Specific Screw Holes Locating Surgical Guide and Pre-bent Plates
Mandibular Fractures
About this trial
This is an interventional other trial for Mandibular Fractures focused on measuring class III
Eligibility Criteria
Inclusion Criteria:
- Patients with delayed and isolated mandibular class III fracture needs open reduction and internal fixation.
- Patients with medical history that did not hinder plate placement (uncontrolled diabetes) and adequate proper oral hygiene.
- Both genders males and females will be included.
Exclusion Criteria:
• General contraindications to surgery.
- Patients with fresh fractures (mobile segments).
- Patients with unfavourable nor comminuted fractures.
- Subjected to irradiation in the head and neck area less than 1 year before fixation.
- Untreated periodontitis.
- Poor oral hygiene and motivation.
- Uncontrolled diabetes.
- Pregnant or nursing.
- Substance abuse.
- Psychiatric problems or unrealistic expectations.
- Severe bruxism or clenching.
- Immunosuppressed or immunocompromised.
- Treated or under treatment with intravenous amino-bisphosphonates.
- Patients participating in other studies, if the present protocol could not be properly followed.
Sites / Locations
Arms of the Study
Arm 1
Arm 2
Experimental
Other
specific screw holes locating surgical guide and pre-bent plates
classical reduction and fixation
Put the specific screw holes locating device in place and drill the screw holes, remove the screw holes locating device and mobilize the segments then apply the pre-bent plates and fix it with screw for passive reduction of the segments. Then suture the mentalis muscle then the mucosa.
mobilize the broken segment first, Arch bar was made to achieve proper occlusion put the compression plate on the inferior border and remove it for further bending using plate pliers for further accommodation of the plate on the inferior border the fix it in place using compression and tension plate.