search

Active clinical trials for "Hypoxia"

Results 821-830 of 998

Evaluation of SpO2 Measurement Using a Smartwatch

HypoxiaHypercapnia

The aim of the study is to compare the measurement of peripheral blood oxygen saturation using a smartwatch with a medical-grade pulse oximeter.

Completed7 enrollment criteria

Correlation Between Lung UltraSound Score and Hypoxemia for Interstitial Syndrome in Emergency Department...

Interstitial Lung Disease

The primary objective of this study is to assess the presence of a correlation between the Lung ultrasound score (LUSS) and PaO2/FiO2 in patient presenting with interstitial syndrome (IS) in the ED. The primary end point considers the null hypothesis to be a negative linear distribution for LUSS and PaO2/FiO2 values. Secondary objectives and secondary end points One of the secondary objectives is to assess the correlation between the LUSS and PaCO2 in patient presenting with IS in the ED. The end point of this secondary outcome considers the null hypothesis to be a positive linear distribution for the LUSS and PaCO2 values. Another secondary objective is to determine the influence of the presence of unilateral or bilateral pleural effusion on the correlation between LUSS and PaO2/FiO2. The end point of this secondary outcome considers the null hypothesis to be a negative linear distribution for LUSS and PaO2/FiO in those three sub-groups: absence of pleural effusion group, unilateral pleural effusion group and bilateral pleural effusion group.

Completed7 enrollment criteria

Evaluation of RDS MultiSense® in Desaturation Analysis in Healthy Volunteers

Hypoxia

In this clinical study, the investigators will compare vital parameters measurements obtained using continuous data from reference monitors and continuous wireless MultiSense® monitoring patch in 30 healthy volunteers under induced and controlled hypoxia.

Completed15 enrollment criteria

Hypoxia-altitude Testing to Predict Altitude Related Adverse Health Effects in Chronic Obstructive...

Hypoxia Altitude Simulation TestHigh Altitude

The predictive value of the hypoxia altitude simulation test (HAST) or other baseline values to predict altitude-related adverse health effects (ARAHE) is not established. To address this gap, the main goals of this investigation will be 1) to evaluate the diagnostic accuracy of the HAST in identifying individuals that will experience ARAHE during altitude travel and 2) to establish prediction models incorporating other commonly assessed clinical characteristics either alone or in combination with the HAST as predictors of ARAHE in altitude travelers. Hypotheses: In lowlanders with COPD, a PaO2 <6.6 kPa or another cutoff of PaO2 or SpO2 at the end of the HAST, at rest or during exertion and/or clinical variables including symptoms, pulmonary function indices, 6-min walk distance (6MWD), either alone or combined to a multivariable model, will predict ARAHE during a sojourn of 2 days at 3100m with accuracy greater than chance

Completed5 enrollment criteria

Multicentric Evaluation of the Impact on Hypoxia Sensitivity of Patients With COVID-19

Covid19SARS-CoV2 Infection2 more

In this study, the investigators will examine the extent to which having suffered coronavirus disease 2019 (COVID19) impacts one's sensibility to hypoxia by means of the 'Richalet test'. The aim of the study is to formulate recommendations for advice in altitude mountain medicine for patients having suffered COVID19. To determine any eventual changes in response to hypoxia, performances by participants having suffered COVID-19 and participants having stayed free of COVID-19 will be both compared intra-individually with previous performances (pre-COVID-19 pandemic) and between both groups of subjects. The investigators hypothesize that patients having suffered COVID19 might perform differently on the cardiopulmonary exercise test compared to before the illness. Based on recent research on COVID19 pathophysiology and -patient follow-up, it might be expected that COVID19 alters the response to hypoxia, thus influencing one's acclimatization capabilities at high altitude, albeit reversibly and/or temporarily. Different alterations of response to hypoxia could be observed. The virus causing COVID19, the "severe acute respiratory syndrome coronavirus 2" (SARS-CoV-2), has the potential to significantly damage the nervous system and to affect cardiorespiratory functions. If SARS-CoV-2 does, similarly to MERS and SARS, induce cardiorespiratory and neurological dysfunction, then COVID19 patients may have impaired hypoxia response after infection and perform worse on the 'Richalet test' in comparison to before the illness. Conversely, reports of high prevalence of dyspnea in patients up to 3 months after SARS-CoV-2 infection, might indicate infection-induced degenerative changes in the carotid bodies, which might lead to sensibilization of the peripheral chemoreceptors to impaired oxygenation. Possibly similar to the impact of aging and smoking on the cardiorespiratory response to hypoxia, this phenomenon of sensibilization could entail an increased hypoxic response in patients having suffered COVID-19. Accordingly, patients might perform better on the 'Richalet test' post-COVID-19 than they did before.

