Development of Ultra-Low Dose CT Based Screening for Aortic Aneurysms
Aortic AneurysmThoracic2 moreThe primary objective of this research project is development and validation of a new, non-contrast gated aortic (NCGA) computer tomography scan algorithm for screening of aortic aneurysm in the chest and abdomen in at risk patients. This study would initially be performed in patients with a known aneurysm and done in addition to their indicated surveillance CT scan.
The CardiOvascular Remodeling Following Endovascular Aortic Repair (CORE) Study
Thoracic Aortic AneurysmThe use of TEVAR is increasing rapidly and patients even in younger patients. However, current endografts are several orders of magnitude stiffer than the native aorta. Pre-clinical and clinical studies have reported acute aortic stiffening after TEVAR resulting in hypertension, elevated pulse pressure, cardiac remodeling, reduced coronary perfusion, and finally, heart failure. These effects are markedly profound in young patients, as their hearts and aortas are more compliant. Previous studies on adverse cardiovascular remodeling have important limitations, such as retrospective design, use of echocardiography (with low reproducibility and high operator-dependency), and mixed populations. A systematic assessment of the deleterious effects of TEVAR is still missing. The objective of this study is to perform a prospective, non-randomized controlled, study in which blood pressure, heart rate, ECG, echocardiography, CT, MRI, intra-luminal hemodynamic assessment, computational modeling and biomarkers are used to assess cardiovascular remodeling following TEVAR. This study targets patients with thoracic aortic aneurysms (TAA) or penetrating aortic ulcers (PAU) treated with TEVAR. A control group will consist of TAA and PAU subjects who do not require endovascular treatment. The specific aims of the study include: 1) Quantification of cardiovascular remodeling following TEVAR in TAA or PAU patients. 2) Validation of computational modeling of thoracic aortic hemodynamics following TEVAR using the above clinical measurements. Once validated, computational analyses will be performed to virtually assess the impact of more compliant endografts on cardiac and aortic hemodynamics. 3) Investigation of diagnostic accuracy of ECG, BNP, NT-pro-BNP and Troponin T, for cardiac remodeling compared to MRI, the reference method. This study will assess the impact of thoracic aortic stent grafts on the cardiovascular system through non-invasive measurements. Although there are no direct benefits for the enrolled subjects, future aortic patients might benefit from better patient management with improved aortic endograft designs and long-term outcomes.
Effects of Exercise on Thoracic Aneurysms
Thoracic Aortic AneurysmThoracic aneurysm incidence is estimated to 4.5 cases per 100 000. The manifestation as well as natural history of thoracic aneurysm depend on many factors such as its localisation, its diameter, presence of collagen disease and family history. For the ascendant aortic aneurysm, it is often linked to a degeneration of the media arterial layer of the arterial wall. The media degeneration is cause by the degeneration of the elastic fibres, which lead to a weakening of the arterial wall accompanied with dilation. This process is often due to age and is accelerated by high blood pressure. Amongst the numerous factors causing the aneurysm, the investigators find: hypertension, aortic bicuspid valve, smoking, atherosclerosis, trauma and genetic predisposition. The average growth rate of thoracic aneurysm is 0.1-0.2 cm/year. The risk of rupture is associated to the size of the aneurysm as well as patient's symptoms. The ruptures and dissections rates are accounted for 2-3/year for thoracic aneurysm between 5.5-6.0 cm in diameter. The patients are often limited in their daily life activities considering their concern and risk of rupture and/or dissect. The effects of exercise on the progression of the aneurysm dilation in patients with thoracic ascendant aortic aneurysm are unknown. It is well known that high blood pressure is a risk factor for rupture of the aortic aneurysm. Many studies have demonstrated the benefits of physical exercise regarding the lowering impact of blood pressure in a cardiac hypertensive population. At 3 and 6 months of the intervention, the subjects in the exercise group will have: 1) a lowered blood pressure at rest and during exercise, 2) maintenance/ improvement of muscle strength, 3) improvement of aerobic exercise capacity (VO2max), and 4) aortic dilation that remained stable or comparable to the control group. The research objective is to measure and compare to a control group, the effects of an exercise program on the following parameters: blood pressure response at rest and during exercise, as well as the VO2max at 3 and 6 months time of the intervention. This randomised and prospective study will take place at the " Institut Universitaire de Cardiologie et de Pneumologie du Québec (IUCPQ) " and will include patients who have a non-surgical ascendant thoracic aortic aneurysm (ATAA). The selected subjects will be randomised into two groups: 1) exercise group (n=15), and 2) control group (n=15). Both groups will be met prior to the intervention (baseline) and at 3 and 6 months time of the intervention, and measures described below will be recorded.
