The Prostate Immobilization Device Study
Primary Purpose
Adenocarcinoma of the Prostate
Status
Completed
Phase
Not Applicable
Locations
United States
Study Type
Interventional
Intervention
Miller Air tip
Radiadyne Immobilizer
Sponsored by
About this trial
This is an interventional treatment trial for Adenocarcinoma of the Prostate
Eligibility Criteria
Inclusion Criteria:
- 18 years of age or older
- Clinically localized T1-3 N0-1 M0 adenocarcinoma of the prostate
- Planned definitive radiation therapy
Exclusion Criteria:
- Prior proctectomy
- Rectal surgery within one year
- Proctitis
- Rectal carcinoma
- Anal Stenosis
- History of inflammatory bowel disease
- Scleroderma
- Systemic sclerosis
- Refusal of treatment with immobilization device
Sites / Locations
- Wheaton Francsican Cancer Care - All Saints
Arms of the Study
Arm 1
Arm 2
Arm Type
Active Comparator
Active Comparator
Arm Label
Miller enema air tip
Radiadyne Immobilizer
Arm Description
The Miller enema air tip rectal balloon is inserted into the rectum prior to radiation simulation and also prior to each radiation treatment to immobilize prostate gland and displace rectal tissue during radiation therapy.
The Radiadyne Immobilizer Treatment Device is inserted into the rectum prior to radiation simulation and also prior to each radiation treatment to immobilize prostate gland and displace rectal tissue during radiation therapy
Outcomes
Primary Outcome Measures
Deviation of the Prostate Rectal Interface From Its Position at Time of Simulation.
Measurements will be taken for at least 5, and up to 9, occasions on a weekly basis during each patient's course of treatment. An average value will be determined for each patient. An average of individual patient values will be determined for each immobilization device.
Secondary Outcome Measures
Difficulty of Insertion.
Difficulty of device insertion was scored for each treatment by the treating radiation therapist on a scale from 1(easiest) to 5(most difficult). An average score was obtained at completion of therapy for each patient. At completion of the study, an average value was obtained for each immobilization device by averaging the average score for each patient .
Patient Expression of Discomfort
Patient expression of discomfort was scored for each insertion by the treating radiation therapist on a scale from 1(none) to 5(intolerable). An average score was obtained at completion of therapy for each patient. At completion of the study, an average value was obtained for each immobilization device by averaging the average score for each patient .
Full Information
1. Study Identification
Unique Protocol Identification Number
NCT01408706
Brief Title
The Prostate Immobilization Device Study
Official Title
The Prostate Immobilization Device Study
Study Type
Interventional
2. Study Status
Record Verification Date
June 2017
Overall Recruitment Status
Completed
Study Start Date
August 2011 (undefined)
Primary Completion Date
October 2014 (Actual)
Study Completion Date
October 2014 (Actual)
3. Sponsor/Collaborators
Responsible Party, by Official Title
Sponsor-Investigator
Name of the Sponsor
James Taylor
4. Oversight
Data Monitoring Committee
No
5. Study Description
Brief Summary
The purpose of this study is to compare reproducibility of the device position and location of the prostate rectum interface between two immobilization devices for radiation therapy of prostate carcinoma.
Detailed Description
The investigator assessed the device position and location of the interface between rectum and prostate weekly during the course of treatment. This information was obtained using a conebeam CT scan on the treatment couch prior to a regularly scheduled radiation treatment. The conebeam CT scan is a standard tool for monitoring patient position and radiation treatment accuracy. Prior to each radiation treatment, the patient was placed in a vaclock immobilization device, then aligned with room lasers to skin tattoos. On board portal imaging was then employed using the KvKv match technique to place isocenter as simulated. For intact prostate treatment, alignment was made to implanted gold fiducial markers. For post prostatectomy patients, the alignment was to pelvic bony anatomy. After patient alignment was complete, a conebeam CT scan was obtained. The position of the anterior rectal wall and the interface between prostate and rectum was compared to the position of these structures at the time of simulation. Measurement was taken in the midline of the prostate gland between its base and apex of the maximum deviation of the rectum prostate interface from its position at the time of simulation. For post prostatectomy patients, a measurement was taken of the maximum deviation from simulation of interface between the rectum and the prostate bed/bladder. These measurements were recorded weekly by the treating radiation oncologist on the Physician Data Sheet.
