Stability of Contemporary Knee Arthroplasty
Primary Purpose
Knee Osteoarthritis
Status
Active
Phase
Not Applicable
Locations
Norway
Study Type
Interventional
Intervention
Medacta International, GMK Sphere medially stabilized knee
Sponsored by
About this trial
This is an interventional treatment trial for Knee Osteoarthritis focused on measuring Total Knee Arthroplasty (TKA), Total Knee Replacement (TKR), Kinematics, RSA, Knee arthroplasty, Implant stability, Migration, Wear, Medial pivot
Eligibility Criteria
Inclusion Criteria:
- Patients with knee osteoarthritis
Exclusion Criteria:
- Preoperative severe deformity (Femoro-tibial angle < 175°or > 190°measured on a full-length leg image at weight bearing)
- Preoperative flexion contracture more than 15°
- Preoperative limited range of motion under anesthetics (less than 110°)
- Less than 50 or more than 75 years of age at the time of surgery
- Use of walking aids because of other musculoskeletal and neuromuscular problems
- Preoperative diagnosis other than osteoarthritis and avascular necrosis (e.g. rheumatoid arthritis, tumors)
- Revision arthroplasty
- Obesity with BMI >35
- Impaired collateral ligaments
- Malposition of femoral and tibial implants (Internally rotated or more than 10° externally rotated implants will be excluded. The rotation of femoral implant is measured on postoperative CT images in reference to surgical epicondylar line. The rotation of tibial implant is determined according to Berger's measurement)
- Postoperative revision surgery due to deep wound infection
Sites / Locations
- Oslo University Hospital
Arms of the Study
Arm 1
Arm Type
Other
Arm Label
GMK Sphere
Arm Description
Patients receive a GMK Sphere Total Knee Replacement.
Outcomes
Primary Outcome Measures
Stability of the GMK Sphere prosthesis measured by Radiostereometric Analysis (RSA)
Stability of the implant is measured in mm after 5 years (Maximum Total Point Motion in mm, MTPM)
Secondary Outcome Measures
Knee Society Score (KSS)
Patient reported outcome measures
Forgotten Joint Score 12 (FJS-12)
Patient reported outcome measures
Knee injury and Osteoarthritis Outcome Score (KOOS)
Patient reported outcome measures
Range of motion (ROM)
Clinical measurement using goniometer
Hip-knee-ankle angle (HKA-angle)
The axis of the lower extremity after knee arthroplasty
CT-rotation of implants
Evaluation of tibia implant rotation using Berger's method
Stability of the GMK Sphere prosthesis
Stability of the implant is measured in mm and degrees after 5 years using RSA (translation and rotasjon for x, y and z)
Full Information
NCT ID
NCT02861794
First Posted
April 28, 2016
Last Updated
December 9, 2021
Sponsor
Oslo University Hospital
Collaborators
Helse More and Romsdal Trust, Medacta International SA
1. Study Identification
Unique Protocol Identification Number
NCT02861794
Brief Title
Stability of Contemporary Knee Arthroplasty
Official Title
Evaluation of Early Migration of Medially Stabilized Arthroplasty as a Predictor of Long Time Survivorship (Implant Design Study)
Study Type
Interventional
2. Study Status
Record Verification Date
December 2021
Overall Recruitment Status
Active, not recruiting
Study Start Date
May 2016 (Actual)
Primary Completion Date
December 31, 2022 (Anticipated)
Study Completion Date
December 31, 2022 (Anticipated)
3. Sponsor/Collaborators
Responsible Party, by Official Title
Principal Investigator
Name of the Sponsor
Oslo University Hospital
Collaborators
Helse More and Romsdal Trust, Medacta International SA
4. Oversight
Studies a U.S. FDA-regulated Drug Product
No
Studies a U.S. FDA-regulated Device Product
No
Data Monitoring Committee
Yes
5. Study Description
Brief Summary
Total joint replacement is an efficacious treatment for osteoarthritis of hips and knees. Both total knee replacement (TKR) and total hip replacements (THR) have excellent implant survivorship. However, patient satisfaction is lower in TKR than THR. A possible cause of the discrepancy is the unnatural knee kinematics after TKR. Various implants designs have been developed to solve the problem. However, most of their designs are based on experimental data and little has been studied about their actual performance in vivo. In this study, the investigators will analyze the in vivo stability of the Global Medacta Knee Sphere (GMK Sphere) implant. Migration of the implants will be monitored with a high precision measuring method called Radiostereometric Analysis (RSA). The investigators assume the investigators study will contribute the development of more satisfying knee implants.
