The Accuracy of the Mini RELF Device for the Diagnosis of an Acute Coronary Artery Occlusion. (RELF IIa)

Primary Purpose

Chest Pain, ST Elevation Myocardial Infarction

Status
Completed
Phase
Not Applicable
Locations
Belgium
Study Type
Interventional
Intervention
Diagnostic accuracy of Mini Relf Device
Sponsored by
University Ghent
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional diagnostic trial for Chest Pain focused on measuring RELF method, Medical device, Admission delay

Eligibility Criteria

undefined - undefined (Child, Adult, Older Adult)All SexesDoes not accept healthy volunteers

Inclusion Criteria:

  • Patients who have an appointment for an elective coronary angioplasty.

Exclusion Criteria:

  • Patients with coronary artery bypass grafts.
  • Patients with implanted pacemaker or ICD.
  • Patients who remain hospitalized until the planned angioplasty.
  • Patient who are unfamiliar with use of smart phone. The test question "did you use by yourself a smart phone to make a telephone call in the last 4 weeks" should be answered by yes.
  • Patients who cannot tolerate repetitive applications of standard skin electrodes on the chest.

Sites / Locations

  • Algemeen Ziekenhuis Sint-Jan Brugge
  • University Hospital Ghent
  • AZ Sint Nikolaas

Arms of the Study

Arm 1

Arm Type

Experimental

Arm Label

no transmural ischemia (NTI) and transmural ischemia (TI)

Arm Description

Case cross-over from "no transmural ischemia (NTI)" to "transmural ischemia at 60 s coronary occlusion during elective coronary angioplasty (TI)" Comparison of diagnostic accuracy of standard 12-lead ECG versus Mini RELF device for detection of transmural ischemia.

Outcomes

Primary Outcome Measures

The accuracy (Area under the sensitivity-aspecificity curve) of Modus RELF-2 (The orthonormalized ST shift vector magnitude)
The sensitivity and specificity of the orthonormalized ST shift vector magnitude during occlusion compared to the sensitivity and specificity of the 12 lead ECG.

Secondary Outcome Measures

The accuracy (Area under the sensitivity-aspecificity curve) of Modus RELF-3
The sensitivity and specificity of the intraindividual orthonormalized ST shift vector magnitude
The accuracy (Area under the sensitivity-aspecificity curve) of Modus RELF-1 (The gender specific orthonormalized ST vector magnitude) and of Modus RELF-3 (The intra-individual orthonormalized ST shift vector magnitude).
The sensitivity and specificity of the gender specific orthonormalized ST vector magnitude and the intra-individual orthonormalized ST shift vector magnitude during occlusion compared to the sensitivity and specificity of the 12 lead ECG.
Number of participants with symptoms of contact dermatitis in the thoracic device-skin contact area.
Contact dermatitis is defined by the clinical presence of redness or itching or blistering delineated in the thoracic device-skin contact area during at least one of the three clinical visits in the study participation period.

Full Information

First Posted
October 25, 2016
Last Updated
December 2, 2021
Sponsor
University Ghent
search

1. Study Identification

Unique Protocol Identification Number
NCT02983396
Brief Title
The Accuracy of the Mini RELF Device for the Diagnosis of an Acute Coronary Artery Occlusion.
Acronym
RELF IIa
Official Title
The Accuracy of the Mini RELF Device Relative to the 12 Lead ECG for the Diagnosis of an Acute Coronary Artery Occlusion in Patients With Coronary Artery Disease.
Study Type
Interventional

2. Study Status

Record Verification Date
December 2021
Overall Recruitment Status
Completed
Study Start Date
November 18, 2016 (Actual)
Primary Completion Date
April 19, 2018 (Actual)
Study Completion Date
April 19, 2018 (Actual)

3. Sponsor/Collaborators

Responsible Party, by Official Title
Sponsor
Name of the Sponsor
University Ghent

4. Oversight

Data Monitoring Committee
Yes

5. Study Description

Brief Summary
Patient delay in seeking medical attendance for symptoms of acute ST elevation myocardial infarction (STEMI) is the major obstacle to reduce the current mortality from acute coronary syndromes. The Mini RELF device is a hand held self applicable device intended to detect on an individual basis an elevation of the ST segment that is indicative for an acute coronary occlusion. The investigators aim to evaluate the accuracy of Mini RELF device when it is self-applied on a daily basis by patients with coronary artery disease.
Detailed Description
The increasing availability of small hand held medical devices is a novel opportunity to develop a tool that guides patients through the decision-taking processes of seeking medical attendance during symptoms suggestive of acute myocardial infarction. The cornerstone of early diagnosis, risk stratification and treatment is the presence of ST segment elevation during symptoms suggestive of STEMI. Therefore, a hand held medical device that can detect ST segment elevation with high sensitivity and specificity could be a breakthrough in the further reduction of fatality from acute myocardial infarction. A number of conditions of the tool must be fulfilled to allow save use with a low threshold in the general population. Most important is the accuracy to detect any new ST segment elevation related to an acute artery occlusion. For more than 30 years the 12-lead ECG is the gold standard for detection of ST elevation. However, acute coronary occlusions of a posterior or lateral segment are not always detected by the gold standard. Moreover, in the very early phase of acute coronary occlusion, the accuracy 12 lead ECG is inadequate. In a previous study "Diagnostic accuracy of a novel method for detection of acute transmural myocardial ischemia based upon a self-applicable 3-lead configuration" the investigators developed and validated a sensitive and specific 3-lead ECG method (RELF method). The method includes a new lead configuration and a new algorithm to analyze the ECG recordings based on an intra-individual comparisons of ST levels. In summary, a 3-lead recording from a healthy subject or from a patient with an acute coronary occlusion is compared automatically to one or more previous reference recordings from the same individual. The individualized ST shift is used as a decision variable to detect or reject an acute coronary artery occlusion. The RELF method was more accurate then the simultaneously applied 12-lead ECG which had a lower sensitivity and specificity. In that study all recordings were performed by a sophisticated ECG recording system. The RELF method is designed to be applicable also by small hand held ECG devices such as the self-applicable Mini RELF device. In the current study the investigators aim to evaluate the accuracy of Mini RELF device relative to the 12 lead ECG when the device is self-applied on a daily basis by patients with coronary artery disease. In a parallel study (RELF IIb) the investigators aim to evaluate the specificity of the RELF method when it is self-applied by healthy subjects who are representative for future users of the device.

