search
Back to results

Transfer Accuracy of Indirectly Bonded Orthodontic Braces With Different Transfer Trays

Primary Purpose

Malocclusion

Status
Completed
Phase
Not Applicable
Locations
Turkey
Study Type
Interventional
Intervention
Indirect bonding
Sponsored by
Yuzuncu Yıl University
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional treatment trial for Malocclusion focused on measuring Indirect bonding, Accuracy

Eligibility Criteria

15 Years - 20 Years (Child, Adult)All SexesDoes not accept healthy volunteers

Inclusion Criteria:

  • The presence of indication for both arches to be bonded in the same appointment

Exclusion Criteria:

  • Presence of restorations, hypoplasia or decalcification on vestibular tooth surfaces
  • Abnormal crown morphology

Sites / Locations

  • Cihan Aydoğan

Arms of the Study

Arm 1

Arm 2

Arm Type

Experimental

Active Comparator

Arm Label

Silicone

Vacuum formed

Arm Description

Indirect bonding performed with the silicone trays

Indirect bonding performed with the vacuum formed trays

Outcomes

Primary Outcome Measures

Transfer accuracy (composite outcome) in milimetres and degrees. Which is measured on computer software.
The positional deviations between the attachments on the models and the mouth

Secondary Outcome Measures

Full Information

First Posted
November 19, 2018
Last Updated
November 22, 2018
Sponsor
Yuzuncu Yıl University
search

1. Study Identification

Unique Protocol Identification Number
NCT03754283
Brief Title
Transfer Accuracy of Indirectly Bonded Orthodontic Braces With Different Transfer Trays
Official Title
Transfer Accuracy of Indirectly Bonded Orthodontic Attachments With Vacuum Formed and Silicone Transfer Trays
Study Type
Interventional

2. Study Status

Record Verification Date
November 2018
Overall Recruitment Status
Completed
Study Start Date
June 1, 2017 (Actual)
Primary Completion Date
September 1, 2017 (Actual)
Study Completion Date
September 1, 2017 (Actual)

3. Sponsor/Collaborators

Responsible Party, by Official Title
Principal Investigator
Name of the Sponsor
Yuzuncu Yıl University

4. Oversight

Studies a U.S. FDA-regulated Drug Product
No
Studies a U.S. FDA-regulated Device Product
No
Data Monitoring Committee
No

5. Study Description

Brief Summary
The aim of this study is to comparatively investigate the performances of two different and widely used transfer trays during indirect bonding of the orthodontic braces.
Detailed Description
The aim of the study is to compare the accuracy of orthodontic bracket and tube transfer between double layer silicone and double layer vacuum formed trays. The sample included 368 attachments bonded in 16 patients. Each patient received one silicone and one vacuum formed tray which were randomly allocated to provide 8 trays of each type for the upper and lower arches. 3D scan data and local best-fit alignments were used to calculate the translational and rotational movements of the orthodontic attachments. Chi-square and Mann-Whitney U tests were used to compare transfer accuracy and success between the groups.

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Malocclusion
Keywords
Indirect bonding, Accuracy

7. Study Design

Primary Purpose
Treatment
Study Phase
Not Applicable
Interventional Study Model
Parallel Assignment
Model Description
1:1
Masking
Outcomes Assessor
Allocation
Randomized
Enrollment
16 (Actual)

8. Arms, Groups, and Interventions

Arm Title
Silicone
Arm Type
Experimental
Arm Description
Indirect bonding performed with the silicone trays
Arm Title
Vacuum formed
Arm Type
Active Comparator
Arm Description
Indirect bonding performed with the vacuum formed trays
Intervention Type
Device
Intervention Name(s)
Indirect bonding
Intervention Description
Indirect bonding is the technique where orthodontic appliances are first placed on a model of the patient and then transferred to the patient using some kinf of trays
Primary Outcome Measure Information:
Title
Transfer accuracy (composite outcome) in milimetres and degrees. Which is measured on computer software.
Description
The positional deviations between the attachments on the models and the mouth
Time Frame
Day 0 - Day 2

10. Eligibility

Sex
All
Minimum Age & Unit of Time
15 Years
Maximum Age & Unit of Time
20 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria: The presence of indication for both arches to be bonded in the same appointment Exclusion Criteria: Presence of restorations, hypoplasia or decalcification on vestibular tooth surfaces Abnormal crown morphology
Facility Information:
Facility Name
Cihan Aydoğan
City
Van
ZIP/Postal Code
65080
Country
Turkey

12. IPD Sharing Statement

Plan to Share IPD
No

Learn more about this trial

Transfer Accuracy of Indirectly Bonded Orthodontic Braces With Different Transfer Trays

We'll reach out to this number within 24 hrs