Part 1 Cohort A: Number of Participants With Non-serious Adverse Events (NSAEs) and Serious Adverse Events (SAEs) in CCI15106
An AE is any untoward medical occurrence in a clinical study participant, temporally associated with the use of a study treatment, whether or not considered related to the study treatment. An SAE is defined as any untoward medical occurrence that, at any dose: results in death, is life-threatening, requires hospitalization or prolongation of existing hospitalization, results in disability/incapacity, is a congenital anomaly/birth defect, other situations judged by physician. Safety population comprised of all participants who received at least one dose of study treatment during the study.
Part 1 Cohort B: Number of Participants With NSAEs and SAEs in CCI15106
An AE is any untoward medical occurrence in a clinical study participant, temporally associated with the use of a study treatment, whether or not considered related to the study treatment. An SAE is defined as any untoward medical occurrence that, at any dose: results in death, is life-threatening, requires hospitalization or prolongation of existing hospitalization, results in disability/incapacity, is a congenital anomaly/birth defect, other situations judged by physician.
Part 1 Cohort C: Number of Participants With NSAEs and SAEs in Bystanders
An AE is any untoward medical occurrence in a clinical study participant, temporally associated with the use of a study treatment, whether or not considered related to the study treatment. An SAE is defined as any untoward medical occurrence that, at any dose: results in death, is life-threatening, requires hospitalization or prolongation of existing hospitalization, results in disability/incapacity, is a congenital anomaly/birth defect, other situations judged by physician.
Part 2 Cohort A: Number of Participants With NSAEs and SAEs
An AE is any untoward medical occurrence in a clinical study participant, temporally associated with the use of a study treatment, whether or not considered related to the study treatment. An SAE is defined as any untoward medical occurrence that, at any dose: results in death, is life-threatening, requires hospitalization or prolongation of existing hospitalization, results in disability/incapacity, is a congenital anomaly/birth defect, other situations judged by physician.
Part 2 Cohort B: Number of Participants With NSAEs and SAEs
An AE is any untoward medical occurrence in a clinical study participant, temporally associated with the use of a study treatment, whether or not considered related to the study treatment. An SAE is defined as any untoward medical occurrence that, at any dose: results in death, is life-threatening, requires hospitalization or prolongation of existing hospitalization, results in disability/incapacity, is a congenital anomaly/birth defect, other situations judged by physician.
Part 1: Number of Participants With Hematology Values of Potential Clinical Importance (PCI) in CCI15106
PCI ranges for the hematology parameters were as follows: hematocrit (high: >0.54 proportion of red blood cell [RBC] in blood for male, >0.54 proportion of RBC in blood for female), hemoglobin (high: >180 grams [g]/L in male, >180 g/L in female), lymphocytes (low: <0.8 10^9/L), neutrophil count (low: <1.5 10^9/L) and platelet count (low: <100 10^9/L and high: 550 10^9/L). Data for the participants with high and low values has been reported.
Part 1: Number of Participants With Hematology Values of PCI in Bystanders
PCI ranges for the hematology parameters were as follows: hematocrit (high: >0.54 proportion of RBC in blood for male, >0.54 proportion of RBC in blood for female), hemoglobin (high: >180 g/L in male, >180 g/L in female), lymphocytes (low: <0.8 10^9/L), neutrophil count (low: <1.5 10^9/L) and platelet count (low: <100 10^9/L and high: 550 10^9/L). Data for the participants with high and low values has been reported.
Part 2: Number of Participants With Hematology Values of PCI
PCI ranges for the hematology parameters were as follows: hematocrit (high: >0.54 proportion of RBC in blood for male, >0.54 proportion of RBC in blood for female), hemoglobin (high: >180 g/L in male, >180 g/L in female), lymphocytes (low: <0.8 10^9/L), neutrophil count (low: <1.5 10^9/L) and platelet count (low: <100 10^9/L and high: 550 10^9/L). Data for the participants with high and low values has been reported.