Unknown status15 enrollment criteria

Owlet Smart Sock 3 Accuracy on Infants

Hypoxia Neonatal

The purpose of this research study is to evaluate the Owlet Smart Sock 3 wireless pulse oximeter performance in assessing the heart rate and oxygen saturation in neonatal population, while measuring the same parameter with a standard wired pulse oximeter simultaneously. The monitoring duration with the study device will be a maximum of 60 minutes, after which the recorded data from the Owlet Smart Sock 3 and the standard wired pulse oximeters will be de-identified and analyzed.

Completed6 enrollment criteria

The Effect of Hypoxic and Normoxic Cerebral Oximetry Levels on Cognitive Functions After Carotid...

Cerebral HypoxiaCarotid Stenosis1 more

In this study, we investigated the effect of the capacity to cope with oxidative stress (oxidative stress response during and after clamping) in individuals with cerebral oximetry level between 40- 60 % and above 60 % and their effect on cognitive functions. Methods: In this retrospective study, patients who were scheduled for carotid endarterectomy, examined the MOCA tests before and after the operation and collected blood samples intraoperatively were included between January 2020-2021. The time periods specified below, blood samples were taken and serums were frozen at -80 celcius all this patients. Montreal cognitive function assessment test was applied before the operation, 24 hours and 7 days after the operation. Ten mililiters venous blood samples were collected to examine the status of basal neuron specific enolase, S100B, oxydative stress parameters (HAF-1 and DAF-1) at time intervals. Time intervals as follow: T1: Peripheral baseline measurements (blood will be taken from arterial blood sampling) + Cerebral Oxymeter levels + Montreal cognitive performance test + Modified Rankin Scale (mRS) T2: 1 minute before clamping (from peripheral and jugular vena blood sampling) + Cerebral Oxymeter levels T3: Before opening clamp(from peripheral and jugular vena blood sampling) + Cerebral Oxymeter levels T4: 24 hours after the procedure. (peripheral blood sampling) + Montreal cognitive performance test T5: 7 days after the operation. (peripheral blood sampling) + Montreal cognitive performance test + CO levels+ Modified Rankin Scale (mRS) Results: We found significantly positive corelation between cerebral oxymeter levels, oxydative stress parameters and cognitive performance tests in this six patient.

Completed17 enrollment criteria

Awake Prone Positioning for COVID-19 Acute Hypoxaemic Respiratory Failure

SurvivalProsthesis1 more

The objective of our study is to evaluate the effectiveness of prone position in preventing intubation or death in spontaneously ventilated patients with COVID-19 with acute respiratory failure.

Completed5 enrollment criteria

Accuracy of Pulse Oximeters With Profound Hypoxia

SpO2

This project aims to test the accuracy of pulse oximeters during mild, moderate, and severe hypoxia, i.e., a range of arterial HbO2 saturation from 100 down to 70%. A typical study will include at least ten subjects (at least 200 necessary data points to meet the ISO 80601-2-61:2017).

Completed9 enrollment criteria

Effect of an H1 Receptor Antagonist on Exercise Performance in Hypoxia

HypoxiaAltitude

This study seeks to determine whether a simple, single intervention of Cetirizine / Zyrtec® use can improve exercise performance of active individuals when acutely exposed to altitude. For this project, healthy subjects will perform steady state and progressive work rate exercise, endurance performance time trials, and repeated sprint performance time trials in the laboratory at a simulated altitude of 3000m (9900ft) after dosing with 10 mg of Cetirizine or a placebo in a repeated measures design.

Completed12 enrollment criteria
1...828384...100

Need Help? Contact our team!


We'll reach out to this number within 24 hrs