Individual MACCE Components Include: All Cause Mortality MI All stroke Reintervention (defined as any cardiac surgery or percutaneous reintervention catheter procedure that repairs, otherwise alters or adjusts, or replaces a previously implanted valve)
Time Frame
30 day, 6 months, and 1 year. The 2-5 year outcome data will be reported once data set is complete.
Title
Major Adverse Events (MAEs)
Description
MAEs Include: MACCE Acute Kidney Injury Cardiac Tamponade Prosthetic Valve Dysfunction Cardiogenic Shock Valve Endocarditis Life-Threatening, Disabling or Major Bleeding Major Vascular Complication Cardiac Perforation Device Migration/Valve Embolism
Time Frame
30 day, 6 months, and 1 year. The 2-5 year outcome data will be reported once data set is complete.
Title
Conduction Disturbance Requiring Permanent Pacemaker Implantation
Time Frame
30 day, 6 months, and 1 year. The 2-5 year outcome data will be reported once data set is complete.
Title
Change From Baseline in NYHA Class
Description
Change from baseline (continuous variable). A positive number corresponds to NYHA worsening; a negative number corresponds to NYHA improvement. NYHA Classification: Class I: Subjects with cardiac disease but without resulting limitations of physical activity. Class I: Subjects with cardiac disease resulting in slight limitation of physical activity. Class III: Subjects with cardiac disease resulting in marked limitation of physical activity. Class IV: Subjects with cardiac disease resulting in inability to carry on any physical activity without discomfort.
Time Frame
Baseline to 30 days, baseline to 6 months, baseline to 1 year. The 2-5 year outcome data will be reported once data set is complete.
Title
Change From Baseline in Distance Walked During 6-Minute Walk Test (6MWT)
Description
Change in distance walked during 6MWT from baseline
Time Frame
Baseline to 30 days, baseline to 1 year
Title
Ratio of Days Alive Out of Hospital at 365 Days Post Procedure Versus Total Days Alive
Time Frame
1 year
Title
Quality of Life (QoL) Change
Description
QoL summary score change from baseline using the following measures: Kansas City Cardiomyopathy Questionnaire (KCCQ): Quantifies physical function, symptoms, social function, self-efficacy and knowledge, and quality of life. Scores are transformed to a range of 0-100, in which higher scores reflect better health status. 12 Item Short Form Health Survey (SF-12): Measures functional health and well-being. Scores are transformed to a range of 0-100, in which higher scores reflect better health status. European QoL (EQ-5D): Measures 5 domains (mobility, self-care, usual activities, pain/discomfort, and anxiety/depression) that can be converted to utilities using an algorithm. Utilities range from 0 to 1, with 1 representing perfect health, and 0 corresponding to the worst imaginable health state.
Time Frame
30 day, 6 month, 1 year. The 2-5 year outcome data will be reported once data set is complete.
Title
Echocardiographic Assessment of Valve Performance
Description
Using the following measure: • Effective Orifice Area (EOA) analyzed overall per Extreme Risk or High Risk. Iliofemoral access and non-iliofemoral access are not reported separate because this is a valve performance measurement.
Time Frame
30 day, 6 months, and 1 year. The 2-5 year outcome data will be reported once data set is complete.
Title
Echocardiographic Assessment of Valve Performance
Description
Using the following measure: • Transvalvular Mean Gradient analyzed overall per Extreme Risk or High Risk. Iliofemoral access and non-iliofemoral access are not reported separate because this is a valve performance measurement.
Time Frame
30 day, 6 months, and 1 year. The 2-5 year outcome data will be reported once data set is complete.
Title
Echocardiographic Assessment of Valve Performance
Description
Using the following measure: - Degree of Aortic Valve Regurgitation (Transvalvular and Paravalvular) analyzed overall per Extreme Risk or High Risk. Iliofemoral access and non-iliofemoral access are not reported separate because this is a valve performance measurement.
Time Frame
30 day, 6 months, and 1 year. The 2-5 year outcome data will be reported once data set is complete.
