The Effectiveness of 4D Image Acquisition and Post-processing With Vios Works
Primary Purpose
Cardiac Disease
Status
Active
Phase
Not Applicable
Locations
United States
Study Type
Interventional
Intervention
Imaging software for 4 dimensional images for Cardiac MRI
Sponsored by
About this trial
This is an interventional diagnostic trial for Cardiac Disease
Eligibility Criteria
Inclusion Criteria:
- 18 years of age or older
- with a valid prescription for Cardiac MRI for the following: Congenital heart disease/Shunts, Valvular heart disease, Pulmonary Hypertension, Aortic Disease, Hypertrophic Cardiomyopathy (HCM)
- receiving Standard of Care services at the MRI Center
- consent to participate in the 4D trial
Exclusion Criteria:
Patients with any of the following will be excluded:
- Pacemaker or ICD implanted
- ICDs implanted
- Temporary Pacemakers (e.g. transvenous temporary wires)
- Leads that are abandoned (capped or retained leads not attached to device)
- Non-transvenous leads (e.g. epicardial leads)
- Leads that have no fixation (e.g. floating leads)
- A lead that is known to be fractured
- Any other metallic objects that, in the opinion of the safety officer would compromise patient safety
Sites / Locations
- Northwell Health Imaging at Greenwich Village: a Division of Lenox Hill Hospital
Arms of the Study
Arm 1
Arm Type
Experimental
Arm Label
All Enrollees
Arm Description
Intervention: Diagnostic test All enrollees will receive a 4D MRI as a research intervention using imaging software for 4 dimensional images for Cardiac MRI
Outcomes
Primary Outcome Measures
2D imaging findings and medical diagnoses resulting from images.
Investigators will count the number of study outcomes documented that are related to patient treatment.
4D imaging findings and medical diagnoses resulting from images.
Investigators will count the number of study outcomes documented that are related to patient treatment.
Secondary Outcome Measures
2D Time to scan acquisition
Investigators will document time to acquire 2D image.
Time to 2D scan interpretation
Time to interpret 2-D scan interpretation will be from the time the reader starts reading the 2D scan until the time the reader finishes reading the 2D scan.
Intra-reader reliability
Each reader will read each scan assigned on two different dates. The reader will be blind to identity of scan. The two readings will be compared for consistency.
Image quality
Overall measure of all scan image quality based on standard quality assessment protocol definitions.
2D patient recommended treatments
The reader will document recommendations for patient treatment based on 2D imaging results
90 day follow up
Describe patient follow-up. The interviewer will record the patient follow up by interviewing the patient within 90 to 120 days of the scan and asking what follow up was taken; and by medical record review. Follow up will be recorded and will be compared to recommended follow up.
4D Time to scan acquisition
Investigators will document time to acquire 4D image
Time to 4D scan interpretation
Time to interpret 4D scan interpretation will be from the time the reader starts reading the 4D scan until the time the reader finishes reading the 4D scan.
Inter-reader reliability
Two readers will read each scan. The readers will be blind to identity of scan. the reader will not know the results reported by the second reader. The two readings will be compared for consistency.
4D patient recommended treatments
The reader will document recommendations for patient treatment based on 4D imaging results
Full Information
NCT ID
NCT03128268
First Posted
April 3, 2017
Last Updated
October 25, 2022
Sponsor
Northwell Health
Collaborators
GE Healthcare, Arterys, Inc.
1. Study Identification
Unique Protocol Identification Number
NCT03128268
Brief Title
The Effectiveness of 4D Image Acquisition and Post-processing With Vios Works
Official Title
THE EFFECTIVENESS OF 4D IMAGE ACQUISITION AND POST-PROCESSING WITH VIOS WORKS: A Phase Design Prospective Clinical Trial to Assess 4D Software Produced by GE and Arterys for Evaluating Cardiac Disease.
Study Type
Interventional
2. Study Status
Record Verification Date
October 2022
Overall Recruitment Status
Active, not recruiting
Study Start Date
February 20, 2018 (Actual)
Primary Completion Date
April 26, 2021 (Actual)
Study Completion Date
June 20, 2023 (Anticipated)
3. Sponsor/Collaborators
Responsible Party, by Official Title
Principal Investigator
Name of the Sponsor
Northwell Health
Collaborators
GE Healthcare, Arterys, Inc.