Detailed Description
Worldwide the number of patients requiring treatment for osteoarthritis is increasing due to increasing obesity, an ageing population and a high demanding younger population. Learmonth describes hip arthroplasty as the "operation of the century" because patients are highly satisfied with pain relief and function after the procedure. Knee arthroplasties have in recent years also shown promising results and have surpassed hip arthroplasty in frequency in western countries. However, patient satisfaction is not as high. Reported problems are insufficient function and persistent pain. On the other hand, knee arthroplasties are increasingly implanted in younger and more active patients who require high function and quality of life. Improvement of knee implants is an urgent issue in the field of orthopaedic research.
Knee Kinematics and implant designs
A possible cause of lower function of replaced knees is the unnatural postoperative knee kinematics. Kinematics of replaced knees is closely related to their function. Studies show that replaced knees with excellent flexion angles have kinematic similarities to normal knees and malalignments of implants can cause postoperative pain.
Compared to hip joints which are simple ball-and socket joints, the kinematics of knee joints is more complex. The kinematics are a combination of a rolling and gliding motion of the femoral condyles and rotation of the tibia. Based on the kinematics of the normal knee joint, various attempts have been made on the design of knee implants to reconstruct normal kinematics after replacement surgery. All of these implants have satisfying survivorship, but unicondylar arthroplasty which retains both cruciate ligaments has the best clinical results with survivorship at 15 years 93%. In total knee replacement (TKR) the Anterior Cruciate Ligament (ACL) and possibly the Posterior Cruciate Ligament (PCL) are sacrified. When sacrificing the one or both of the cruciate ligaments, natural knee kinematics are affected. The function of the cruciate ligaments can be mimicked by different designs of the tibial insert.
The most used knee implant in Norway, the NexGen Cruciate-retaining (CR) implant design, does not retain the ACL and does not mimic natural knee kinematics. The tibial insert of the medial pivot implant design (GMK Sphere) has a constrained medial ball in socket joint and at the same time allows lateral anterioposterior movement. This new design was developed by a group of dedicated researchers. The design intention is to resemble the function of the cruciate ligaments and at the same time allow for lateral anterioposterior movement (rollback).
Small alterations in implant design can influence the survival of implants. The final design of the GMK Sphere was introduced in 2012. New implants should be monitored and assessed in small, controlled trials with high precision measuring methods.
Analytical Method
RSA has been used in orthopedic research fields since 1970s. The original application of this method was for the evaluation of implant migration (i.e. fixation) and polyethylene wear of artificial joints using static X-ray pictures. Clinically relevant association between early migration of tibial implants detected by RSA and late revision for loosening has been reported. Also, attempts to measure in vivo polyethylene wear have been reported using RSA.
Purpose of this study
The aim of this study is to analyse the in vivo performance (e.g. stability) of a medially stabilized knee arthroplasty implant (Medacta International, GMK Sphere) using static RSA method over a period of 5 years. 2-year results have already been analysed and are inconclusive in regards to migration as the implant is apparently stable, but shows greater than anticipated movement. Mid-term follow-up (5-year) is therefore essential to evaluate migration of this implant. We therefore wish to obtain 5-year follow-ups of these patients.
Additionally, the investigators will analyse the wear in the ball and socket (medial) side of the tibiofemoral articulation.
30 patients will go through stability and wear testing with static RSA.
This study will contribute to the safety for patients with this new implant by providing basic knowledge of this knee arthroplasty and promoting further development of knee implant designs.
6. Conditions and Keywords
Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Knee Osteoarthritis
Keywords
Total Knee Arthroplasty (TKA), Total Knee Replacement (TKR), Kinematics, RSA, Knee arthroplasty, Implant stability, Migration, Wear, Medial pivot
7. Study Design
Primary Purpose
Treatment
Study Phase
Not Applicable
Interventional Study Model
Single Group Assignment
Model Description
Prospective interventional single group cohort study
Masking
None (Open Label)
Masking Description
Non-blind
Allocation
N/A
Enrollment
31 (Anticipated)
8. Arms, Groups, and Interventions
Arm Title
GMK Sphere
Arm Type
Other
Arm Description
Patients receive a GMK Sphere Total Knee Replacement.
