Vascular function in postoperative arteriovenous fistula
After the participants rested for 5 minutes at the temperature of the ultrasound room set at 25°C, professional radiology technicians used ultrasonic instruments to check and record the inner diameter of the blood vessel and the peak blood flow velocity of the drainage vein of the participant's arteriovenous fistula
Change from Baseline Vascular function in postoperative arteriovenous fistula at two weeks
After the participants rested for 5 minutes at the temperature of the ultrasound room set at 25°C, professional radiology technicians used ultrasonic instruments to check and record the inner diameter of the blood vessel and the peak blood flow velocity of the drainage vein of the participant's arteriovenous fistula
Change from Baseline Vascular function in postoperative arteriovenous fistula at four weeks
After the participants rested for 5 minutes at the temperature of the ultrasound room set at 25°C, professional radiology technicians used ultrasonic instruments to check and record the inner diameter of the blood vessel and the peak blood flow velocity of the drainage vein of the participant's arteriovenous fistula
Change from Baseline Vascular function in postoperative arteriovenous fistula at eight weeks
After the participants rested for 5 minutes at the temperature of the ultrasound room set at 25°C, professional radiology technicians used ultrasonic instruments to check and record the inner diameter of the blood vessel and the peak blood flow velocity of the drainage vein of the participant's arteriovenous fistula
Clinical assessment of arteriovenous fistula maturity
After the participants rested for 5 minutes at the temperature of the ultrasound room set at 25°C, senior hemodialysis nurses assessed whether there were palpable tremors in the blood vessels of the arteriovenous fistula, and whether there were obvious visible veins and arteriovenous in the arteriovenous fistula. Fistula with or without visible vessels >10 cm line.
Change from Baseline Clinical assessment of arteriovenous fistula maturity at four weeks
After the participants rested for 5 minutes at the temperature of the ultrasound room set at 25°C, senior hemodialysis nurses assessed whether there were palpable tremors in the blood vessels of the arteriovenous fistula, and whether there were obvious visible veins and arteriovenous in the arteriovenous fistula. Fistula with or without visible vessels >10 cm line.
Change from Baseline Clinical assessment of arteriovenous fistula maturity at eight weeks
After the participants rested for 5 minutes at the temperature of the ultrasound room set at 25°C, senior hemodialysis nurses assessed whether there were palpable tremors in the blood vessels of the arteriovenous fistula, and whether there were obvious visible veins and arteriovenous in the arteriovenous fistula. Fistula with or without visible vessels >10 cm line.
Ultrasonic evaluation of arteriovenous fistula maturity
After the participants rested for 5 minutes at the temperature of the ultrasound room set at 25°C, the vascular radiologist used the ultrasound equipment of the Philips ClearVue 550 ultrasound system (ClearVue 550, USA) to assess whether the participant's arteriovenous fistula was far from the skin. <6mm, whether the inner diameter of the outflow brachiocephalic vein is >6mm, whether the brachial artery flow rate is >600 mL/min, and record the measured values.
Change from Baseline Ultrasonic evaluation of arteriovenous fistula maturity at four weeks
After the participants rested for 5 minutes at the temperature of the ultrasound room set at 25°C, the vascular radiologist used the ultrasound equipment of the Philips ClearVue 550 ultrasound system (ClearVue 550, USA) to assess whether the participant's arteriovenous fistula was far from the skin. <6mm, whether the inner diameter of the outflow brachiocephalic vein is >6mm, whether the brachial artery flow rate is >600 mL/min, and record the measured values.
Change from Baseline Ultrasonic evaluation of arteriovenous fistula maturity at eight weeks
After the participants rested for 5 minutes at the temperature of the ultrasound room set at 25°C, the vascular radiologist used the ultrasound equipment of the Philips ClearVue 550 ultrasound system (ClearVue 550, USA) to assess whether the participant's arteriovenous fistula was far from the skin. <6mm, whether the inner diameter of the outflow brachiocephalic vein is >6mm, whether the brachial artery flow rate is >600 mL/min, and record the measured values.
