search

Active clinical trials for "Adenoma"

Results 441-450 of 652

Localization of Parathyroid Adenoma by Fluorocholine PET/MRI (Positron Emission Tomography -MRI)...

Primary Hyperthyroidism

A comparative prospective study to evaluate different imaging modalities (pet-ct and pet-mr) prior to surgery in parathyroid tumor patients.

Unknown status10 enrollment criteria

The Use of Cap-assisted Forward Viewing Endoscopy for Examination of the Ampulla of Vater

Ampulla of Vater Intestinal-Type Adenoma

The aim of this study is to compare the visualization rates of the ampulla of Vater using forward- viewing endoscopes with or without cap attached to the distal end in the same patient.

Unknown status6 enrollment criteria

The Impact of Split Dose of Low-volume Polyethylene Glycol on Adenoma Detection Rate

Colonic Adenomas

An adequate level of bowel preparation is crucial for the efficacy and safety of colonoscopy. Strong evidences suggest that bowel-preparation quality shows an inverse correlation with length of the interval between the end of cleansing agent intake and the start of colonoscopy (shorter intervals are associated with better preparation levels). Accordingly, the use of a split-dose administration regimen has been demonstrated to significantly improve the quality of preparation, besides patient acceptability, as compared with standard administration the day before colonoscopy. All randomized controlled trials comparing split versus standard preparations were primarily aimed at assessing the quality of colon cleansing, by means of either validated or not-validated colon cleansing scales. The impact of a split dose regimen on objective colonoscopy performance measures such as adenoma detection rate (ADR) has never been specifically and prospectively evaluated. The present study is aimed at evaluating whether the split-dose preparation regimen is associated with an increase of adenoma detection. For this purpose, asymptomatic subjects aged 50-69, undergoing screening colonoscopy for positive immunologic fecal occult blood test are randomized in a 1:1 ratio to receive low-volume (2L) PEG plus ascorbic acid solution either in a split-dose (study arm) or in a full-dose regimen (control arm). Treatments are allocated using a computer-generated, randomized code list. The treatment allocation is concealed and is accomplished at the screening visit through non-research personnel who is not involved in the study. To ensure masking, the endoscopists who perform the colonoscopies are not involved in the randomization process and in the pre-procedure data collection. In this study the the primary outcome measure was the proportion of patients with at least one adenoma (Adenoma Detection Rate) in each harm. Data on bowel cleansing, patient compliance, tolerability and acceptability were also collected. A sample size of at least 514 patients (257 in each arm) was calculated, by hypothesizing a relative increase of 25% in the adenoma detection rate in the split dose preparation group, assuming a 40% prevalence of one or more adenoma in FIT-positive patients undergoing screening colonoscopy (significance level 0.05, 90% power).

Unknown status13 enrollment criteria

Evaluation of Endorings-2-assisted Colonoscopy: a New Accessory for Improvement of Adenoma Detection...

Colonic AdenomaColonic Polyp2 more

Screening colonoscopy for colorectal cancer is essential to diagnose and remove adenomas, precancerous stages of colorectal cancer. Unfortunately approximately 25 % of all adenomas are missed during the examination. Recently a new colonoscopy accessory, the Endorings-2 (EndoAid Ltd., Casearea, Israel), has been designed to improved the detection of adenomas during colonoscopy (adenoma detection rate). Endorings-2 is a silicone-rubber device that is fitted on the colonoscope and is equipped with circular flexible silicon rings mechanically stretching the colonic folds during withdrawal. This study aims to evaluate the efficacy of Endorings-2 to improve the adenoma detection rate in a prospective, blinded clinical trial. 292 patients with an indication for a screening colonoscopy shall be included (1:1 randomization in standard colonoscopy versus Endorings-2-assisted colonoscopy).

Unknown status9 enrollment criteria

Detection of Functioning Pituitary Microadenoma: PET/MRI Versus PET/CT

Pituitary Adenoma

This is a prospective case-control study to compare the usefulness of 18F-FDG PET/MRI with that of 18F-FDG PET/CT in detection of functioning pituitary microadenomas.A single dose of 370 Mega-Becquerel (MBq) 18F-FDG will be injected intravenously.Visual and semiquantitative method will be used to assess the PET/MRI and PET/CT images.

Unknown status2 enrollment criteria

MRA and ARB Treatment in Screening of Primary Aldosteronism

Primary Aldosteronism Due to Aldosterone Producing Adenoma

Current guidelines recommend withdrawal of treatments that affect the aldosterone/renin ratio (ARR) when screening for primary aldosteronism (PA). However, abandonment of mineralocorti-coid-receptor antagonist (MRA) and/or blockers of the renin-angiotensin system can deteriorate control of blood pressure (BP) and hypokalemia. Thus, in consecutive patients with an unambiguous diagnosis of PA in wash-out from confounding treatments and subtyped by AVS, the investigators have compared within-patient the plasma aldosterone and active renin concentration, and the ARR values, measured at baseline, and after a one-month treatment with MRA alone and combined with an AT-1 receptor blocker (ARB). Patients on a regular salt intake have been treated with canrenone (50-100 mg orally) for 1 month, after which olmesartan (10 or 20 mg orally) has been added for another month with up-titration of both treatments over the first 2 weeks to control BP and hypokalemia, however maintaining background therapy. The biochemical variables and the ARR have been assessed in an identical manner at baseline values and after each month of treatment. The investigators calculated that with a sample size of 40 patients the study will have a 95% power to show a clinically significant 20% change in the ARR at an 5% alfa-value using a two-sided paired t-test. Hence, this study will allow to determine if an MRA alone, or added to an ARB at doses that control BP and hypokalemia, affect or not the ARR, thus allow to establish if these agents can be administered or must be forbidden during the screening of PA.

