search
Back to results

Ultrasound Comparison of Radial Artery Hyperplasia After Use of a 7F Sheathless Guide vs. 6F Sheath/Guide Combination (PRAGMATIC)

Primary Purpose

Coronary Artery Disease

Status
Completed
Phase
Not Applicable
Locations
Study Type
Interventional
Intervention
7F sheathless Guide Catheter
6F Sheath/Guide Catheter Combination
Sponsored by
Tallahassee Research Institute, Inc.
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional treatment trial for Coronary Artery Disease focused on measuring transradial percutaneous coronary intervention

Eligibility Criteria

18 Years - undefined (Adult, Older Adult)All SexesDoes not accept healthy volunteers

Inclusion Criteria:

  • Age 18 or above with coronary artery disease
  • Scheduled for transradial PCI

Exclusion Criteria:

  • Has had prior transradial access for heart catheterization or PCI in same radial artery as planned access site
  • Not willing to undergo follow-up ultrasound examinations
  • Acute ST elevation myocardial infarction or other emergent PCI
  • Inability to provide informed consent

Sites / Locations

    Arms of the Study

    Arm 1

    Arm 2

    Arm Type

    Experimental

    Placebo Comparator

    Arm Label

    7F Sheathless Guide Catheter

    6F Sheath/Guide Catheter Combination

    Arm Description

    Patients in this arm will undergo their percutaneous coronary intervention using a 7F Sheathless guide catheter

    Patients in this arm will undergo their percutaneous coronary intervention using a 6F Sheath/guide combination

    Outcomes

    Primary Outcome Measures

    Radial artery access site intimal-medial thickness (IMT)
    The incidence of other vascular complications such as radial artery occlusion, pseudo-aneurysms, radial artery diameter, and radial artery dissections will also be assessed.

    Secondary Outcome Measures

    Procedural Success Rate
    Procedural Success Rate (successful coronary stent implantation with < 30% residual stenosis and no other complications)
    Major Adverse Cardiac Events (MACE)
    In-hospital MACE (death, MI, urgent revascularization)
    Fluoroscopy Time
    Fluoroscopy Time
    Number of Guide Catheters Used
    Number of Guide Catheters Used during the procedure
    Frequency of Cross-over from Radial Access to Femoral Access
    Rate of Needing to Cross-over from Radial Access to Femoral Access

    Full Information

    First Posted
    August 23, 2017
    Last Updated
    August 31, 2017
    Sponsor
    Tallahassee Research Institute, Inc.
    Collaborators
    Boston Scientific Corporation
    search

    1. Study Identification

    Unique Protocol Identification Number
    NCT03271177
    Brief Title
    Ultrasound Comparison of Radial Artery Hyperplasia After Use of a 7F Sheathless Guide vs. 6F Sheath/Guide Combination
    Acronym
    PRAGMATIC
    Official Title
    The PRAGMATIC Study:A Prospective Randomized Clinical Trial Comparing Radial Artery Intimal Hyperplasia Resulting From a 7F Sheathless Guide (Mach 1TM) vs. a 6F Transradial Sheath/Guide Combination in Coronary Intervention
    Study Type
    Interventional

    2. Study Status

    Record Verification Date
    August 2017
    Overall Recruitment Status
    Completed
    Study Start Date
    February 25, 2016 (Actual)
    Primary Completion Date
    March 13, 2017 (Actual)
    Study Completion Date
    March 13, 2017 (Actual)

    3. Sponsor/Collaborators

    Responsible Party, by Official Title
    Sponsor
    Name of the Sponsor
    Tallahassee Research Institute, Inc.
    Collaborators
    Boston Scientific Corporation

    4. Oversight

    Studies a U.S. FDA-regulated Drug Product
    No
    Studies a U.S. FDA-regulated Device Product
    No
    Data Monitoring Committee
    No