Part 1: Number of Participants With Clinical Chemistry Values of PCI in CCI15106
PCI ranges for the clinical chemistry parameters were as follows: albumin (low: <30 millimole per liter [mmol/L]), calcium (low: <2 mmol/L and high: >2.75 mmol/L), glucose (low: <3 mmol/L and high: >9 mmol/L), potassium (low: <3 mmol/L and high: >5.5 mmol/L) and sodium (low: <130 mmol/L and high: >150 mmol/L). Data for the participants with high and low values has been reported.
Part 1: Number of Participants With Clinical Chemistry Values of PCI in Bystanders
PCI ranges for the clinical chemistry parameters were as follows: albumin (low: <30 mmol/L), calcium (low: <2 mmol/L and high: >2.75 mmol/L), glucose (low: <3 mmol/L and high: >9 mmol/L), potassium (low: <3 mmol/L and high: >5.5 mmol/L) and sodium (low: <130 mmol/L and high: >150 mmol/L). Data for the participants with high and low values has been reported.
Part 2: Number of Participants With Clinical Chemistry Values of PCI
PCI ranges for the clinical chemistry parameters were as follows: albumin (low: <30 mmol/L), calcium (low: <2 mmol/L and high: >2.75 mmol/L), glucose (low: <3 mmol/L and high: >9 mmol/L), potassium (low: <3 mmol/L and high: >5.5 mmol/L) and sodium (low: <130 mmol/L and high: >150 mmol/L). Data for the participants with high and low values has been reported.
Part 1 Cohort A: Potential of Hydrogen (pH) Value by Visit- CCI15106 60 mg SD
Urine samples were collected from participants at indicated time points for analysis of pH. Baseline was considered as the latest pre-dose assessment with a non-missing value for Baseline (Day -1).
Part 1 Cohort A: pH Value by Visit- CCI15106 120 mg SD
Urine sample was collected from participants at indicated time point for analysis of pH.
Part 1 Cohort A: pH Value by Visit- CCI15106 30 mg BID
Urine samples were collected from participants at indicated time points for analysis of pH.
Part 1 Cohort B: pH Value by Visit- CCI15106 60 mg BID
Urine samples were collected from participants at indicated time points for analysis of pH. Baseline was considered as the latest pre-dose assessment with a non-missing value for Baseline (Day -1).
Part 1: pH Value by Visit- Placebo
Urine samples were collected from participants at indicated time points for analysis of pH. Baseline was considered as the latest pre-dose assessment with a non-missing value for Baseline (Day -1).
Part 1 Cohort C: pH Value by Visit- CCI15106 in Bystanders
Urine samples were collected from participants at indicated time points for analysis of pH. Baseline was considered as the latest pre-dose assessment with a non-missing value for Baseline (Day -1).
Part 2 Cohort A: pH Value by Visit- CCI15106
Urine samples were collected from participants at indicated time points for analysis of pH. Baseline was considered as the latest pre-dose assessment with a non-missing value for Baseline (Day -1).
Part 2 Cohort B: pH Value by Visit- CCI15106 60 mg BID
Urine samples were collected from participants at indicated time points for analysis of pH. Baseline was considered as the latest pre-dose assessment with a non-missing value for Baseline (Day -1).
Part 1 Cohort A: Specific Gravity Value by Visit- CCI15106 60 mg SD
Urinary specific gravity measurement is a routine part of urinalysis. Urine specific gravity is a measure of the concentration of solutes in the urine and provides information on the kidney's ability to concentrate urine. The concentration of the excreted molecules determines the urine's specific gravity. Urine samples were collected from participants at indicated time points for analysis of specific gravity. Baseline was considered as the latest pre-dose assessment with a non-missing value for Baseline (Day -1).
Part 1 Cohort A: Specific Gravity Value by Visit- CCI15106 120 mg SD
Urinary specific gravity measurement is a routine part of urinalysis. Urine specific gravity is a measure of the concentration of solutes in the urine and provides information on the kidney's ability to concentrate urine. The concentration of the excreted molecules determines the urine's specific gravity. Urine sample was collected from participants at indicated time point for analysis of specific gravity.