Title
Aortic Valve Hospitalizations
Time Frame
30 day, 6 months, and 1 year. The 2-5 year outcome data will be reported once data set is complete.
Title
Cardiovascular Deaths and Valve-Related Deaths
Time Frame
30 day, 6 months, and 1 year. The 2-5 year outcome data will be reported once data set is complete.
Title
Strokes and Transient Ischemic Attacks (TIAs)
Description
Strokes (of any severity) and TIAs
Time Frame
30 day, 6 months, and 1 year. The 2-5 year outcome data will be reported once data set is complete.
Title
Index Procedure Related MAEs
Time Frame
Procedure
Title
Length of Index Procedure Hospital Stay
Time Frame
Number of days from admission to discharge
Title
Device Success
Description
Defined as: Successful vascular access, delivery and deployment of the device, and successful retrieval of the delivery system, Correct position of the device in the proper anatomical location (placement in the annulus with no impedance on device function), Intended performance of the prosthetic valve (aortic valve area > 1.2 cm2 for 26, 29 and 31mm valves, ≥ 0.9 cm2 for 23mm valve (by echocardiography using the continuity equation) and mean aortic valve gradient < 20 mmHg or peak velocity < 3 m/sec, without moderate or severe prosthetic valve aortic regurgitation) Only one valve implanted in the proper anatomical location
Time Frame
Number of days from admission to discharge
Title
Procedural Success
Description
Defined as device success and absence of in-hospital MACCE.
Time Frame
Number of days from admission to discharge
Title
Prosthetic Valve Dysfunction (PVD)
Description
PVD was defined according to VARC using the site reported echocardiography assessments including aortic regurgitation (AR) and aortic stenosis (AS) evaluations. Total AR reported as moderate or severe was considered PVD. AS was defined as significant stenosis and considered PVD if one of the following was met: Peak velocity >4 m/s Mean gradient >35 mmHg EOA < 0.8 cm2 TVIV1 / TVIV2 < 0.25
Time Frame
30 day, 6 months, and 1 year. The 2-5 year outcome data will be reported once data set is complete.

10. Eligibility

Sex
All
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria: High Risk: Subject must have co-morbidities such that one cardiologist and two cardiac surgeons agree that predicted risk of operative mortality is ≥15% (and predicted operative mortality or serious, irreversible morbidity risk of < 50%) at 30 days. OR Extreme Risk: Subject must have co-morbidities such that one cardiologist and two cardiac surgeons agree that medical factors preclude operation, based on a conclusion that the probability of death or serious morbidity exceeds the probability of meaningful improvement. Specifically, the predicted operative risk of death or serious, irreversible morbidity is ≥ 50% at 30 days. Subject has senile degenerative aortic valve stenosis with: Mean gradient > 40 mmHg, or jet velocity greater than 4.0 m/sec by either resting or dobutamine stress echocardiogram, or simultaneous pressure recordings at cardiac catheterization (either resting or dobutamine stress), AND An initial aortic valve area of ≤ 0.8 cm2 (or aortic valve area index ≤ 0.5 cm2/m2) by resting echocardiogram or simultaneous pressure recordings at cardiac catheterization Subject is symptomatic from his/her aortic valve stenosis, as demonstrated by New York Heart Association (NYHA) Functional Class II or greater. The subject or the subject's legal representative has been informed of the nature of the trial, agrees to its provisions and has provided written informed consent as approved by the IRB of the respective clinical site. The subject and the treating physician agree that the subject will