Trans-pulmonary Pressure in ARDS (T3P)
Primary Purpose
Acute Respiratory Distress Syndrome
Status
Completed
Phase
Not Applicable
Locations
France
Study Type
Interventional
Intervention
level of positive end expiratory pressure (Prone Proseva)
level of positive end expiratory pressure (Prone Talmor)
Sponsored by
About this trial
This is an interventional treatment trial for Acute Respiratory Distress Syndrome focused on measuring ARDS, prone position, PEEP, mechanical ventilation
Eligibility Criteria
Inclusion Criteria:
- ARDS
- intubated
- indication of proning
- no contra-indication of proning
Exclusion Criteria:
- contra-indication to proning
- contra-indication to esophageal balloon
- proning before
- end of life decision
- legal protection
- pregnancy
- ECMO
Sites / Locations
- Hôpital de la Croix Rousse
- Hôpital de la Croix-Rousse
Arms of the Study
Arm 1
Arm 2
Arm Type
Experimental
Active Comparator
Arm Label
Prone Proseva
Prone Talmor
Arm Description
Outcomes
Primary Outcome Measures
Value of the esophageal pressure measured at the end of expiration
Oesophageal pressure is measured from a balloon inserted into the mid oesophagus at the end of expiration. Its value is subtracted to the airway pressure at the end of expiration leading to trans-pulmonary pressure at the end of expiration (Ptp,ee). The measurements are done first in the supine position. In the standardized condition PEEP is set from a PEEP/FIO2 table and Ptp,ee is measured. In the Talmor approach PEEP is set to obtain Ptp,ee between 0 and 10 cm H2O. The patient is then turned to the prone position. The measurements are repeated in the same way. Then for the rest of the proning session the patient receive either level of PEEP from each strategy. Measurements are repeated at the end of the session.
Value of the esophageal pressure measured at the end of expiration
Oesophageal pressure is measured from a balloon inserted into the mid oesophagus at the end of expiration. Its value is subtracted to the airway pressure at the end of expiration leading to trans-pulmonary pressure at the end of expiration (Ptp,ee). The measurements are done first in the supine position. In the standardized condition PEEP is set from a PEEP/FIO2 table and Ptp,ee is measured. In the Talmor approach PEEP is set to obtain Ptp,ee between 0 and 10 cm H2O. The patient is then turned to the prone position. The measurements are repeated in the same way. Then for the rest of the proning session the patient receive either level of PEEP from each strategy. Measurements are repeated at the end of the session.
Value of the esophageal pressure measured at the end of expiration
Oesophageal pressure is measured from a balloon inserted into the mid oesophagus at the end of expiration. Its value is subtracted to the airway pressure at the end of expiration leading to trans-pulmonary pressure at the end of expiration (Ptp,ee). The measurements are done first in the supine position. In the standardized condition PEEP is set from a PEEP/FIO2 table and Ptp,ee is measured. In the Talmor approach PEEP is set to obtain Ptp,ee between 0 and 10 cm H2O. The patient is then turned to the prone position. The measurements are repeated in the same way. Then for the rest of the proning session the patient receive either level of PEEP from each strategy. Measurements are repeated at the end of the session.
Value of the esophageal pressure measured at the end of expiration
Oesophageal pressure is measured from a balloon inserted into the mid oesophagus at the end of expiration. Its value is subtracted to the airway pressure at the end of expiration leading to trans-pulmonary pressure at the end of expiration (Ptp,ee). The measurements are done first in the supine position. In the standardized condition PEEP is set from a PEEP/FIO2 table and Ptp,ee is measured. In the Talmor approach PEEP is set to obtain Ptp,ee between 0 and 10 cm H2O. The patient is then turned to the prone position. The measurements are repeated in the same way. Then for the rest of the proning session the patient receive either level of PEEP from each strategy. Measurements are repeated at the end of the session.
Value of the esophageal pressure measured at the end of expiration
Oesophageal pressure is measured from a balloon inserted into the mid oesophagus at the end of expiration. Its value is subtracted to the airway pressure at the end of expiration leading to trans-pulmonary pressure at the end of expiration (Ptp,ee). The measurements are done first in the supine position. In the standardized condition PEEP is set from a PEEP/FIO2 table and Ptp,ee is measured. In the Talmor approach PEEP is set to obtain Ptp,ee between 0 and 10 cm H2O. The patient is then turned to the prone position. The measurements are repeated in the same way. Then for the rest of the proning session the patient receive either level of PEEP from each strategy. Measurements are repeated at the end of the session.