Intervention Type
Procedure
Intervention Name(s)
Medacta International, GMK Sphere medially stabilized knee
Intervention Description
Total Knee Replacement
Primary Outcome Measure Information:
Title
Stability of the GMK Sphere prosthesis measured by Radiostereometric Analysis (RSA)
Description
Stability of the implant is measured in mm after 5 years (Maximum Total Point Motion in mm, MTPM)
Time Frame
5 years
Secondary Outcome Measure Information:
Title
Knee Society Score (KSS)
Description
Patient reported outcome measures
Time Frame
5 years
Title
Forgotten Joint Score 12 (FJS-12)
Description
Patient reported outcome measures
Time Frame
5 years
Title
Knee injury and Osteoarthritis Outcome Score (KOOS)
Description
Patient reported outcome measures
Time Frame
5 years
Title
Range of motion (ROM)
Description
Clinical measurement using goniometer
Time Frame
5 years
Title
Hip-knee-ankle angle (HKA-angle)
Description
The axis of the lower extremity after knee arthroplasty
Time Frame
5 years
Title
CT-rotation of implants
Description
Evaluation of tibia implant rotation using Berger's method
Time Frame
5 years
Title
Stability of the GMK Sphere prosthesis
Description
Stability of the implant is measured in mm and degrees after 5 years using RSA (translation and rotasjon for x, y and z)
Time Frame
5 years
10. Eligibility
Sex
All
Minimum Age & Unit of Time
50 Years
Maximum Age & Unit of Time
75 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria:
Patients with knee osteoarthritis
Exclusion Criteria:
Preoperative severe deformity (Femoro-tibial angle < 175°or > 190°measured on a full-length leg image at weight bearing)
Preoperative flexion contracture more than 15°
Preoperative limited range of motion under anesthetics (less than 110°)
Less than 50 or more than 75 years of age at the time of surgery
Use of walking aids because of other musculoskeletal and neuromuscular problems
Preoperative diagnosis other than osteoarthritis and avascular necrosis (e.g. rheumatoid arthritis, tumors)
Revision arthroplasty
Obesity with BMI >35
Impaired collateral ligaments
Malposition of femoral and tibial implants (Internally rotated or more than 10° externally rotated implants will be excluded. The rotation of femoral implant is measured on postoperative CT images in reference to surgical epicondylar line. The rotation of tibial implant is determined according to Berger's measurement)
Postoperative revision surgery due to deep wound infection
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Stephan Maximillian Røhrl, MD, PhD
Organizational Affiliation
Center for Implant and Radiostereometric Research Oslo (CIRRO)
Official's Role
Study Director
First Name & Middle Initial & Last Name & Degree
Frank-David Oehrn, MD
Organizational Affiliation
Kristiansund Hospital, Helse More and Romsdal Trust
Official's Role
Principal Investigator
First Name & Middle Initial & Last Name & Degree
Lars Harald William Engseth, MD, PhD
Organizational Affiliation
Center for Implant and Radiostereometric Research Oslo (CIRRO)
Official's Role
Principal Investigator
Facility Information:
Facility Name
Oslo University Hospital
City
Oslo
ZIP/Postal Code
0470
Country
Norway
12. IPD Sharing Statement
Plan to Share IPD
No
Citations:
PubMed Identifier
17403800
Citation
Kurtz S, Ong K, Lau E, Mowat F, Halpern M. Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 2030. J Bone Joint Surg Am. 2007 Apr;89(4):780-5. doi: 10.2106/JBJS.F.00222.
Results Reference
background
PubMed Identifier
19360453
Citation
Kurtz SM, Lau E, Ong K, Zhao K, Kelly M, Bozic KJ. Future young patient demand for primary and revision joint replacement: national projections from 2010 to 2030. Clin Orthop Relat Res. 2009 Oct;467(10):2606-12. doi: 10.1007/s11999-009-0834-6. Epub 2009 Apr 10.
Results Reference
background
PubMed Identifier
17964352
Citation
Learmonth ID, Young C, Rorabeck C. The operation of the century: total hip replacement. Lancet. 2007 Oct 27;370(9597):1508-19. doi: 10.1016/S0140-6736(07)60457-7.
Results Reference
background
PubMed Identifier
21518317
Citation
Dieppe P, Lim K, Lohmander S. Who should have knee joint replacement surgery for osteoarthritis? Int J Rheum Dis. 2011 May;14(2):175-80. doi: 10.1111/j.1756-185X.2011.01611.x.