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Chest Pain, ST Elevation Myocardial Infarction
Keywords
RELF method, Medical device, Admission delay

7. Study Design

Primary Purpose
Diagnostic
Study Phase
Not Applicable
Interventional Study Model
Single Group Assignment
Masking
None (Open Label)
Allocation
N/A
Enrollment
64 (Actual)

8. Arms, Groups, and Interventions

Arm Title
no transmural ischemia (NTI) and transmural ischemia (TI)
Arm Type
Experimental
Arm Description
Case cross-over from "no transmural ischemia (NTI)" to "transmural ischemia at 60 s coronary occlusion during elective coronary angioplasty (TI)" Comparison of diagnostic accuracy of standard 12-lead ECG versus Mini RELF device for detection of transmural ischemia.
Intervention Type
Device
Intervention Name(s)
Diagnostic accuracy of Mini Relf Device
Intervention Description
Evaluation of the Mini Relf Device when it is applied on daily basis at home and during coronary angioplasty at 60 second acute coronary occlusion angioplasty
Primary Outcome Measure Information:
Title
The accuracy (Area under the sensitivity-aspecificity curve) of Modus RELF-2 (The orthonormalized ST shift vector magnitude)
Description
The sensitivity and specificity of the orthonormalized ST shift vector magnitude during occlusion compared to the sensitivity and specificity of the 12 lead ECG.
Time Frame
One week after coronary angioplasty
Secondary Outcome Measure Information:
Title
The accuracy (Area under the sensitivity-aspecificity curve) of Modus RELF-3
Description
The sensitivity and specificity of the intraindividual orthonormalized ST shift vector magnitude
Time Frame
One week after coronary angioplasty
Title
The accuracy (Area under the sensitivity-aspecificity curve) of Modus RELF-1 (The gender specific orthonormalized ST vector magnitude) and of Modus RELF-3 (The intra-individual orthonormalized ST shift vector magnitude).
Description
The sensitivity and specificity of the gender specific orthonormalized ST vector magnitude and the intra-individual orthonormalized ST shift vector magnitude during occlusion compared to the sensitivity and specificity of the 12 lead ECG.
Time Frame
One week after coronary angioplasty
Title
Number of participants with symptoms of contact dermatitis in the thoracic device-skin contact area.
Description
Contact dermatitis is defined by the clinical presence of redness or itching or blistering delineated in the thoracic device-skin contact area during at least one of the three clinical visits in the study participation period.
Time Frame
One week after coronary angioplasty

10. Eligibility

Sex
All
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria: Patients who have an appointment for an elective coronary angioplasty. Exclusion Criteria: Patients with coronary artery bypass grafts. Patients with implanted pacemaker or ICD. Patients who remain hospitalized until the planned angioplasty. Patient who are unfamiliar with use of smart phone. The test question "did you use by yourself a smart phone to make a telephone call in the last 4 weeks" should be answered by yes. Patients who cannot tolerate repetitive applications of standard skin electrodes on the chest.
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Peter Gheeraert, Professor
Organizational Affiliation
University Ghent, Belgium
Official's Role
Study Chair
Facility Information:
Facility Name
Algemeen Ziekenhuis Sint-Jan Brugge
City
Brugge
ZIP/Postal Code
8000
Country
Belgium
Facility Name
University Hospital Ghent
City
Ghent
ZIP/Postal Code
9000
Country
Belgium
Facility Name
AZ Sint Nikolaas
City
Sint-Niklaas
ZIP/Postal Code
9100
Country
Belgium

12. IPD Sharing Statement

Plan to Share IPD
No
Citations:
PubMed Identifier
33323233
Citation
Van Heuverswyn F, De Buyzere M, Coeman M, De Pooter J, Drieghe B, Duytschaever M, Gevaert S, Kayaert P, Vandekerckhove Y, Voet J, El Haddad M, Gheeraert P. Feasibility and performance of a device for automatic self-detection of symptomatic acute coronary artery occlusion in outpatients with coronary artery disease: a multicentre observational study. Lancet Digit Health. 2019 Jun;1(2):e90-e99. doi: 10.1016/S2589-7500(19)30026-3. Epub 2019 May 23.
Results Reference
derived

Learn more about this trial

The Accuracy of the Mini RELF Device for the Diagnosis of an Acute Coronary Artery Occlusion.