Secondary Outcome Measures
Elastance of the chest wall
The elastance of the chest wall is the change in esophageal pressure between expiration and inspiration in response to a change in lung volume. It is not substantially changed by PEEP but it is by the change in position.
Elastance of the chest wall
The elastance of the chest wall is the change in esophageal pressure between expiration and inspiration in response to a change in lung volume. It is not substantially changed by PEEP but it is by the change in position.
Elastance of the chest wall
The elastance of the chest wall is the change in esophageal pressure between expiration and inspiration in response to a change in lung volume. It is not substantially changed by PEEP but it is by the change in position.
Elastance of the chest wall
The elastance of the chest wall is the change in esophageal pressure between expiration and inspiration in response to a change in lung volume. It is not substantially changed by PEEP but it is by the change in position.
Elastance of the chest wall
The elastance of the chest wall is the change in esophageal pressure between expiration and inspiration in response to a change in lung volume. It is not substantially changed by PEEP but it is by the change in position.
Transpulmonary pressure at the end of expiration (Ptp,ee)
In the standardized condition, either in supine or prone, the transpulmonary pressure is the difference between airway pressure and esophageal pressure at the end of expiration. In the standardized approach, PEEP is set according to a PEEP/FIO2 table and Ptp,ee is dependent on the PEEP/FIO2 table. With the Talmor approach, Ptp,ee is directly set from measurement of esophageal pressure and PEEP set according to the PEEP/FIO2 table.
Transpulmonary pressure at the end of expiration (Ptp,ee)
In the standardized condition, either in supine or prone, the transpulmonary pressure is the difference between airway pressure and esophageal pressure at the end of expiration. In the standardized approach, PEEP is set according to a PEEP/FIO2 table and Ptp,ee is dependent on the PEEP/FIO2 table. With the Talmor approach, Ptp,ee is directly set from measurement of esophageal pressure and PEEP set according to the PEEP/FIO2 table.
Transpulmonary pressure at the end of expiration (Ptp,ee)
In the standardized condition, either in supine or prone, the transpulmonary pressure is the difference between airway pressure and esophageal pressure at the end of expiration. In the standardized approach, PEEP is set according to a PEEP/FIO2 table and Ptp,ee is dependent on the PEEP/FIO2 table. With the Talmor approach, Ptp,ee is directly set from measurement of esophageal pressure and PEEP set according to the PEEP/FIO2 table.
Transpulmonary pressure at the end of expiration (Ptp,ee)
In the standardized condition, either in supine or prone, the transpulmonary pressure is the difference between airway pressure and esophageal pressure at the end of expiration. In the standardized approach, PEEP is set according to a PEEP/FIO2 table and Ptp,ee is dependent on the PEEP/FIO2 table. With the Talmor approach, Ptp,ee is directly set from measurement of esophageal pressure and PEEP set according to the PEEP/FIO2 table.
Transpulmonary pressure at the end of expiration (Ptp,ee)
In the standardized condition, either in supine or prone, the transpulmonary pressure is the difference between airway pressure and esophageal pressure at the end of expiration. In the standardized approach, PEEP is set according to a PEEP/FIO2 table and Ptp,ee is dependent on the PEEP/FIO2 table. With the Talmor approach, Ptp,ee is directly set from measurement of esophageal pressure and PEEP set according to the PEEP/FIO2 table.
End expiratory lung volume (EELV)
EELV is the volume of gas at the end of expiration. It is measured from the ventilator by using the washout-washin technique after a small change in the FIO2. An increase in EELV can indicate recruitment (reopening of non aerated lung tissue) but some overinflation may also contribute to this increase. PEEP and prone position can increase EELV.
End expiratory lung volume (EELV)
EELV is the volume of gas at the end of expiration. It is measured from the ventilator by using the washout-washin technique after a small change in the FIO2. An increase in EELV can indicate recruitment (reopening of non aerated lung tissue) but some overinflation may also contribute to this increase. PEEP and prone position can increase EELV.
End expiratory lung volume (EELV)
EELV is the volume of gas at the end of expiration. It is measured from the ventilator by using the washout-washin technique after a small change in the FIO2. An increase in EELV can indicate recruitment (reopening of non aerated lung tissue) but some overinflation may also contribute to this increase. PEEP and prone position can increase EELV.