Results Reference
background
PubMed Identifier
22398175
Citation
Carr AJ, Robertsson O, Graves S, Price AJ, Arden NK, Judge A, Beard DJ. Knee replacement. Lancet. 2012 Apr 7;379(9823):1331-40. doi: 10.1016/S0140-6736(11)60752-6. Epub 2012 Mar 6.
Results Reference
background
PubMed Identifier
23459843
Citation
Hawker GA, Badley EM, Borkhoff CM, Croxford R, Davis AM, Dunn S, Gignac MA, Jaglal SB, Kreder HJ, Sale JE. Which patients are most likely to benefit from total joint arthroplasty? Arthritis Rheum. 2013 May;65(5):1243-52. doi: 10.1002/art.37901.
Results Reference
background
PubMed Identifier
22178464
Citation
Wylde V, Jeffery A, Dieppe P, Gooberman-Hill R. The assessment of persistent pain after joint replacement. Osteoarthritis Cartilage. 2012 Feb;20(2):102-5. doi: 10.1016/j.joca.2011.11.011. Epub 2011 Nov 30.
Results Reference
background
PubMed Identifier
23218428
Citation
Ravi B, Croxford R, Reichmann WM, Losina E, Katz JN, Hawker GA. The changing demographics of total joint arthroplasty recipients in the United States and Ontario from 2001 to 2007. Best Pract Res Clin Rheumatol. 2012 Oct;26(5):637-47. doi: 10.1016/j.berh.2012.07.014.
Results Reference
background
PubMed Identifier
20223054
Citation
Ibrahim T, Bloch B, Esler CN, Abrams KR, Harper WM. Temporal trends in primary total hip and knee arthroplasty surgery: results from a UK regional joint register, 1991-2004. Ann R Coll Surg Engl. 2010 Apr;92(3):231-5. doi: 10.1308/003588410X12628812458572. Epub 2010 Mar 10.
Results Reference
background
PubMed Identifier
23122654
Citation
Watanabe T, Ishizuki M, Muneta T, Banks SA. Knee kinematics in anterior cruciate ligament-substituting arthroplasty with or without the posterior cruciate ligament. J Arthroplasty. 2013 Apr;28(4):548-52. doi: 10.1016/j.arth.2012.06.030. Epub 2012 Oct 31.
Results Reference
background
PubMed Identifier
23140906
Citation
Bell SW, Young P, Drury C, Smith J, Anthony I, Jones B, Blyth M, McLean A. Component rotational alignment in unexplained painful primary total knee arthroplasty. Knee. 2014 Jan;21(1):272-7. doi: 10.1016/j.knee.2012.09.011. Epub 2012 Nov 7.
Results Reference
background
PubMed Identifier
14669200
Citation
Smith PN, Refshauge KM, Scarvell JM. Development of the concepts of knee kinematics. Arch Phys Med Rehabil. 2003 Dec;84(12):1895-902. doi: 10.1016/s0003-9993(03)00281-8.
Results Reference
background
PubMed Identifier
21909722
Citation
Chalidis BE, Sachinis NP, Papadopoulos P, Petsatodis E, Christodoulou AG, Petsatodis G. Long-term results of posterior-cruciate-retaining Genesis I total knee arthroplasty. J Orthop Sci. 2011 Nov;16(6):726-31. doi: 10.1007/s00776-011-0152-1. Epub 2011 Sep 10.
Results Reference
background
PubMed Identifier
9418624
Citation
Font-Rodriguez DE, Scuderi GR, Insall JN. Survivorship of cemented total knee arthroplasty. Clin Orthop Relat Res. 1997 Dec;(345):79-86.
Results Reference
background
PubMed Identifier
23814243
Citation
Sabouret P, Lavoie F, Cloutier JM. Total knee replacement with retention of both cruciate ligaments: a 22-year follow-up study. Bone Joint J. 2013 Jul;95-B(7):917-22. doi: 10.1302/0301-620X.95B7.30904.
Results Reference
background
PubMed Identifier
15930935
Citation
Price AJ, Waite JC, Svard U. Long-term clinical results of the medial Oxford unicompartmental knee arthroplasty. Clin Orthop Relat Res. 2005 Jun;(435):171-80. doi: 10.1097/00003086-200506000-00024.
Results Reference
background
PubMed Identifier
10703097
Citation
Malchau H. Introducing new technology: a stepwise algorithm. Spine (Phila Pa 1976). 2000 Feb 1;25(3):285. doi: 10.1097/00007632-200002010-00004. No abstract available.