    5. Study Description

    Brief Summary
    The purpose of this study is to determine if the routine use of a sheathless 7F guide catheter for transradial percutaneous coronary intervention (TR PCI) is non-inferior to a 6F sheath/guide combination with regards to radial artery injury (radial artery intimal-medial-adventitial thickening). To evaluate the radial artery, ultrahigh resolution ultrasonography (55 mHz) will be used to accurately quantify radial artery intimal-medial-adventitial thickness (IMT) at baseline and 90 days. A non-inferiority analysis will be performed to compare the degree of radial artery IMT at 90 days between the 7F sheathless guide approach and the 6F sheath/guide combination.
    Detailed Description
    The purpose of the PRAGMATIC study (A Prospective Randomized Trial comparing Radial Artery Intimal Hyperplasia resulting from a 7F Transradial Sheathless Guide [Mach 1] vs. a 6F Transradial Sheath/Guide Combination in Coronary Intervention) is 3 fold: (1) to determine if the routine use of a simple inexpensive "home-made" 7F sheathless guide catheter approach for TRA-PCI was associated with comparable degrees of radial artery access site injury and intimal-medial thickening (IMT) as the routine use of a 6F standard sheath/guide catheter combination; (2) to determine if the 7F sheathless approach was associated with comparable procedural success rates, procedure times, number of guides and crossover rates to a femoral approach compared to a 6F sheath/guide combination; and (3) to use ultrahigh resolution ultrasound to characterize the degree of RA injury and intimal-medial hyperplasia (IMT) that routinely occurs following transradial percutaneous coronary intervention. Materials and Methods Subjects and Study Design The study enrolled 41 consecutive patients undergoing elective non-emergent TRA-PCI at Tallahassee Memorial Hospital (TMH) from June 2016 to December 2016. The study protocol was approved by the TMH institutional review board. Informed consent was obtained prior to diagnostic coronary arteriography. Patients aged 21 years and over who were undergoing planned non-emergent PCI and willing to undergo a 24 hour and 90day post PCI RA ultrasound were eligible. Patients were excluded if they had undergone a prior ipsilateral TRA heart catheterization or PCI. There were no angiographic exclusions. Baseline clinical, demographic and angiographic characteristics were collected prospectively. Patients were randomly assigned to undergo TRA-PCI using a 7F sheathless Mach 1TM (Boston Scientific, Marlborough, MA) guide catheter or using our catheterization lab's standard 6F CordisTM (Johnson and Johnson, Inc.) sheath/6F Mach1TM guide combination. In order to minimize radial artery size bias, randomization was stratified according to patient sex. PCI with a drug-eluting stent was performed according to routine local practice and physician discretion. Patients were preferentially treated with a SYNERGYTM (Boston Scientific, Marlborough, MA) drug-eluting stent as the primary stent choice, however, other stents were allowed according to physician discretion. All patients received dual antiplatelet therapy (DAPT) prior to TRA-PCI with an oral aspirin (325 mg) and a p2Y12 platelet inhibitor (either 600mg clopidogrel or 180mg ticagrelor) bolus. Intravenous heparin was administered to achieve an activated clotting time (ACT) of at least 300 seconds. Immediately following TRA-PCI, the sheath and/or guide was removed and RA hemostasis was achieved using a standardized and previously validated patent hemostasis protocol that incorporates the Terumo TR Band Radial Compression DeviceTM. The technique used for the sheathless introduction of the 7F guide catheter was as follows: following diagnostic coronary angiography, a 6F 100 cm length multipurpose catheter (MP) was telescoped through the inner lumen of a 90 cm 7F Mach 1TM guide catheter. The MP was then used as an obturator to facilitate insertion of the 7F guide through the skin and into the RA arteriotomy site over a 0.035 J wire. Only after the 7F guide/6F MP combination was introduced into the RA and advanced together back to the aortic root, were the inner 6F MP catheter and 0.035 wire removed and the 7F guide engaged into the coronary ostium for TRA-PCI. Ultrahigh Resolution Ultrasound Assessment Using the FDA approved FUJIFILM VisualSonics 55 mHz probe and previously established methods,16,17 ultrahigh resolution duplex ultrasound of the RA access site was performed at 24 hours (pre-discharge) and 90 days post TRA-PCI. This technique has been well validated as a means to accurately depict and quantify the individual layers of muscular and elastic arteries. To prevent RA vasospasm, sublingual nitroglycerin (0.4 mg) was administered within 3-5 minutes prior to performing the ultrasound studies. M-mode, 2-dimensional and color doppler images were obtained. The RA diameter was recorded and then the individual borders of the layers of the artery delineated with M-mode ultrasound. To determine the mean IMT, we started off with the center of the probe centered over the RA puncture site and recorded the thickest IMT measurements noted just proximal to the site, at the center of the site (center of probe) and just distal to the site. We then repositioned the probe more proximally, placing its distal leading edge at the puncture site and obtained another proximal and mid probe measurement of IMT. The final recorded IMT was the average of these 5 measurements. Using this technique, we ensured sampling over an adequate length of the RA proximal to, at and slightly distal to the point of arterial access. The RA access site was also assessed for other signs of trauma, including small focal intimal tears, frank arterial dissections, pseudoaneurysms, arteriovenous fistulae, and vessel occlusion. Given high resolution imaging, we were forced to distinguish between limited focal intimal tears that were now easily visualized and simply a result of access site entry from more frank dissections. For this, we defined a limited access site intimal tear (LASIT) as a focal tear in the intima that was restricted to and not beyond the access site itself which did not encroach on the lumen or cause any flow abnormality. Tears or dissections beyond this were deemed true dissections. All studies and measurements were performed by 2 experienced vascular technicians who were blinded to treatment allocation with additional independent review by a reading physician who was also blinded to treatment allocation. Other Clinical Endpoints Assessed: Procedural success rates (successful implantation of the stent with residual stenosis of < 30% and no other complications), fluoroscopy time, the number of guide catheters used, and the frequency of cross-over from radial access to femoral access were also recorded. Routine clinical and interventional outcomes, including PCI success, in-hospital death, MI, coronary dissection, urgent revascularization were also prospectively collected. Ultrahigh frequency ultrasound parameters related Statistical Analysis For comparisons between groups, two-sided Student t-tests were used for continuous variables and chi-square or Fisher exact tests for discrete variables. The primary outcome of the study was a comparison of radial artery IMT thickness at 90 days between the 7F sheathless guide catheter group and the standard 6F sheath/guide combination group. The primary statistical analysis was based on a non-inferiority analysis and an intention to treat design. The null hypothesis was that the 7F sheathless Mach 1TM guide would be associated with at least a 0.08mm increase in IMT at 90 days compared with the 6F sheath/guide combination. A non-inferiority margin of 0.08 mm was selected as this represented a relatively small change compared to baseline IMT and RA diameter (~25% of baseline IMT and only ~3% of RA diameter). It was therefore deemed unlikely that this small difference would be clinically significant. Based on our own pilot data and a prior study, a standard deviation of 0.08mm was assumed for IMT measurements. Assuming a one-sided 95% confidence interval, at least 36 evaluated patients (~18 per group) were needed to have 90% power to detect if the lower limit of the one-sided confidence interval lies above the 0.08 limit. If the 95% confidence interval lies below this 0.08mm boundary, then the null hypothesis was to be rejected and non-inferiority declared. Superiority testing was also applied using a p<0.05 for a level of significance for intergroup comparisons.

