Neck Evolution With Ovation in Spain
Abdominal Aortic AneurysmThis is a multicenter, observational, prospective, single arm registry using Ovation Alto Endograft. A minimum of 50 up to a maximum of 120 subjects undergoing endovascular repair with Ovation Alto endograft will be enrolled and followed procedurally to discharge, at 1month, 6 months, 1 year and yearly afterward up to 3 years. This registry of Ovation Alto endograft will provide further assessment to confirm continuing safety and effectiveness of the graft and to confirm the stability of the neck diameter over time when treated with this device.
Thoraflex Hybrid and Relay Extension Post-Approval Study
Thoracic DiseasesAortic Aneurysm3 moreThe goal of this observational study is to evaluate the Thoraflex Hybrid device alone and in combination with the RelayPro NBS stent-graft in the treatment of aortic disease affecting the aortic arch and descending aorta with or without involvement of the ascending aorta. Patients who undergo treatment with the Thoraflex Hybrid device with or without extension with a RelayPro NBS stent-graft will be eligible for enrolment and study activities and follow-up regime will follow standard care at each participating site. Participant involvement in the study will last for a total of 10 years from the point at which the Thoraflex Hybrid device is placed.
Evaluation of the Impact of Prehabilitation on Recovery Following Open Surgery for Abdominal Aortic...
Abdominal Aortic AneurysmThis is a pilot, prospective, randomized control trial that aim to provide a first estimation of the 3-month post-operative variation in the functional recovery of patients who benefited from an outpatient pre-habilitation program and patients who did not benefit from it.
JAGUAR Trial (Outside United States; OUS): ObJective Analysis to GaUge EVAR Outcomes Through Randomization...
AAAAAA - Abdominal Aortic AneurysmProspective, randomized, multi-center study designed to evaluate the outcomes of commercially available contemporary EVAR in a real-world population. Patients will be randomized into two device cohorts and compared across the primary endpoints. Patients will be followed procedurally to discharge, at 1, 6, 12 months and annually through to 5 years (total follow-up commitment).
Modified Preloaded System for Renal Arteries in Fenestrated Endografting (MPSRA)
Juxtarenal Aortic AneurysmThoracoabdominal Aortic Aneurysm7 moreAdvanced Endovascular repair of aneurysms and dissections involving thoraco-abdominal (type I-IV) and complex abdominal (juxta and para-renal) aorta is a ground-gaining procedure allowing favorable results in high surgical risk patients. The availability of iliac vessels navigation and the major role of lower leg perfusion in order to decrease the risk of spinal cord ischemia during these complex procedures, led to the development of devices with lower sheaths sizes and to the improvement of the technique with preloaded devices for visceral vessels in order to navigate in hostile anatomies or when an iliac access is not available. The aim of the study is to evaluate in a prospective single center observational setting, the outcomes, safety and efficacy of the modified preloaded system for renal arteries in fenestrated endografting in the routine treatment of paravisceral and thoraco-abdominal aortic pathologies.
AAA-SHAPE Pivotal Trial: Abdominal Aortic Aneurysm Sac Healing and Prevention of Expansion
Aortic AneurysmAbdominalTo determine the safety and effectiveness of IMPEDE-FX RapidFill to increase the percentage of subjects with shrinkage of the abdominal aortic aneurysm sac when used as an adjunct to on-label endovascular aneurysm repair (EVAR) stent graft treatment in trial subjects considered candidates for elective EVAR.
Nectero EAST System Clinical Study
Abdominal Aortic AneurysmThe purpose of this randomized clinical trial is to treat patients with small to mid-sized abdominal aortic aneurysms (AAA), maximum diameter of 3.5 cm to 5.0 cm, using a locally delivered, single-dose endovascular treatment. The main question the study aims to answer is to demonstrate efficacy of the product for stabilization of these small to mid-sized AAA.The study will compare the treatment group to the typical standard of care for these patients, surveillance. All subjects will be followed at designated intervals at 6, 12, 18 and 24 months with continued follow-up annually for up to 5 years.
Patient Specific Biomechanical Modeling of Abdominal Aortic Aneurysm to Improve Aortic Endovascular...
Aortic AneurysmThis project is aiming at the integration of a biomechanical computer program with a guidance code to simulate the endovascular repair (EVAR) procedure of abdominal aortic aneurysm (AAA). The computational time associated with finite element simulation generally renders its usage impractical for real-time application. Based on data collected during clinical interventions and a priori knowledge of AAA and endovascular device mechanical modeling, the investigators are proposing a deformable registration between preoperative CT-scans and per-operative fluoroscopy that will take into account prior simulations of participant specific EVAR procedures. To avoid the computational cost of a full finite element simulation, the investigators propose a simplified and real-time compliant repetitive mechanical behaviour based on participant specific parameters. The results of this research will provide the Canadian industry with the first realistic deformable vascular geometry tool for live endovascular intervention guidance. The proposed biomechanical modeling can be translated to other vascular intervention procedure by adjusting the biomechanical parameters.
Treatment in Thoracic Aortic Aneurysm: Surgery vs Surveillance
Ascending Aortic Aneurysm EnlargementAscending Aorta AneurysmThe ascending aorta conducts blood from the heart to the rest of the body. The ascending aorta can become enlarged, and the risk of tearing and rupturing becomes higher with larger aorta. When the ascending aorta tears or ruptures, the risk dying is high even if surgery is done as soon as possible. Traditionally, when the ascending aorta gets above 5.5 cm, surgery is recommended to replace the aorta. However, this threshold is based relatively weak evidence, and sometimes patients with smaller aorta can tear or rupture. On the other hand, surgery carries its own risk as well. Since there are risk of waiting or doing surgery, there is currently no great support for either approach for patients with a smaller aorta. In the TITAN SvS trial, patients with an ascending aorta between 5.0 to 5.5 cm is assigned by chance to the early surgery group, in which they will undergo replacement of aorta, or the surveillance group, in which they will be closely monitored. The chance of dying or suffer tearing or rupture of aorta between the two groups will be compared. The result of the trial will guide future practice for patients with enlarged ascending aorta. This is a prospective, multi-centre randomized control trial that compares the all-cause mortality, aneurysm-related aortic events, rate of stroke, and quality of life for those patients undergoing early elective ascending aortic surgery to those patients undergoing surveillance. Patients referred for an ascending aortic aneurysm that meets the inclusion criteria will be randomized to the early elective surgery group or the surveillance group. Recruitment will end when the desired sample size is reached, and the patients will be followed for a minimum 2-year period. The primary objective of the trial is to compare the composite outcome of the all-cause mortality and incidence of acute aortic events between surveillance and elective ascending aortic surgery for patients with degenerative or bicuspid valve-related ascending aortic aneurysm after 2 years of follow up. The hypothesis is that the early surgery group will have a significantly lower all-cause mortality and incidence of acute aortic events at 2 years of follow up compare to the surveillance group. The result of this trial will provide evidence based guidance in the appropriate management of ascending aortic aneurysm based on the size criteria, and establish a large database for future investigations.
A PMCF Study in Patients With Acute or Chronic Aortic Dissection or Aortic Aneurysm Treated With...
Vascular AneurysmThe NEOS post-market clinical follow-up study is undertaken to demonstrate the safety and clinical performance of E-vita OPEN NEO in the treatment of aneurysm or dissection in the ascending aorta, aortic arch and descending thoracic aorta.