End expiratory lung volume (EELV)
EELV is the volume of gas at the end of expiration. It is measured from the ventilator by using the washout-washin technique after a small change in the FIO2. An increase in EELV can indicate recruitment (reopening of non aerated lung tissue) but some overinflation may also contribute to this increase. PEEP and prone position can increase EELV.
End expiratory lung volume (EELV)
EELV is the volume of gas at the end of expiration. It is measured from the ventilator by using the washout-washin technique after a small change in the FIO2. An increase in EELV can indicate recruitment (reopening of non aerated lung tissue) but some overinflation may also contribute to this increase. PEEP and prone position can increase EELV.
Regional lung ventilation
regional ventilation is measured by using electrical impedance tomography. The change in thoracic impedance in response to electric current of small amplitude (50 ms) is proportional to amount of air among other factors, which are less important in magnitude as compared to air. The lung is sampled into anterior and posterior regions. The location of better aeration with PEEP and position will be mapped.
Regional lung ventilation
regional ventilation is measured by using electrical impedance tomography. The change in thoracic impedance in response to electric current of small amplitude (50 ms) is proportional to amount of air among other factors, which are less important in magnitude as compared to air. The lung is sampled into anterior and posterior regions. The location of better aeration with PEEP and position will be mapped.
Regional lung ventilation
regional ventilation is measured by using electrical impedance tomography. The change in thoracic impedance in response to electric current of small amplitude (50 ms) is proportional to amount of air among other factors, which are less important in magnitude as compared to air. The lung is sampled into anterior and posterior regions. The location of better aeration with PEEP and position will be mapped.
Regional lung ventilation
regional ventilation is measured by using electrical impedance tomography. The change in thoracic impedance in response to electric current of small amplitude (50 ms) is proportional to amount of air among other factors, which are less important in magnitude as compared to air. The lung is sampled into anterior and posterior regions. The location of better aeration with PEEP and position will be mapped.
Regional lung ventilation
regional ventilation is measured by using electrical impedance tomography. The change in thoracic impedance in response to electric current of small amplitude (50 ms) is proportional to amount of air among other factors, which are less important in magnitude as compared to air. The lung is sampled into anterior and posterior regions. The location of better aeration with PEEP and position will be mapped.
Full Information
NCT ID
NCT02416037
First Posted
April 3, 2015
Last Updated
February 27, 2018
Sponsor
Hospices Civils de Lyon
1. Study Identification
Unique Protocol Identification Number
NCT02416037
Brief Title
Trans-pulmonary Pressure in ARDS
Acronym
T3P
Official Title
Trans-Pulmonary Pressure and Prone Position in Ards Patients
Study Type
Interventional
2. Study Status
Record Verification Date
February 2018
Overall Recruitment Status
Completed
Study Start Date
January 2016 (undefined)
Primary Completion Date
April 13, 2017 (Actual)
Study Completion Date
April 13, 2017 (Actual)
3. Sponsor/Collaborators
Responsible Party, by Official Title
Sponsor
Name of the Sponsor
Hospices Civils de Lyon
4. Oversight
Data Monitoring Committee
No
5. Study Description
Brief Summary
Adequate PEEP selection in ARDS is still a matter of research. The main objectives of using PEEP in ARDS are improvement in oxygenation, lung recruitment at the end of expiration, prevention of opening and closing of terminal respiratory units at minimal hemodynamic compromise. The challenge is to carry out these objectives in a patient-centered approach based on individual characteristic of lung pathophysiology. Recently, it has been proposed to set PEEP from the trans-pulmonary end-expiratory pressure. Trans-pulmonary pressure (Ptp) is obtained from the difference between airway pressure and measured esophageal pressure (Pes). Measured Pes values have been found positive in the supine position in ARDS patients, leading to negative values of Ptp. The strategy proposed by Talmor and coworkers is to adjust PEEP up to get Ptp between 0 and 10 cm H2O. Whether this strategy improves survival is under investigation. Prone position ventilation significantly improves survival in severe ARDS as demonstrated by meta-analyses and a recent multicenter randomized controlled trial.
The purpose of present project is to investigate Ptp at end-expiration in the prone position in severe ARDS. The project is centered on the question about what are the values of measured Pes in prone position. The hypothesis is that they are lower than in the supine position due to the relief of the weight of heart, mediastinum and lung and also to recruitment of dorsal lung regions. To investigate this hypothesis, measured Pes, Ptp, end-expiratory lung volume, overall lung recruitment (pressure-volume curve), and regional recruitment by using electrical impedance tomography. will be assessed in supine then in the prone position across two different strategies of PEEP selection, PEEP/FIO2 table and Talmor proposal.