Part 1 Cohort A: Specific Gravity Value by Visit- CCI15106 30 mg BID
Urinary specific gravity measurement is a routine part of urinalysis. Urine specific gravity is a measure of the concentration of solutes in the urine and provides information on the kidney's ability to concentrate urine. The concentration of the excreted molecules determines the urine's specific gravity. Urine samples were collected from participants at indicated time points for analysis of specific gravity.
Part 1 Cohort B: Specific Gravity Value by Visit- CCI15106 60 mg BID
Urinary specific gravity measurement is a routine part of urinalysis. Urine specific gravity is a measure of the concentration of solutes in the urine and provides information on the kidney's ability to concentrate urine. The concentration of the excreted molecules determines the urine's specific gravity. Urine samples were collected from participants at indicated time points for analysis of Specific gravity. Baseline was considered as the latest pre-dose assessment with a non-missing value for Baseline (Day -1).
Part 1: Specific Gravity Value by Visit- Placebo
Urinary specific gravity measurement is a routine part of urinalysis. Urine specific gravity is a measure of the concentration of solutes in the urine and provides information on the kidney's ability to concentrate urine. The concentration of the excreted molecules determines the urine's specific gravity. Urine samples were collected from participants at indicated time points for analysis of Specific gravity. Baseline was considered as the latest pre-dose assessment with a non-missing value for Baseline (Day -1).
Part 1 Cohort C: Specific Gravity Value by Visit- CCI15106 in Bystanders
Urinary specific gravity measurement is a routine part of urinalysis. Urine specific gravity is a measure of the concentration of solutes in the urine and provides information on the kidney's ability to concentrate urine. The concentration of the excreted molecules determines the urine's specific gravity. Urine samples were collected from participants at indicated time points for analysis of specific gravity. Baseline was considered as the latest pre-dose assessment with a non-missing value for Baseline (Day -1).
Part 2 Cohort A: Specific Gravity Value by Visit- CCI15106
Urinary specific gravity measurement is a routine part of urinalysis. Urine specific gravity is a measure of the concentration of solutes in the urine and provides information on the kidney's ability to concentrate urine. The concentration of the excreted molecules determines the urine's specific gravity. Urine samples were collected from participants at indicated time points for analysis of specific gravity. Baseline was considered as the latest pre-dose assessment with a non-missing value for Baseline (Day -1).
Part 2 Cohort B: Specific Gravity Value by Visit- CCI15106 60 mg BID
Urinary specific gravity measurement is a routine part of urinalysis. Urine specific gravity is a measure of the concentration of solutes in the urine and provides information on the kidney's ability to concentrate urine. The concentration of the excreted molecules determines the urine's specific gravity. Urine samples were collected from participants at indicated time points for analysis of specific gravity. Baseline was considered as the latest pre-dose assessment with a non-missing value for Baseline (Day -1).
Part 1: Number of Participants With Worst Case Post-Baseline 12-lead Electrocardiogram (ECG) of PCI in CCI15106
PCI ranges for the ECG parameters were as follows: absolute QTc interval >450 and <480, >=480 and <500, >=500 milliseconds (msec), absolute PR interval <110 and >220 msec and absolute QRS interval <75 and >110 msec. QTcF=Frederica's QT interval corrected for heart rate; QTcB=Bazett's QT interval corrected for heart rate. Data for worst case post-Baseline has been reported.
Part 1: Number of Participants With Worst Case Post-Baseline 12-lead ECG of PCI in Bystander
PCI ranges for the ECG parameters were as follows: absolute QTc interval >450 and <480, >=480 and <500, >=500 msec, absolute PR interval <110 and >220 msec and absolute QRS interval <75 and >110 msec. Data for worst case post-Baseline has been reported.
Part 2: Number of Participants With Worst Case Post-Baseline 12-lead ECG of PCI
PCI ranges for the ECG parameters were as follows: absolute QTc interval >450 and <480, >=480 and <500, >=500 msec, absolute PR interval <110 and >220 msec and absolute QRS interval <75 and >110 msec. Data for worst case post-Baseline has been reported.