Guo's Visceral Arteries Reconstruction: First in Man Study
Thoracoabdominal Aortic AneurysmsA First in man study to evaluate the safety and efficacy of thoracoabdominal aortic stent system for endovascular treatment of thoracoabdominal aortic aneurysms.
ENTRUST - TAArget® Thoracic Stent Graft Clinical Trial
Thoracic Aortic AneurysmEvaluate the safety and effectiveness of endovascular repair with the LeMaitre TAArget thoracic stent graft as an alternative to open surgical repair.
Immunonutrition and Thoracoabdominal Aorta Aneurysm Repair
Thoracic Aortic AneurysmRespiratory InsufficiencyThe purpose of this study is to determine whether immunonutrition and pre operative nutrition can reduce lenght of respirator support, lenght of stay in the ICU and incidence of post operative infections
Clinical Study of Thoracic Aortic Aneurysm Exclusion
Thoracic Aortic AneurysmThe Valiant stent-graft system is a flexible, implantable vascular stent-graft endoluminal device preloaded in a delivery system that is used to exclude thoracic aortic lesions (thoracic aneurysms, thoracic dissections, penetrating ulcers, traumatic transections and both traumatic and degenerative pseudoaneurysms.
Effectiveness of Acetazolamide in Reducing Paralysis of the Leg in Patients Undergoing Aortic Aneurysm...
Thoracic AneurysmThe aorta is a large vessel that carries blood away from the heart. Sometimes it becomes dilated (swells) and this is known as 'aneurysm'. It may cause either dissection (splitting of the wall) or rupture (bursting). Treatments could be through open surgery or by use of stents (tubular mesh) through the groin. There is a risk of causing paraplegia, which is the loss/weakness of leg function as well as incontinence (loss of bladder and/or bowel control). To try and prevent this, a number of techniques are used such as removing/draining of cerebrospinal fluid (CSF) (the clear fluid surrounding the brain and spinal cord). Sometimes however; CSF cannot be drained drain cannot be inserted draining is unlikely to improve the situation Paralysis/weakness of the leg is seen In these situations, the use of a drug called acetazolamide may be helpful. This reduces the production of CSF and therefore decreases the need for CSF draining. It may also have an effect in decreasing the risk of paraplegia. Patients will be randomly (by chance) placed into one of two groups. One will get the drug as tablets and injection and the other will not receive any acetazolamide at all. Blood tests will be done in both groups. We expect to have 100 patients in the study, with patient involvement for a total of 10 days (maximum).
Safety and Efficacy of Multiple Overlapping Uncovered Stents for Pararenal Aortic Aneurysm Repair...
Aortic AneurysmAortic Aneurysm5 moreComplex aortic aneurysms involving major branches have been difficult endovascularly. The primary purposes of this study is to evaluate the safety, feasibility, and efficacy of multiple overlapping uncovered stents in treating aortic aneurysm while preserving major visceral branches, including the celiac artery (CA), superior mesenteric artery (SMA) and renal artery (RA).
Comparison of Carbon Dioxide and Saline Flush to Saline Flush in TEVAR and TAVI Procedures to Reduce...
Thoracic Aortic AneurysmAortic Stenosis Symptomatic2 moreThoracic endovascular repair (TEVAR) and transcatheter aortic valve implantation (TAVI) are standard of care procedures to treat thoracic aortic aneurysm or severe aortic stenosis, respectively. Both procedures have a high risk of stroke and silent infarction. Gas has been detected in the cerebral vasculature during these procedures and associated with DWI positive lesions on MRI. The hypothesis is that air emboli contribute to stroke and silent infarction. The investigators propose addressing air emboli by flushing the device with carbon dioxide prior to flushing with saline. This is a pilot study comparing standard saline flush alone to carbon dioxide flushing with saline flush.