4. Oversight
Studies a U.S. FDA-regulated Drug Product
No
Studies a U.S. FDA-regulated Device Product
Yes
Device Product Not Approved or Cleared by U.S. FDA
Yes
Product Manufactured in and Exported from the U.S.
No
Data Monitoring Committee
No
5. Study Description
Brief Summary
This study aims to evaluate the effectiveness of 4D image acquisition and post-processing with Vios Works for the evaluation of 3D images acquired on GE Magnetic Resonance Imaging scanners. Specifically, the investigators propose to evaluate the following:
Image acquisition time using traditional 2D and new 4D processing techniques;
Image quality for 2D and 4D processing techniques subjectively
Post-processing time for the two techniques.
Correlation of overall Left ventricular and right ventricular volumes and functions and aortic and pulmonic flow studies using the two techniques.
The study will monitor any changes in patient diagnoses or treatment resulting from any differences in interpretations between the two processes.
Detailed Description
Traditional scanning and post-processing of 2D Cardiac Magnetic Resonance images (CMRI) is highly technical and time consuming, with many exams requiring one to two hours to complete. In addition, performance of 2D scans often requires expert technologists working closely with the clinician imaging expert. These factors limit the general clinical utility of current generation cardiac MRI.
In order to address these factors, many researchers began to explore the use of 4D image acquisition and post processing to shorten exam time. These researchers have documented success at these efforts but, to the best of the current investigators' knowledge, such advanced imaging acquisition and post-processing systems are not readily commercially available in the US.
Recently GE teamed with Vios-Works for MRI to provide a cloud-based visualization platform for 4D MRI that provides quantitative and structured reporting in the post processing environment that makes use of advance MR imaging acquisition techniques. The images can be accessed by the interpreter and reviewed and manipulated in order to assess cardiac function and flow retrospectively, which, prior to this innovation, only has been available for computed tomography (CT) generated images.
This investigative team hypothesizes that the use of 4D imaging will result in reduced time for acquisition (approximately 6 minutes as opposed to 1 hour), and improvement of diagnostic capability.
Images will be acquired using the current standard 2D acquisition protocol for routine clinical cardiac MRI. A repeat acquisition will be completed using the new protocol for 4D imaging acquisition. This will require that patient exams be extended in length by six minutes for those enrolled in the study. The investigators will evaluate the image quality of the two techniques and grade them according to a scale of 1 to 3 with 1 being excellent cardiac borders easily identified; 2 - acceptable: cardiac borders acceptably identified; and 3, non-diagnostic. The investigators will specifically focus on the evaluation of cardiac function of both right and left ventricular function as well as flow analysis of both the aortic and pulmonic valves.
For each method, technician time and MD time will be collected. The exam will go through post processing for standard 2D, following by the new 4D post processing technique. Time for post processing will be collected. All subjects who agree will receive both a 2D and a 4D MRI. The investigators will evaluate inter and intra reader reliability by having all readers read the first 15 exams, and then read them a second time after two weeks in a different order Readers showing variation in performance will be retrained on interpretation of 4D MRI before reading scans for the study.
Once readers have been trained, the study will require that all 2D and 4D exams be read by two readers. The exams will be assigned randomly to readers using the Biostatistician Office random assignment services.
6. Conditions and Keywords
Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Cardiac Disease
7. Study Design
Primary Purpose
Diagnostic
Study Phase
Not Applicable
Interventional Study Model
Single Group Assignment
Model Description
Each participant will receive tradition 2D Cardiac imaging as ordered per standard of care. Then, the participant will receive a 4D image, requiring 6 to 10 additional minutes in the MRI scanner. The 2D and 4D images will be interpreted by readers blinded to the results of the alternate modality. Inter- and intra-reader reliability will be assessed.