Part 1: Number of Participants With Abnormal Telemetry Findings
Continuous cardiac telemetry was performed from approximately 0.5 hour (pre-dose) to 4 hours post-dose. Abnormal findings were categorized as clinically significant (CS) and not clinically significant (NCS). Clinically significant abnormal findings are those which are not associated with the underlying disease, unless judged by the investigator to be more severe than expected for the participant's condition.
Part 2: Number of Participants With Abnormal Telemetry Findings
Continuous cardiac telemetry was performed from approximately 0.5 hour (pre-dose) to 4 hours post-dose. Abnormal findings were categorized as CS and NCS. Clinically significant abnormal findings are those which are not associated with the underlying disease, unless judged by the investigator to be more severe than expected for the participant's condition.
Part 1: Percent Predicted Forced Expiratory Volume in 1 Second (FEV1) at Indicated Time Points
FEV1 is a measure of lung function and the maximal amount of air that can be forcefully exhaled in one second. FEV1 was measured using standard spirometry. Percent predicted FEV1 was calculated as: Percent predicted FEV1=(maximum FEV1 divided by predicted normal FEV1)*100.
Part 1: Percent Predicted Forced Vital Capacity (FVC) at Indicated Time Points
FVC is a measure of lung function and the maximal amount of air that can be forcefully exhaled in one second. FVC was measured using standard spirometry. Percent predicted FVC was calculated as: Percent predicted FVC=(maximum FVC divided by predicted normal FVC)*100.
Part 2: Percent Predicted FEV1 at Indicated Time Points
FEV1 is a measure of lung function and the maximal amount of air that can be forcefully exhaled in one second. FEV1 was measured using standard spirometry. Percent predicted FEV1 was calculated as: Percent predicted FEV1=(maximum FEV1 divided by predicted normal FEV1)*100.
Part 2: Percent Predicted FVC at Indicated Time Points
FVC is a measure of lung function and the maximal amount of air that can be forcefully exhaled in one second. FVC was measured using standard spirometry. Percent predicted FVC was calculated as: Percent predicted FVC=(maximum FVC divided by predicted normal FVC)*100.
Part 1: Number of Participants With Vital Signs Values of PCI
PCI ranges for the vital signs parameters were as follows: systolic blood pressure (SBP) <85 and >160 millimeters of mercury (mmHg), diastolic blood pressure (DBP) <45 and >100 mmHg and heart rate <40 and >110 beats per minute (bpm). Data for the participants with high and low values has been reported.
Part 1: Number of Participants With Vital Signs Values of PCI in Bystanders
PCI ranges for the vital signs parameters were as follows: SBP <85 and >160 mmHg, DBP <45 and >100 mmHg and heart rate <40 and >110 bpm. Data for the participants with high and low values has been reported.
Part 2: Number of Participants With Vital Signs Values of PCI
PCI ranges for the vital signs parameters were as follows: SBP <85 and >160 mmHg, DBP <45 and >100 mmHg and heart rate <40 and >110 bpm. Data for the participants with high and low values has been reported.
Part 1 Cohort A: Area Under the Curve (AUC) From Time Zero to the Time of Last Quantifiable Concentration (AUC[0-t]) After Single Dose Administration of CCI15106 60 mg on Day 1
Blood samples were collected to evaluate the pharmacokinetics (PKs) of CCI15106 at the indicated time points on Day 1 for the analysis of AUC(0-t) data. PK population consisted of participants who received at least one dose of study treatment and who undergo plasma PK sampling and had at least one post-dose concentration result.
Part 1 Cohort A: AUC(0-t) After Single Dose Administration of CCI15106 120 mg on Day 3
Blood samples were collected to evaluate the PKs of CCI15106 at the indicated time points on Day 3 for the analysis of AUC(0-t) data.