Results Reference
background
PubMed Identifier
20888183
Citation
Malchau H, Bragdon CR, Muratoglu OK. The stepwise introduction of innovation into orthopedic surgery: the next level of dilemmas. J Arthroplasty. 2011 Sep;26(6):825-31. doi: 10.1016/j.arth.2010.08.007. Epub 2010 Oct 2.
Results Reference
background
PubMed Identifier
11132285
Citation
Iwaki H, Pinskerova V, Freeman MA. Tibiofemoral movement 1: the shapes and relative movements of the femur and tibia in the unloaded cadaver knee. J Bone Joint Surg Br. 2000 Nov;82(8):1189-95. doi: 10.1302/0301-620x.82b8.10717.
Results Reference
background
PubMed Identifier
15330038
Citation
Pinskerova V, Johal P, Nakagawa S, Sosna A, Williams A, Gedroyc W, Freeman MA. Does the femur roll-back with flexion? J Bone Joint Surg Br. 2004 Aug;86(6):925-31. doi: 10.1302/0301-620x.86b6.14589.
Results Reference
background
PubMed Identifier
19483242
Citation
Pinskerova V, Samuelson KM, Stammers J, Maruthainar K, Sosna A, Freeman MA. The knee in full flexion: an anatomical study. J Bone Joint Surg Br. 2009 Jun;91(6):830-4. doi: 10.1302/0301-620X.91B6.22319.
Results Reference
background
PubMed Identifier
11132287
Citation
Nakagawa S, Kadoya Y, Todo S, Kobayashi A, Sakamoto H, Freeman MA, Yamano Y. Tibiofemoral movement 3: full flexion in the living knee studied by MRI. J Bone Joint Surg Br. 2000 Nov;82(8):1199-200. doi: 10.1302/0301-620x.82b8.10718.
Results Reference
background
PubMed Identifier
12771815
Citation
Freeman MA, Pinskerova V. The movement of the knee studied by magnetic resonance imaging. Clin Orthop Relat Res. 2003 May;(410):35-43. doi: 10.1097/01.blo.0000063598.67412.0d.
Results Reference
background
PubMed Identifier
15598446
Citation
Freeman MA, Pinskerova V. The movement of the normal tibio-femoral joint. J Biomech. 2005 Feb;38(2):197-208. doi: 10.1016/j.jbiomech.2004.02.006.
Results Reference
background
PubMed Identifier
23795579
Citation
Dahl J, Snorrason F, Nordsletten L, Rohrl SM. More than 50% reduction of wear in polyethylene liners with alumina heads compared to cobalt-chrome heads in hip replacements: a 10-year follow-up with radiostereometry in 43 hips. Acta Orthop. 2013 Aug;84(4):360-4. doi: 10.3109/17453674.2013.810516. Epub 2013 Jun 25.
Results Reference
background
PubMed Identifier
22126919
Citation
Figved W, Dahl J, Snorrason F, Frihagen F, Rohrl S, Madsen JE, Nordsletten L. Radiostereometric analysis of hemiarthroplasties of the hip--a highly precise method for measurements of cartilage wear. Osteoarthritis Cartilage. 2012 Jan;20(1):36-42. doi: 10.1016/j.joca.2011.11.006. Epub 2011 Nov 15.
Results Reference
background
PubMed Identifier
23140091
Citation
Pijls BG, Valstar ER, Nouta KA, Plevier JW, Fiocco M, Middeldorp S, Nelissen RG. Early migration of tibial components is associated with late revision: a systematic review and meta-analysis of 21,000 knee arthroplasties. Acta Orthop. 2012 Dec;83(6):614-24. doi: 10.3109/17453674.2012.747052. Epub 2012 Nov 9.
Results Reference
background
PubMed Identifier
23540721
Citation
van Ijsseldijk EA, Lebel B, Stoel BC, Valstar ER, Gouzy S, Vielpeau C, Kaptein BL. Validation of the in vivo volumetric wear measurement for total knee prostheses in model-based RSA. J Biomech. 2013 Apr 26;46(7):1387-91. doi: 10.1016/j.jbiomech.2013.02.021. Epub 2013 Mar 26.
Results Reference
background
Learn more about this trial
Stability of Contemporary Knee Arthroplasty
We'll reach out to this number within 24 hrs