Hand Grip Strength
Grip Strength Assessment using a hydraulic hand-held dynamometer (Takei Hand Grip Dynamometer, Japan), the arm muscle strength of the participants in the non-dominant hand was assessed. The participants sits on a chair with a backrest, with the hips bent 90 degrees, feet flat on the ground, shoulders adducted, elbows bent 90 degrees, the non-dominant arm is in a neutral position, the wrist is maintained at an extension angle of 0-30 degrees, and the ulnar side is biased. Move 0~15 degrees. A total of three measurements will be taken with a one-minute rest in between, and measurements were made in kilograms (Kg). In addition, on the 15th day after the operation, the experimental group started to use the smart grip device for forearm isometric exercise and recorded the data after grip strength training.
Change from Baseline Hand Grip Strength at two weeks
Grip Strength Assessment using a hydraulic hand-held dynamometer (Takei Hand Grip Dynamometer, Japan), the arm muscle strength of the participants in the non-dominant hand was assessed. The participants sits on a chair with a backrest, with the hips bent 90 degrees, feet flat on the ground, shoulders adducted, elbows bent 90 degrees, the non-dominant arm is in a neutral position, the wrist is maintained at an extension angle of 0-30 degrees, and the ulnar side is biased. Move 0~15 degrees. A total of three measurements will be taken with a one-minute rest in between, and measurements were made in kilograms (Kg). In addition, on the 15th day after the operation, the experimental group started to use the smart grip device for forearm isometric exercise and recorded the data after grip strength training.
Change from Baseline Hand Grip Strength at four weeks
Grip Strength Assessment using a hydraulic hand-held dynamometer (Takei Hand Grip Dynamometer, Japan), the arm muscle strength of the participants in the non-dominant hand was assessed. The participants sits on a chair with a backrest, with the hips bent 90 degrees, feet flat on the ground, shoulders adducted, elbows bent 90 degrees, the non-dominant arm is in a neutral position, the wrist is maintained at an extension angle of 0-30 degrees, and the ulnar side is biased. Move 0~15 degrees. A total of three measurements will be taken with a one-minute rest in between, and measurements were made in kilograms (Kg). In addition, on the 15th day after the operation, the experimental group started to use the smart grip device for forearm isometric exercise and recorded the data after grip strength training.
Change from Baseline Hand Grip Strength at eight weeks
Grip Strength Assessment using a hydraulic hand-held dynamometer (Takei Hand Grip Dynamometer, Japan), the arm muscle strength of the participants in the non-dominant hand was assessed. The participants sits on a chair with a backrest, with the hips bent 90 degrees, feet flat on the ground, shoulders adducted, elbows bent 90 degrees, the non-dominant arm is in a neutral position, the wrist is maintained at an extension angle of 0-30 degrees, and the ulnar side is biased. Move 0~15 degrees. A total of three measurements will be taken with a one-minute rest in between, and measurements were made in kilograms (Kg). In addition, on the 15th day after the operation, the experimental group started to use the smart grip device for forearm isometric exercise and recorded the data after grip strength training.
Rate of participants' exercise adherence
Participants began to self-register daily exercise times, each exercise group, each exercise frequency, and self-assessed daily exercise effort scores in the exercise log on the second day after the operation, and the end of the 8th week of exercise post-compute rate of adherence.
Change from Baseline Rate of Adherence at four weeks
Participants began to self-register daily exercise times, each exercise group, each exercise frequency, and self-assessed daily exercise effort scores in the exercise log on the second day after the operation, and the end of the 8th week of exercise post-compute rate of adherence.
Change from Baseline Rate of Adherence at eight weeks
Participants began to self-register daily exercise times, each exercise group, each exercise frequency, and self-assessed daily exercise effort scores in the exercise log on the second day after the operation, and the end of the 8th week of exercise post-compute rate of adherence.