Part 2 Cohort A: AUC(0-t) After Single Dose Administration of CCI15106 60 mg on Day 1
Blood samples were collected to evaluate the PKs of CCI15106 at the indicated time points on Day 1 for the analysis of AUC(0-t) data.
Part 1 Cohort A: Maximum Observed Plasma Concentration (Cmax) After Single Dose Administration of CCI15106 60 mg on Day 1
Blood samples were collected to evaluate the PKs of CCI15106 at the indicated time points on Day 1 for the analysis of Cmax data.
Part 1 Cohort A: Cmax After Single Dose Administration of CCI15106 120 mg on Day 3
Blood samples were collected to evaluate the PKs of CCI15106 at the indicated time points on Day 3 for the analysis of Cmax data.
Part 2 Cohort A: Cmax After Single Dose Administration of CCI15106 60 mg on Day 1
Blood samples were collected to evaluate the PKs of CCI15106 at the indicated time points on Day 1 for the analysis of Cmax data.
Part 1 Cohort A: Time of Maximum Concentration (Tmax) After Single Dose Administration of CCI15106 60 mg on Day 1
Blood samples were collected to evaluate the PKs of CCI15106 at the indicated time points on Day 1 for the analysis of tmax data.
Part 1 Cohort A: Tmax After Single Dose Administration of CCI15106 120 mg on Day 3
Blood samples were collected to evaluate the PKs of CCI15106 at the indicated time points on Day 3 for the analysis of tmax data.
Part 2 Cohort A: Tmax After Single Dose Administration of CCI15106 60 mg on Day 1
Blood samples were collected to evaluate the PKs of CCI15106 at the indicated time points on Day 1 for the analysis of tmax data.
Part 1 Cohort A: AUC From Time Zero to Infinity (AUC[0-infinity]) After Single Dose Administration of CCI15106 60 mg on Day 1
Blood samples were collected to evaluate the PKs of CCI15106 at the indicated time points on Day 1 for the analysis of AUC(0-infinity) data.
Part 1 Cohort A: AUC(0-infinity) After Single Dose Administration of CCI15106 120 mg on Day 3
Blood samples were collected to evaluate the PKs of CCI15106 at the indicated time points on Day 3 for the analysis of AUC(0-infinity) data.
Part 2 Cohort A: AUC(0-infinity) After Single Dose Administration of CCI15106 60 mg on Day 1
Blood samples were collected to evaluate the PKs of CCI15106 at the indicated time points on Day 1 for the analysis of AUC(0-infinity) data.
Part 1 Cohort A: Elimination Half-life (t1/2) After Single Dose Administration of CCI15106 60 mg on Day 1
Blood samples were collected to evaluate the PKs of CCI15106 at the indicated time points on Day 1 for the analysis of t1/2 data.
Part 1 Cohort A: t1/2 After Single Dose Administration of CCI15106 120 mg on Day 3
Blood samples were collected to evaluate the PKs of CCI15106 at the indicated time points on Day 3 for the analysis of t1/2 data.
Part 2 Cohort A: t1/2 After Single Dose Administration of CCI15106 60 mg on Day 1
Blood samples were collected to evaluate the PKs of CCI15106 at the indicated time points on Day 1 for the analysis of t1/2 data.
Part 1 Cohort A: Clearance (CL/F) After Single Dose Administration of CCI15106 60 mg on Day 1
Blood samples were collected to evaluate the PKs of CCI15106 at the indicated time points on Day 1 for the analysis of CL/F data.
Part 1 Cohort A: CL/F After Single Dose Administration of CCI15106 120 mg on Day 3
Blood samples were collected to evaluate the PKs of CCI15106 at the indicated time points on Day 3 for the analysis of CL/F data.
Part 2 Cohort A: CL/F After Single Dose Administration of CCI15106 60 mg on Day 1
Blood samples were collected to evaluate the PKs of CCI15106 at the indicated time points on Day 1 for the analysis of CL/F data.
Part 1 Cohort A: AUC From Time Zero to End of Dosing Interval (AUC[0-tau]) After Repeated Dose Administration of CCI15106 30 mg
Blood samples were collected to evaluate the PKs of CCI15106 at the indicated time points on Days 6 and 19 for the analysis of AUC(0-tau) data.