6. Conditions and Keywords
Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Acute Respiratory Distress Syndrome
Keywords
ARDS, prone position, PEEP, mechanical ventilation
7. Study Design
Primary Purpose
Treatment
Study Phase
Not Applicable
Interventional Study Model
Parallel Assignment
Masking
Participant
Allocation
Randomized
Enrollment
32 (Actual)
8. Arms, Groups, and Interventions
Arm Title
Prone Proseva
Arm Type
Experimental
Arm Title
Prone Talmor
Arm Type
Active Comparator
Intervention Type
Device
Intervention Name(s)
level of positive end expiratory pressure (Prone Proseva)
Intervention Description
PEEP based on PEEP/FIO2 table vs PEEP based on the value of oesophageal pressure
Intervention Type
Device
Intervention Name(s)
level of positive end expiratory pressure (Prone Talmor)
Intervention Description
PEEP based on PEEP/FIO2 table vs PEEP based on the value of oesophageal pressure
Primary Outcome Measure Information:
Title
Value of the esophageal pressure measured at the end of expiration
Description
Oesophageal pressure is measured from a balloon inserted into the mid oesophagus at the end of expiration. Its value is subtracted to the airway pressure at the end of expiration leading to trans-pulmonary pressure at the end of expiration (Ptp,ee). The measurements are done first in the supine position. In the standardized condition PEEP is set from a PEEP/FIO2 table and Ptp,ee is measured. In the Talmor approach PEEP is set to obtain Ptp,ee between 0 and 10 cm H2O. The patient is then turned to the prone position. The measurements are repeated in the same way. Then for the rest of the proning session the patient receive either level of PEEP from each strategy. Measurements are repeated at the end of the session.
Time Frame
6.5 hours after inclusion
Title
Value of the esophageal pressure measured at the end of expiration
Description
Oesophageal pressure is measured from a balloon inserted into the mid oesophagus at the end of expiration. Its value is subtracted to the airway pressure at the end of expiration leading to trans-pulmonary pressure at the end of expiration (Ptp,ee). The measurements are done first in the supine position. In the standardized condition PEEP is set from a PEEP/FIO2 table and Ptp,ee is measured. In the Talmor approach PEEP is set to obtain Ptp,ee between 0 and 10 cm H2O. The patient is then turned to the prone position. The measurements are repeated in the same way. Then for the rest of the proning session the patient receive either level of PEEP from each strategy. Measurements are repeated at the end of the session.
Time Frame
8.0 hours after inclusion
Title
Value of the esophageal pressure measured at the end of expiration
Description
Oesophageal pressure is measured from a balloon inserted into the mid oesophagus at the end of expiration. Its value is subtracted to the airway pressure at the end of expiration leading to trans-pulmonary pressure at the end of expiration (Ptp,ee). The measurements are done first in the supine position. In the standardized condition PEEP is set from a PEEP/FIO2 table and Ptp,ee is measured. In the Talmor approach PEEP is set to obtain Ptp,ee between 0 and 10 cm H2O. The patient is then turned to the prone position. The measurements are repeated in the same way. Then for the rest of the proning session the patient receive either level of PEEP from each strategy. Measurements are repeated at the end of the session.
Time Frame
10 hours after inclusion
Title
Value of the esophageal pressure measured at the end of expiration
Description
Oesophageal pressure is measured from a balloon inserted into the mid oesophagus at the end of expiration. Its value is subtracted to the airway pressure at the end of expiration leading to trans-pulmonary pressure at the end of expiration (Ptp,ee). The measurements are done first in the supine position. In the standardized condition PEEP is set from a PEEP/FIO2 table and Ptp,ee is measured. In the Talmor approach PEEP is set to obtain Ptp,ee between 0 and 10 cm H2O. The patient is then turned to the prone position. The measurements are repeated in the same way. Then for the rest of the proning session the patient receive either level of PEEP from each strategy. Measurements are repeated at the end of the session.