Completed5 enrollment criteria

Ambient Lighting During Colonoscopy and Its Effect on Adenoma Detection Rate and Eye Fatigue

Colorectal Cancer ScreeningColon Adenomatous Polyp

A retrospective and prospective study to determine if the use of ambient lighting during screening colonoscopy is well tolerated and if ambient lighting will help physicians maintain adenoma detection rates while decreasing symptoms of eye strain as the day progresses.

Completed9 enrollment criteria

Anthocyanin Extract and Phospholipid Curcumin in Colorectal Adenoma

Colorectal AdenomaRisk Reduction

Colonic adenomatous polyps are pre cancer lesions and are used as intermediate markers for testing agents with potential cancer prevention. Meriva© is a bioavailable form of curcumin, a polyphenolic compound obtained from turmeric (Curcuma longa L.) endowed with anti-inflammatory, antioxidant and antitumor effects. In vivo data indicate that curcumin formulated with phosphatidylcholine furnishes higher blood levels of parent agent than natural curcumin. Mirtoselect©, an anthocyanin mixture from bilberry containing isolated cyanidin-3-glucoside (C3G), the most abundant anthocyanin in diet, prevents intestinal adenoma formation in the Apc(Min) mouse model. The investigators hypothesize that the combination of both agents will decrease the expression of proteins involved in colon tumorigenesis relative to placebo. The change of biomarker expression between pre-treatment biopsy and post-treatment endoscopic resection in the target adenoma and the normal rectal mucosa will be the response measures. The primary response measure is the change of immunohistochemical (IHC) expression of β-catenin in adenomatous tissue and normal rectal mucosa. Secondary response measures are the changes of IHC Nuclear Factor-Kβ (NFKβ), cell proliferation by Ki-67 Labeling Index and apoptosis by P53 in adenomatous and adjacent normal mucosa. The study design is a phase II, randomized, double blind, placebo controlled, window of opportunity trial of the combination of Mirtoselect 1 gr/day+Meriva 1 gr/day or placebo. Subjects with histological confirmation of colorectal adenomatous polyps >1 cm not suitable to immediate complete removal will be enrolled in a 4-week intervention trial before endoscopic polypectomy. The demonstration of a biological activity of the two agent combination may provide the rationale for a phase III trial aimed at reducing the risk of colon cancer in high risk subjects.

Unknown status6 enrollment criteria

Effectiveness of Instillation of Blue Water (Indigo Carmin®) for Colonoscopy

Adenoma Detection to Prevent Colorectal Cancer

The colonoscopy is the reference examination for the diagnosis of neoplastic lesions in the colon and rectum. Mass screening assessment studies have shown that colonoscopic detection and removal of adenomas in patients selected through fecal occult blood test reduces colorectal cancer incidence and mortality. However, the literature has reported interval cancer cases or adenomas, probably "missed" by the colonoscopy. In theory, using coloured warm water could improve colon preparation by mobilizing the residual faeces, decreasing the colic spasm and increasing the visualization of the pit pattern. Preliminary American studies, led by Leung et al, have shown a very clear increase in the adenoma detection rate. The investigators' study involves 1 000 patients, treated in the Rhône-Alpes / Auvergne region. The patients present an indication for colonoscopy following a positive fecal occult blood test or symptoms or personal and family histories of pre-cancerous colonic lesions. They will be randomized into two study groups:one of both groups of study: Group 1: patients undergoing a colonoscopy wtih instillation of tepid water tinged with blue (Indigo Carmin®) Group 2: patients undergoing a standard colonoscopy with insufflation of air. The main objective is to show that the colonoscopy with blue water (Indigo Carmin®) enable detection of more lesions than standard colonoscopy with insufflation of air. The two techniques will be also compared in terms of tolerance, of duration of colonoscopy and type of detected lesions. In case of improved detection of colorectal lesions, the blue water instillation technique of could dramatically change gastroenterologists' practice by becoming the reference method. The expected clinical benefits are potential revealing of more neoplastic lesions and improvement in abdominal discomfort after colonoscopy.

Unknown status20 enrollment criteria

Study of Calcium Plus Vitamin D Supplementation in Prevention of Colorectal Adenomas Recurrence...

Colorectal Adenoma

Calcium plus vitamin D may be effective in the prevention of colorectal adenoma recurrence. The aim of this study is to investigate the effect of supplementation with calcium plus vitamin D on the recurrence of colorectal adenomas.

Unknown status16 enrollment criteria
1...444546...66

Need Help? Contact our team!


We'll reach out to this number within 24 hrs