Masking
None (Open Label)
Allocation
N/A
Enrollment
250 (Actual)
8. Arms, Groups, and Interventions
Arm Title
All Enrollees
Arm Type
Experimental
Arm Description
Intervention: Diagnostic test
All enrollees will receive a 4D MRI as a research intervention using imaging software for 4 dimensional images for Cardiac MRI
Intervention Type
Device
Intervention Name(s)
Imaging software for 4 dimensional images for Cardiac MRI
Intervention Description
All enrollees will receive Cardiac MRI scans using Imaging software for 4 dimensional images for Cardiac MRI
Primary Outcome Measure Information:
Title
2D imaging findings and medical diagnoses resulting from images.
Description
Investigators will count the number of study outcomes documented that are related to patient treatment.
Time Frame
Investigators are expected to interpret the 2D images in one sitting requiring 15 minutes to three hours, depending on exam complexity. The investigator will complete the scan review within 1 day to 1 month of the exam date.
Title
4D imaging findings and medical diagnoses resulting from images.
Description
Investigators will count the number of study outcomes documented that are related to patient treatment.
Time Frame
Investigators are expected to interpret the 4D images in one sitting requiring 15 minutes to three hours, depending on exam complexity. The investigator will complete the scan review within 1 day to 1 month of the exam date.
Secondary Outcome Measure Information:
Title
2D Time to scan acquisition
Description
Investigators will document time to acquire 2D image.
Time Frame
The 2D scan time will be from the time the 2D patient scan starts to the time the 2D patient scan ends. These will be measured on the patient's scheduled scan date.
Title
Time to 2D scan interpretation
Description
Time to interpret 2-D scan interpretation will be from the time the reader starts reading the 2D scan until the time the reader finishes reading the 2D scan.
Time Frame
The time required for the reader to interpret scan for 2D and to document results. Within one month of scan completion. Reader is expected to interpret each scan in 1 to 3 hours.
Title
Intra-reader reliability
Description
Each reader will read each scan assigned on two different dates. The reader will be blind to identity of scan. The two readings will be compared for consistency.
Time Frame
The reader will record all findings from each scan immediately upon completion of scan interpretation. Findings should be recorded within a month of the exam.
Title
Image quality
Description
Overall measure of all scan image quality based on standard quality assessment protocol definitions.
Time Frame
The reader will record an image score for each exam during interpretation of the scan. The reader will record an image score within one month of scan completion date.
Title
2D patient recommended treatments
Description
The reader will document recommendations for patient treatment based on 2D imaging results
Time Frame
The reader will recommend follow-up patient care for each patient based upon completion of the exam interpretation. The reader will record all recommendations within one month of the exam.
Title
90 day follow up
Description
Describe patient follow-up. The interviewer will record the patient follow up by interviewing the patient within 90 to 120 days of the scan and asking what follow up was taken; and by medical record review. Follow up will be recorded and will be compared to recommended follow up.
Time Frame
The interviewer will contact patients with a target date of 90 to 120 days after the exam to obtain the followup information via telephone.
Title
4D Time to scan acquisition
Description
Investigators will document time to acquire 4D image
Time Frame
The 4D scan time will be from the time the 4D patient scan starts to the time the 4D patient scan ends. These will be measured on the patients scheduled scan date.
Title
Time to 4D scan interpretation
Description
Time to interpret 4D scan interpretation will be from the time the reader starts reading the 4D scan until the time the reader finishes reading the 4D scan.
Time Frame
The time required for the reader to interpret scan for 4D and to document results. Within one month of scan completion. Reader is expected to interpret each scan in 1 to 3 hours.
Title
Inter-reader reliability
Description
Two readers will read each scan. The readers will be blind to identity of scan. the reader will not know the results reported by the second reader. The two readings will be compared for consistency.
Time Frame
The reader will record all findings from each scan immediately upon completion of scan interpretation. Findings should be recorded within a month of the exam.
Title
4D patient recommended treatments
Description
The reader will document recommendations for patient treatment based on 4D imaging results
Time Frame
The reader will recommend follow-up patient care for each patient based upon completion of the exam interpretation. The reader will record all recommendations within one month of the exam.