Time Frame
11.5 hours after inclusion
Title
Value of the esophageal pressure measured at the end of expiration
Description
Oesophageal pressure is measured from a balloon inserted into the mid oesophagus at the end of expiration. Its value is subtracted to the airway pressure at the end of expiration leading to trans-pulmonary pressure at the end of expiration (Ptp,ee). The measurements are done first in the supine position. In the standardized condition PEEP is set from a PEEP/FIO2 table and Ptp,ee is measured. In the Talmor approach PEEP is set to obtain Ptp,ee between 0 and 10 cm H2O. The patient is then turned to the prone position. The measurements are repeated in the same way. Then for the rest of the proning session the patient receive either level of PEEP from each strategy. Measurements are repeated at the end of the session.
Time Frame
up to 26.5 hours after inclusion
Secondary Outcome Measure Information:
Title
Elastance of the chest wall
Description
The elastance of the chest wall is the change in esophageal pressure between expiration and inspiration in response to a change in lung volume. It is not substantially changed by PEEP but it is by the change in position.
Time Frame
6.5 hours after inclusion
Title
Elastance of the chest wall
Description
The elastance of the chest wall is the change in esophageal pressure between expiration and inspiration in response to a change in lung volume. It is not substantially changed by PEEP but it is by the change in position.
Time Frame
8.0 hours after inclusion
Title
Elastance of the chest wall
Description
The elastance of the chest wall is the change in esophageal pressure between expiration and inspiration in response to a change in lung volume. It is not substantially changed by PEEP but it is by the change in position.
Time Frame
10 hours after inclusion
Title
Elastance of the chest wall
Description
The elastance of the chest wall is the change in esophageal pressure between expiration and inspiration in response to a change in lung volume. It is not substantially changed by PEEP but it is by the change in position.
Time Frame
11.5 hours after inclusion
Title
Elastance of the chest wall
Description
The elastance of the chest wall is the change in esophageal pressure between expiration and inspiration in response to a change in lung volume. It is not substantially changed by PEEP but it is by the change in position.
Time Frame
up to 26.5 hours after inclusion
Title
Transpulmonary pressure at the end of expiration (Ptp,ee)
Description
In the standardized condition, either in supine or prone, the transpulmonary pressure is the difference between airway pressure and esophageal pressure at the end of expiration. In the standardized approach, PEEP is set according to a PEEP/FIO2 table and Ptp,ee is dependent on the PEEP/FIO2 table. With the Talmor approach, Ptp,ee is directly set from measurement of esophageal pressure and PEEP set according to the PEEP/FIO2 table.
Time Frame
6.5 hours after inclusion
Title
Transpulmonary pressure at the end of expiration (Ptp,ee)
Description
In the standardized condition, either in supine or prone, the transpulmonary pressure is the difference between airway pressure and esophageal pressure at the end of expiration. In the standardized approach, PEEP is set according to a PEEP/FIO2 table and Ptp,ee is dependent on the PEEP/FIO2 table. With the Talmor approach, Ptp,ee is directly set from measurement of esophageal pressure and PEEP set according to the PEEP/FIO2 table.
Time Frame
8.0 hours after inclusion
Title
Transpulmonary pressure at the end of expiration (Ptp,ee)
Description
In the standardized condition, either in supine or prone, the transpulmonary pressure is the difference between airway pressure and esophageal pressure at the end of expiration. In the standardized approach, PEEP is set according to a PEEP/FIO2 table and Ptp,ee is dependent on the PEEP/FIO2 table. With the Talmor approach, Ptp,ee is directly set from measurement of esophageal pressure and PEEP set according to the PEEP/FIO2 table.
Time Frame
10 hours after inclusion
Title
Transpulmonary pressure at the end of expiration (Ptp,ee)
Description
In the standardized condition, either in supine or prone, the transpulmonary pressure is the difference between airway pressure and esophageal pressure at the end of expiration. In the standardized approach, PEEP is set according to a PEEP/FIO2 table and Ptp,ee is dependent on the PEEP/FIO2 table. With the Talmor approach, Ptp,ee is directly set from measurement of esophageal pressure and PEEP set according to the PEEP/FIO2 table.
Time Frame
11.5 hours after inclusion
Title
Transpulmonary pressure at the end of expiration (Ptp,ee)
Description
In the standardized condition, either in supine or prone, the transpulmonary pressure is the difference between airway pressure and esophageal pressure at the end of expiration. In the standardized approach, PEEP is set according to a PEEP/FIO2 table and Ptp,ee is dependent on the PEEP/FIO2 table. With the Talmor approach, Ptp,ee is directly set from measurement of esophageal pressure and PEEP set according to the PEEP/FIO2 table.