The difficulty of device insertion, positioning and inflation was recorded daily by the treating personnel based on a scale in the PIDS Daily Radiation Therapist Questionnaire, from 1(none) to 5(unable to insert). These results were summarized by the clinical study coordinators on the PIDS Radiation Therapist Summary.
Patient expression of discomfort during device placement was recorded daily by treating personnel based on a scale in the PIDS Daily Radiation Therapist Questionnaire, from 1(none) to 5(intolerable). These responses will be summarized by the clinical study coordinators on the PIDS Radiation Therapist Summary.
6. Conditions and Keywords
Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Adenocarcinoma of the Prostate
7. Study Design
Primary Purpose
Treatment
Study Phase
Not Applicable
Interventional Study Model
Parallel Assignment
Masking
None (Open Label)
Allocation
Randomized
Enrollment
60 (Actual)
8. Arms, Groups, and Interventions
Arm Title
Miller enema air tip
Arm Type
Active Comparator
Arm Description
The Miller enema air tip rectal balloon is inserted into the rectum prior to radiation simulation and also prior to each radiation treatment to immobilize prostate gland and displace rectal tissue during radiation therapy.
Arm Title
Radiadyne Immobilizer
Arm Type
Active Comparator
Arm Description
The Radiadyne Immobilizer Treatment Device is inserted into the rectum prior to radiation simulation and also prior to each radiation treatment to immobilize prostate gland and displace rectal tissue during radiation therapy
Intervention Type
Device
Intervention Name(s)
Miller Air tip
Other Intervention Name(s)
Miller Enema Air Tip
Intervention Description
Miller Enema Air Tip is inserted into rectum prior to simulation and each radiation treatment.
Intervention Type
Device
Intervention Name(s)
Radiadyne Immobilizer
Intervention Description
Radiadyne Immobilizer is inserted into rectum prior to simulation and each radiation treatment
Primary Outcome Measure Information:
Title
Deviation of the Prostate Rectal Interface From Its Position at Time of Simulation.
Description
Measurements will be taken for at least 5, and up to 9, occasions on a weekly basis during each patient's course of treatment. An average value will be determined for each patient. An average of individual patient values will be determined for each immobilization device.
Time Frame
Up to 9 weeks
Secondary Outcome Measure Information:
Title
Difficulty of Insertion.
Description
Difficulty of device insertion was scored for each treatment by the treating radiation therapist on a scale from 1(easiest) to 5(most difficult). An average score was obtained at completion of therapy for each patient. At completion of the study, an average value was obtained for each immobilization device by averaging the average score for each patient .
Time Frame
Up to nine weeks
Title
Patient Expression of Discomfort
Description
Patient expression of discomfort was scored for each insertion by the treating radiation therapist on a scale from 1(none) to 5(intolerable). An average score was obtained at completion of therapy for each patient. At completion of the study, an average value was obtained for each immobilization device by averaging the average score for each patient .
Time Frame
Up to nine weeks
10. Eligibility
Sex
Male
Minimum Age & Unit of Time
18 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria:
18 years of age or older
Clinically localized T1-3 N0-1 M0 adenocarcinoma of the prostate
Planned definitive radiation therapy
Exclusion Criteria:
Prior proctectomy
Rectal surgery within one year
Proctitis
Rectal carcinoma
Anal Stenosis
History of inflammatory bowel disease
Scleroderma
Systemic sclerosis
Refusal of treatment with immobilization device
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
James H Taylor, MD
Organizational Affiliation
Wheaton Franciscan Cancer Care - All Saints
Official's Role
Principal Investigator
Facility Information:
Facility Name
Wheaton Francsican Cancer Care - All Saints
City
Racine
State/Province
Wisconsin
ZIP/Postal Code
53405
Country
United States
12. IPD Sharing Statement
Plan to Share IPD
No
Learn more about this trial
The Prostate Immobilization Device Study
We'll reach out to this number within 24 hrs