    6. Conditions and Keywords

    Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
    Coronary Artery Disease
    Keywords
    transradial percutaneous coronary intervention

    7. Study Design

    Primary Purpose
    Treatment
    Study Phase
    Not Applicable
    Interventional Study Model
    Parallel Assignment
    Masking
    None (Open Label)
    Allocation
    Randomized
    Enrollment
    41 (Actual)

    8. Arms, Groups, and Interventions

    Arm Title
    7F Sheathless Guide Catheter
    Arm Type
    Experimental
    Arm Description
    Patients in this arm will undergo their percutaneous coronary intervention using a 7F Sheathless guide catheter
    Arm Title
    6F Sheath/Guide Catheter Combination
    Arm Type
    Placebo Comparator
    Arm Description
    Patients in this arm will undergo their percutaneous coronary intervention using a 6F Sheath/guide combination
    Intervention Type
    Device
    Intervention Name(s)
    7F sheathless Guide Catheter
    Intervention Description
    Transradial PCI will be performed with a 7F sheathless Guide Catheter
    Intervention Type
    Device
    Intervention Name(s)
    6F Sheath/Guide Catheter Combination
    Intervention Description
    Transradial PCI will be performed with a 6F Sheath/Guide Catheter Combination
    Primary Outcome Measure Information:
    Title
    Radial artery access site intimal-medial thickness (IMT)
    Description
    The incidence of other vascular complications such as radial artery occlusion, pseudo-aneurysms, radial artery diameter, and radial artery dissections will also be assessed.
    Time Frame
    90-day
    Secondary Outcome Measure Information:
    Title
    Procedural Success Rate
    Description
    Procedural Success Rate (successful coronary stent implantation with < 30% residual stenosis and no other complications)
    Time Frame
    up to 24 hours
    Title
    Major Adverse Cardiac Events (MACE)
    Description
    In-hospital MACE (death, MI, urgent revascularization)
    Time Frame
    from date of PCI until date of death, MI or urgent revascularization, whichever came first, assessed up to 72 hrs
    Title
    Fluoroscopy Time
    Description
    Fluoroscopy Time
    Time Frame
    During PCI procedure (from beginning of procedure until end)
    Title
    Number of Guide Catheters Used
    Description
    Number of Guide Catheters Used during the procedure
    Time Frame
    During PCI procedure (from beginning of procedure until end)
    Title
    Frequency of Cross-over from Radial Access to Femoral Access
    Description
    Rate of Needing to Cross-over from Radial Access to Femoral Access
    Time Frame
    During PCI procedure (from beginning of procedure until end)

    10. Eligibility

    Sex
    All
    Minimum Age & Unit of Time
    18 Years
    Accepts Healthy Volunteers
    No
    Eligibility Criteria
    Inclusion Criteria: Age 18 or above with coronary artery disease Scheduled for transradial PCI Exclusion Criteria: Has had prior transradial access for heart catheterization or PCI in same radial artery as planned access site Not willing to undergo follow-up ultrasound examinations Acute ST elevation myocardial infarction or other emergent PCI Inability to provide informed consent
    Overall Study Officials:
    First Name & Middle Initial & Last Name & Degree
    Wayne B Batchelor, MD, MHS
    Organizational Affiliation
    Tallahassee Research Institute
    Official's Role
    Principal Investigator

    12. IPD Sharing Statement

    Plan to Share IPD
    No

    Learn more about this trial

    Ultrasound Comparison of Radial Artery Hyperplasia After Use of a 7F Sheathless Guide vs. 6F Sheath/Guide Combination

    We'll reach out to this number within 24 hrs