Part 1 Cohort B: AUC(0-tau) After Repeated Dose Administration of CCI15106 60 mg
Blood samples were collected to evaluate the PKs of CCI15106 at the indicated time points on Days 1 and 14 for the analysis of AUC(0-tau) data.
Part 2 Cohort B: AUC(0-tau) After Repeated Dose Administration of CCI15106 60 mg
Blood samples were collected to evaluate the PKs of CCI15106 at the indicated time points on Days 1 and 14 for the analysis of AUC(0-tau) data.
Part 1 Cohort A: Cmax After Repeated Dose Administration of CCI15106 30 mg
Blood samples were collected to evaluate the PKs of CCI15106 at the indicated time points on Days 6 and 19 for the analysis of Cmax data.
Part 1 Cohort B: Cmax After Repeated Dose Administration of CCI15106 60 mg
Blood samples were collected to evaluate the PKs of CCI15106 at the indicated time points on Days 1 and 14 for the analysis of Cmax data.
Part 2 Cohort B: Cmax After Repeated Dose Administration of CCI15106 60 mg
Blood samples were collected to evaluate the PKs of CCI15106 at the indicated time points on Days 1 and 14 for the analysis of Cmax data.
Part 1 Cohort A: Tmax After Repeated Dose Administration of CCI15106 30 mg
Blood samples were collected to evaluate the PKs of CCI15106 at the indicated time points on Days 6 and 19 for the analysis of tmax data.
Part 1 Cohort B: Tmax After Repeated Dose Administration of CCI15106 60 mg
Blood samples were collected to evaluate the PKs of CCI15106 at the indicated time points on Days 1 and 14 for the analysis of tmax data.
Part 2 Cohort B: Tmax After Repeated Dose Administration of CCI15106 60 mg
Blood samples were collected to evaluate the PKs of CCI15106 at the indicated time points on Days 1 and 14 for the analysis of tmax data.
Part 1 Cohort A: t1/2 After Repeated Dose Administration of CCI15106 30 mg
Blood samples were collected to evaluate the PKs of CCI15106 at the indicated time points on Days 6 and 19 for the analysis of t1/2 data.
Part 1 Cohort B: t1/2 After Repeated Dose Administration of CCI15106 60 mg
Blood samples were collected to evaluate the PKs of CCI15106 at the indicated time points on Days 1 and 14 for the analysis of t1/2 data.
Part 2 Cohort B: t1/2 After Repeated Dose Administration of CCI15106 60 mg
Blood samples were collected to evaluate the PKs of CCI15106 at the indicated time points on Days 1 and 14 for the analysis of t1/2 data.
Part 1: Concentration of CCI15106 in Plasma of Bystanders: Cohort C
Blood samples were collected from bystanders 15 minutes after dosing at indicated time points. Bystander PK population consisted of participants who were present at least once in the room with the participant receiving the dose, undergo plasma PK sampling and had post-dose concentration result.
Part 1: Concentration of CCI15106 Accumulated on Filters Fitted on Bystander: Cohort C
Personal exposure air samples were collected on filters placed on each bystander after the first daily dose at indicated time points. The filters were used to measure CCI15106 concentration in the person's breathing zone. Fixed location concentrations were measured near window, near door, back to wall and facing wall in the dosing room over 15 minutes post-dose. Each bystander had a filter attached to their study clothing. The filters were measured for CCI15106. This was a single measurement from the filter for each bystsander. The locations (near window, near door, back to wall and facing wall) were just to record where the bystander was located in the room.
Part 1: Concentration of CCI15106 Accumulated on Filters Fitted on Stationary Pumps: Cohort C
Static air samples were collected on filters within air pumps positioned in two locations (bench and corner) in the room. Sampling devices attached to sampling pumps were used to measure CCI15106 concentration. Fixed location concentrations were measured in corner of room and on bench at back of room over 20 minutes and 60 minutes post-dosing.