10. Eligibility
Sex
All
Minimum Age & Unit of Time
18 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria:
18 years of age or older
with a valid prescription for Cardiac MRI for the following: Congenital heart disease/Shunts, Valvular heart disease, Pulmonary Hypertension, Aortic Disease, Hypertrophic Cardiomyopathy (HCM)
receiving Standard of Care services at the MRI Center
consent to participate in the 4D trial
Exclusion Criteria:
Patients with any of the following will be excluded:
Pacemaker or ICD implanted
ICDs implanted
Temporary Pacemakers (e.g. transvenous temporary wires)
Leads that are abandoned (capped or retained leads not attached to device)
Non-transvenous leads (e.g. epicardial leads)
Leads that have no fixation (e.g. floating leads)
A lead that is known to be fractured
Any other metallic objects that, in the opinion of the safety officer would compromise patient safety
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Michael Poon, MD
Organizational Affiliation
Northwell Health
Official's Role
Principal Investigator
Facility Information:
Facility Name
Northwell Health Imaging at Greenwich Village: a Division of Lenox Hill Hospital
City
New York
State/Province
New York
ZIP/Postal Code
10011
Country
United States
12. IPD Sharing Statement
Plan to Share IPD
No
Citations:
PubMed Identifier
6833669
Citation
Okada RD, Lim YL, Rothendler J, Boucher CA, Block PC, Pohost GM. Split dose thallium-201 dipyridamole imaging: a new technique for obtaining thallium images before and immediately after an intervention. J Am Coll Cardiol. 1983 May;1(5):1302-10. doi: 10.1016/s0735-1097(83)80144-2. No abstract available.
Results Reference
background
PubMed Identifier
25708923
Citation
Vasanawala SS, Hanneman K, Alley MT, Hsiao A. Congenital heart disease assessment with 4D flow MRI. J Magn Reson Imaging. 2015 Oct;42(4):870-86. doi: 10.1002/jmri.24856. Epub 2015 Feb 24.
Results Reference
background
PubMed Identifier
21221566
Citation
Hsiao A, Alley MT, Massaband P, Herfkens RJ, Chan FP, Vasanawala SS. Improved cardiovascular flow quantification with time-resolved volumetric phase-contrast MRI. Pediatr Radiol. 2011 Jun;41(6):711-20. doi: 10.1007/s00247-010-1932-z. Epub 2011 Jan 11.
Results Reference
background
PubMed Identifier
22358022
Citation
Hsiao A, Lustig M, Alley MT, Murphy M, Chan FP, Herfkens RJ, Vasanawala SS. Rapid pediatric cardiac assessment of flow and ventricular volume with compressed sensing parallel imaging volumetric cine phase-contrast MRI. AJR Am J Roentgenol. 2012 Mar;198(3):W250-9. doi: 10.2214/AJR.11.6969.
Results Reference
background
PubMed Identifier
22923717
Citation
Hsiao A, Lustig M, Alley MT, Murphy MJ, Vasanawala SS. Evaluation of valvular insufficiency and shunts with parallel-imaging compressed-sensing 4D phase-contrast MR imaging with stereoscopic 3D velocity-fusion volume-rendered visualization. Radiology. 2012 Oct;265(1):87-95. doi: 10.1148/radiol.12120055. Epub 2012 Aug 24.
Results Reference
background
PubMed Identifier
25790878
Citation
Uretsky S, Gillam L, Lang R, Chaudhry FA, Argulian E, Supariwala A, Gurram S, Jain K, Subero M, Jang JJ, Cohen R, Wolff SD. Discordance between echocardiography and MRI in the assessment of mitral regurgitation severity: a prospective multicenter trial. J Am Coll Cardiol. 2015 Mar 24;65(11):1078-88. doi: 10.1016/j.jacc.2014.12.047.
Results Reference
background
PubMed Identifier
26257141
Citation
Dyverfeldt P, Bissell M, Barker AJ, Bolger AF, Carlhall CJ, Ebbers T, Francios CJ, Frydrychowicz A, Geiger J, Giese D, Hope MD, Kilner PJ, Kozerke S, Myerson S, Neubauer S, Wieben O, Markl M. 4D flow cardiovascular magnetic resonance consensus statement. J Cardiovasc Magn Reson. 2015 Aug 10;17(1):72. doi: 10.1186/s12968-015-0174-5.
Results Reference
background
Learn more about this trial
The Effectiveness of 4D Image Acquisition and Post-processing With Vios Works