Time Frame
up to 26.5 hours after inclusion
Title
End expiratory lung volume (EELV)
Description
EELV is the volume of gas at the end of expiration. It is measured from the ventilator by using the washout-washin technique after a small change in the FIO2. An increase in EELV can indicate recruitment (reopening of non aerated lung tissue) but some overinflation may also contribute to this increase. PEEP and prone position can increase EELV.
Time Frame
6.5 hours after inclusion
Title
End expiratory lung volume (EELV)
Description
EELV is the volume of gas at the end of expiration. It is measured from the ventilator by using the washout-washin technique after a small change in the FIO2. An increase in EELV can indicate recruitment (reopening of non aerated lung tissue) but some overinflation may also contribute to this increase. PEEP and prone position can increase EELV.
Time Frame
8.0 hours after inclusion
Title
End expiratory lung volume (EELV)
Description
EELV is the volume of gas at the end of expiration. It is measured from the ventilator by using the washout-washin technique after a small change in the FIO2. An increase in EELV can indicate recruitment (reopening of non aerated lung tissue) but some overinflation may also contribute to this increase. PEEP and prone position can increase EELV.
Time Frame
10 hours after inclusion
Title
End expiratory lung volume (EELV)
Description
EELV is the volume of gas at the end of expiration. It is measured from the ventilator by using the washout-washin technique after a small change in the FIO2. An increase in EELV can indicate recruitment (reopening of non aerated lung tissue) but some overinflation may also contribute to this increase. PEEP and prone position can increase EELV.
Time Frame
11.5 hours after inclusion
Title
End expiratory lung volume (EELV)
Description
EELV is the volume of gas at the end of expiration. It is measured from the ventilator by using the washout-washin technique after a small change in the FIO2. An increase in EELV can indicate recruitment (reopening of non aerated lung tissue) but some overinflation may also contribute to this increase. PEEP and prone position can increase EELV.
Time Frame
up to 26.5 hours after inclusion
Title
Regional lung ventilation
Description
regional ventilation is measured by using electrical impedance tomography. The change in thoracic impedance in response to electric current of small amplitude (50 ms) is proportional to amount of air among other factors, which are less important in magnitude as compared to air. The lung is sampled into anterior and posterior regions. The location of better aeration with PEEP and position will be mapped.
Time Frame
6.5 hours after inclusion
Title
Regional lung ventilation
Description
regional ventilation is measured by using electrical impedance tomography. The change in thoracic impedance in response to electric current of small amplitude (50 ms) is proportional to amount of air among other factors, which are less important in magnitude as compared to air. The lung is sampled into anterior and posterior regions. The location of better aeration with PEEP and position will be mapped.
Time Frame
8.0 hours after inclusion
Title
Regional lung ventilation
Description
regional ventilation is measured by using electrical impedance tomography. The change in thoracic impedance in response to electric current of small amplitude (50 ms) is proportional to amount of air among other factors, which are less important in magnitude as compared to air. The lung is sampled into anterior and posterior regions. The location of better aeration with PEEP and position will be mapped.
Time Frame
10 hours after inclusion
Title
Regional lung ventilation
Description
regional ventilation is measured by using electrical impedance tomography. The change in thoracic impedance in response to electric current of small amplitude (50 ms) is proportional to amount of air among other factors, which are less important in magnitude as compared to air. The lung is sampled into anterior and posterior regions. The location of better aeration with PEEP and position will be mapped.
Time Frame
11.5 hours after inclusion
Title
Regional lung ventilation
Description
regional ventilation is measured by using electrical impedance tomography. The change in thoracic impedance in response to electric current of small amplitude (50 ms) is proportional to amount of air among other factors, which are less important in magnitude as compared to air. The lung is sampled into anterior and posterior regions. The location of better aeration with PEEP and position will be mapped.
Time Frame
up to 26.5 hours after inclusion
10. Eligibility
Sex
All
Minimum Age & Unit of Time
18 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria:
ARDS
intubated
indication of proning
no contra-indication of proning
Exclusion Criteria:
contra-indication to proning
contra-indication to esophageal balloon
proning before
end of life decision
legal protection
pregnancy
ECMO
Facility Information:
Facility Name
Hôpital de la Croix Rousse
City
Lyon
ZIP/Postal Code
69004
Country
France
Facility Name
Hôpital de la Croix-Rousse
City
Lyon
ZIP/Postal Code
69004
Country
France
12. IPD Sharing Statement
Learn more about this trial
Trans-pulmonary Pressure in ARDS
We'll reach out to this number within 24 hrs