return for all required post-procedure follow-up visits. Exclusion Criteria: Clinical Evidence of an acute myocardial infarction ≤ 30 days before the intended treatment. Any percutaneous coronary or peripheral interventional procedure performed within 30 days prior to the MCS TAVI procedure including bare metal and drug eluting stents. Blood dyscrasias as defined: leukopenia (WBC < 1000mm3), thrombocytopenia (platelet count <50,000 cells/mm3), history of bleeding diathesis or coagulopathy. Untreated clinically significant coronary artery disease requiring revascularization. Cardiogenic shock manifested by low cardiac output, vasopressor dependence, or mechanical hemodynamic support. Need for emergency surgery for any reason. Severe ventricular dysfunction with left ventricular ejection fraction (LVEF) < 20% as measured by resting echocardiogram. Recent (within 6 months) cerebrovascular accident (CVA) or transient ischemic attack (TIA). End stage renal disease requiring chronic dialysis or creatinine clearance < 20 cc/min. Active GI bleeding that would preclude anticoagulation. A known hypersensitivity or contraindication to any of the following which cannot be adequately pre-medicated: Aspirin Heparin (HIT/HITTS) and bivalirudin Nitinol (titanium or nickel) Ticlopidine and clopidogrel Contrast media Ongoing sepsis, including active endocarditis. Subject refuses a blood transfusion. Life expectancy < 12 months due to associated non-cardiac co-morbid conditions. Other medical, social, or psychological conditions that in the opinion of an Investigator precludes the subject from appropriate consent. Severe dementia (resulting in either inability to provide informed consent for the trial/procedure, prevents independent lifestyle outside of a chronic care facility, or will fundamentally complicate rehabilitation from the procedure or compliance with follow-up visits). Currently participating in an investigational drug or another device trial. Symptomatic carotid or vertebral artery disease. Anatomical High Risk:Native aortic annulus size < 20 mm or > 29 mm per the baseline diagnostic imaging (until 23mm valve enrollment completion/closure in the CoreValve® US Pivotal Trial-High Risk Cohort) OR Extreme Risk: Native aortic annulus size < 18 mm or > 29 mm per the baseline diagnostic imaging. (High risk and extreme risk upon 23mm valve enrollment completion/closure in the CoreValve® US Pivotal Trial-High Risk Cohort) Pre-existing prosthetic heart valve any position. Mixed aortic valve disease (aortic stenosis and aortic regurgitation with predominant aortic regurgitation (3-4+)). Moderate to severe (3-4+) or severe (4+) mitral or severe (4+) tricuspid regurgitation. Moderate to severe mitral stenosis. Hypertrophic obstructive cardiomyopathy. Echocardiographic evidence of new or untreated intracardiac mass, thrombus or vegetation. Severe basal septal hypertrophy with an outflow gradient. Aortic root angulation (angle between plane of aortic valve annulus and horizontal plane/vertebrae) > 70° (for femoral and left subclavian/axillary access) and > 30° (for right subclavian/axillary access). Ascending aorta diameter >43 mm if the aortic annulus diameter is 23-29 mm; ascending aortic diameter > 40 mm if the aortic annulus diameter is 20-23 mm; or an ascending aorta diameter > 34 mm if the aortic annulus diameter is 18-20 mm (Extreme Risk only until 23 mm valve enrollment completion/closure in the CoreValve® US Pivotal Trial-High Risk Cohort). Congenital bicuspid or unicuspid valve verified by echocardiography. Sinus of valsalva anatomy that would prevent adequate coronary perfusion. Vascular Transarterial access not able to accommodate an 18Fr sheath.
