Study of Techniques of Subcutaneous Administration of Fluids Enabled by Human Recombinant Hyaluronidase (INFUSE-AT)
Dehydration
About this trial
This is an interventional treatment trial for Dehydration focused on measuring dehydration, fluid therapy, hyaluronoglucosaminidase, hyaluronidase, hypodermoclysis, clysis, subcutaneous hydration, subcutaneous rehydration, hyaluronan, rHuPH20
Eligibility Criteria
Inclusion Criteria:
- male or female, aged 18 to 60 years
- intact normal skin without potentially obscuring features on both anterior thighs in the area intended for infusion
- agreeing to no fluid intake for 12 hours prior to start of study infusion
- vital signs within normal range or, if outside normal range, deemed not clinically significant
- metabolic panel, hematology, virology and standard 10-test urine dipstick tests within normal range, or if outside normal range, deemed not clinically significant
- if female of child-bearing potential,negative serum pregnancy tests
- negative urine drug screens
- written informed consent for participation
Exclusion Criteria:
- lower extremity edema
- lower extremity pathology that could interfere with study outcome
- history of cardiovascular disease
- rales on lung auscultation
- known allergy to hyaluronidase or other ingredient in the formulation of hylenex
- pregnancy or breast-feeding a child
- exposure to any experimental drug within 30 days prior to study participation
- previous participation in this study
Sites / Locations
- MDS Pharma Services
- MDS Pharma Services
Arms of the Study
Arm 1
Arm 2
Arm 3
Arm 4
Arm 5
Arm 6
Arm 7
Arm 8
Arm 9
Experimental
Experimental
Experimental
Experimental
Experimental
Experimental
Experimental
Experimental
Experimental
Tegaderm-secured 24 ga Teflon catheter
Tape-secured 24 ga Teflon catheter
Tegaderm-secured 24 ga polyurethane catheter
Tape-secured 24 ga polyurethane catheter
Tegaderm-secured 20 ga Teflon catheter
Tape-secured 20 ga Teflon catheter
Tegaderm-secured 20 ga polyurethane catheter
Tape-secured 20 ga polyurethane catheter
SC button with 27 ga X 9 mm needle
subcutaneous administration of a single 150 U dose of hylenex, followed by subcutaneous infusion (delivered by large volume infusion pump) of 1000 mL Lactated Ringer's solution, both delivered through a 24-gauge, 0.75 inch long, Teflon angiocatheter secured with Tegaderm
subcutaneous administration of a single 150 U dose of hylenex, followed by subcutaneous infusion (delivered by large volume infusion pump) of 1000 mL Lactated Ringer's solution, both delivered through a 24-gauge, 0.75 inch long, Teflon angiocatheter secured with a tape double chevron
subcutaneous administration of a single 150 U dose of hylenex, followed by subcutaneous infusion (delivered by large volume infusion pump) of 1000 mL Lactated Ringer's solution, both delivered through a 24-gauge, 0.75 inch long, polyurethane angiocatheter secured with Tegaderm
subcutaneous administration of a single 150 U dose of hylenex, followed by subcutaneous infusion (delivered by large volume infusion pump) of 1000 mL Lactated Ringer's solution, both delivered through a 24-gauge, 0.75 inch long, polyurethane angiocatheter secured with a tape double chevron
subcutaneous administration of a single 150 U dose of hylenex, followed by subcutaneous infusion (delivered by large volume infusion pump) of 1000 mL Lactated Ringer's solution, both delivered through a 20-gauge, 1.0 inch long, Teflon angiocatheter secured with Tegaderm
subcutaneous administration of a single 150 U dose of hylenex, followed by subcutaneous infusion (delivered by large volume infusion pump) of 1000 mL Lactated Ringer's solution, both delivered through a 20-gauge, 1.0 inch long, Teflon angiocatheter secured with a tape double chevron
subcutaneous administration of a single 150 U dose of hylenex, followed by subcutaneous infusion (delivered by large volume infusion pump) of 1000 mL Lactated Ringer's solution, both delivered through a 20-gauge, 1.0 inch long, polyurethane angiocatheter secured with Tegaderm
subcutaneous administration of a single 150 U dose of hylenex, followed by subcutaneous infusion (delivered by large volume infusion pump) of 1000 mL Lactated Ringer's solution, both delivered through a 20-gauge, 1.0 inch long, polyurethane angiocatheter secured with a tape double chevron
subcutaneous administration of a single 150 U dose of hylenex, followed by subcutaneous infusion (delivered by large volume infusion pump) of 1000 mL Lactated Ringer's solution, both delivered through a button-type subcutaneous delivery system (with a 27-gauge, 9 mm long metal needle)