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
David H Adams, MD
Organizational Affiliation
Icahn School of Medicine at Mount Sinai
Official's Role
Principal Investigator
Facility Information:
Facility Name
Banner Good Samaritan
City
Phoenix
State/Province
Arizona
ZIP/Postal Code
85006
Country
United States
Facility Name
University of Southern California University Hospital
City
Los Angeles
State/Province
California
ZIP/Postal Code
90033
Country
United States
Facility Name
Kaiser Permanente - Los Angeles Medical Center
City
Los Angeles
State/Province
California
ZIP/Postal Code
90072
Country
United States
Facility Name
El Camino Hospital
City
Mountain View
State/Province
California
ZIP/Postal Code
94040
Country
United States
Facility Name
VA Palo Alto Health Care System
City
Palo Alto
State/Province
California
ZIP/Postal Code
94304
Country
United States
Facility Name
Hartford Hospital
City
Hartford
State/Province
Connecticut
ZIP/Postal Code
06102
Country
United States
Facility Name
Yale New Haven Hospital
City
New Haven
State/Province
Connecticut
ZIP/Postal Code
06520
Country
United States
Facility Name
Washington Hospital Center / Georgetown Hospital
City
Washington
State/Province
District of Columbia
ZIP/Postal Code
20010
Country
United States
Facility Name
Mount Sinai Medical Center
City
Miami Beach
State/Province
Florida
ZIP/Postal Code
33140
Country
United States
Facility Name
University of Miami Health System / Jackson Memorial Hospital
City
Miami
State/Province
Florida
ZIP/Postal Code
33136
Country
United States
Facility Name
Piedmont Heart Institute
City
Atlanta
State/Province
Georgia
ZIP/Postal Code
30309
Country
United States
Facility Name
Saint Joseph's Hospital of Atlanta
City
Atlanta
State/Province
Georgia
ZIP/Postal Code
30342
Country
United States
Facility Name
Loyola University Medical Center
City
Maywood
State/Province
Illinois
ZIP/Postal Code
60153
Country
United States
Facility Name
St. Vincent Heart Center of Indiana
City
Indianapolis
State/Province
Indiana
ZIP/Postal Code
46290
Country
United States
Facility Name
Iowa Heart Center
City
Des Moines
State/Province
Iowa
ZIP/Postal Code
50314
Country
United States
Facility Name
University of Kansas Hospital
City
Kansas City
State/Province
Kansas
ZIP/Postal Code
66160
Country
United States
Facility Name
Cardiovascular Institute of the South/Terrebonne General
City
Houma
State/Province
Louisiana
ZIP/Postal Code
70360
Country
United States
Facility Name
Johns Hopkins Hospital
City
Baltimore
State/Province
Maryland
ZIP/Postal Code
21287
Country
United States
Facility Name
Beth Israel Deaconess Medical Center
City
Boston
State/Province
Massachusetts
ZIP/Postal Code
02215
Country
United States
Facility Name
University of Michigan Health Systems
City
Ann Arbor
State/Province
Michigan
ZIP/Postal Code
48109
Country
United States
Facility Name
Detroit Medical Center Cardiovascular Institute
City
Detroit
State/Province
Michigan
ZIP/Postal Code
48201
Country
United States
Facility Name
St. John Hospital and Medical Center
City
Detroit
State/Province
Michigan
ZIP/Postal Code
48236
Country
United States
Facility Name
Spectrum Health Hospitals
City
Grand Rapids
State/Province
Michigan
ZIP/Postal Code
49503
Country
United States
Facility Name
Morristown Memorial Hospital
City
Morristown
State/Province
New Jersey
ZIP/Postal Code
07962
Country
United States
Facility Name
North Shore University Hospital/ Long Island Jewish Hospital
City
Manhasset
State/Province
New York
ZIP/Postal Code
11030
Country
United States
Facility Name
NYU Langone Medical Center
City
New York
State/Province
New York
ZIP/Postal Code
10016
Country
United States
Facility Name
The Mount Sinai Medical Center
City
New York
State/Province
New York
ZIP/Postal Code
10029
Country
United States
Facility Name
Lenox Hill Hospital
City
New York
State/Province
New York
ZIP/Postal Code
10075
Country
United States
Facility Name
St. Francis Hospital
City
Roslyn
State/Province
New York
ZIP/Postal Code
11576
Country
United States
Facility Name
Duke University Medical Center
City
Durham
State/Province
North Carolina
ZIP/Postal Code
27710
Country
United States
Facility Name
Wake Forest University - Baptist Medical Center
City
Winston-Salem
State/Province
North Carolina
ZIP/Postal Code
27157
Country
United States
Facility Name
University Hospitals - Case Medical Center
City
Cleveland
State/Province
Ohio
ZIP/Postal Code
44106
Country
United States
Facility Name
The Ohio State University Medical Center - The Richard M. Ross Heart Hospital
City
Columbus
State/Province
Ohio
ZIP/Postal Code
43210
Country
United States
Facility Name
Riverside Methodist Hospital
City
Columbus
State/Province
Ohio
ZIP/Postal Code
43214
Country
United States
Facility Name
Geisinger Medical Center
City
Danville
State/Province
Pennsylvania
ZIP/Postal Code
17822
Country
United States
Facility Name
Pinnacle Health
City
Harrisburg
State/Province
Pennsylvania
ZIP/Postal Code
17043
Country
United States
Facility Name
University of Pittsburgh Medical Center
City
Pittsburgh
State/Province
Pennsylvania
ZIP/Postal Code
15213
Country
United States
Facility Name
Vanderbilt University Medical Center
City
Nashville
State/Province
Tennessee
ZIP/Postal Code
37232
Country
United States
Facility Name
Baylor Heart and Vascular Hospital
City
Dallas
State/Province
Texas
ZIP/Postal Code
75226
Country
United States
Facility Name
Texas Heart Institute at St. Luke's Episcopal Hospital
City
Houston
State/Province
Texas
ZIP/Postal Code
77030
Country
United States
Facility Name
The Methodist Hospital - The Methodist DeBakey Heart & Vascular Center
City
Houston
State/Province
Texas
ZIP/Postal Code
77030
Country
United States
Facility Name
University of Vermont Medical Center
City
Burlington
State/Province
Vermont
ZIP/Postal Code
05458
Country
United States
Facility Name
Inova Fairfax Hospital
City
Falls Church
State/Province
Virginia
ZIP/Postal Code
22042
Country
United States
Facility Name
Providence Sacred Heart Medical Center
City
Spokane
State/Province
Washington
ZIP/Postal Code
99204
Country
United States
Facility Name
St. Luke's Medical Center - Aurora Health Care
City
Milwaukee
State/Province
Wisconsin
ZIP/Postal Code
53215
Country
United States

12. IPD Sharing Statement

Citations:
PubMed Identifier
34529944
Citation
Butala NM, Song Y, Shen C, Cohen DJ, Yeh RW. Effect of intensive versus limited monitoring on clinical trial conduct and outcomes: A randomized trial. Am Heart J. 2022 Jan;243:77-86. doi: 10.1016/j.ahj.2021.09.002. Epub 2021 Sep 14.
Results Reference
derived
PubMed Identifier
30341970
Citation
Pineda AM, Kevin Harrison J, Kleiman NS, Reardon MJ, Conte JV, O'Hair DP, Chetcuti SJ, Huang J, Yakubov SJ, Popma JJ, Beohar N. Clinical impact of baseline chronic kidney disease in patients undergoing transcatheter or surgical aortic valve replacement. Catheter Cardiovasc Interv. 2019 Mar 1;93(4):740-748. doi: 10.1002/ccd.27928. Epub 2018 Oct 20.
Results Reference
derived
PubMed Identifier
27601429
Citation
Kleiman NS, Maini BJ, Reardon MJ, Conte J, Katz S, Rajagopal V, Kauten J, Hartman A, McKay R, Hagberg R, Huang J, Popma J; CoreValve Investigators. Neurological Events Following Transcatheter Aortic Valve Replacement and Their Predictors: A Report From the CoreValve Trials. Circ Cardiovasc Interv. 2016 Sep;9(9):e003551. doi: 10.1161/CIRCINTERVENTIONS.115.003551. Erratum In: Circ Cardiovasc Interv. 2016 Nov;9(11):
Results Reference
derived

Learn more about this trial

Safety and Efficacy Continued Access Study of the Medtronic CoreValve® System in the Treatment of Symptomatic Severe Aortic Stenosis in Very High Risk Subjects and High Risk Subjects Who Need Aortic Valve Replacement

We'll reach out to this number within 24 hrs