MRI in Transcatheter Aortic Valve Replacement Patients
Aortic Valve StenosisThe hypothesis is that SEV result in superior valvular hemodynamics (more pronounced during exercise) and exercise capacity relative to BEV. Furthermore, the hypothesis is that stress CMR will be able to demonstrate differences in these hemodynamic parameters. CMR will also provide refined assessment of paravalvular leak and its impact on ventricular function and on clinical outcomes.
ENAVOgliflozin Outcome Trial in Patients With Severe Aortic Stenosis After Transcatheter Aortic...
Aortic Valve StenosisThe goal of this trial is to determine whether the use of a novel SGLT2 inhibitor(Sodium-glucose Cotransporter-2), Enavogliflozin is safe and effective for the improvement of adverse clinical outcomes and the reversal of adverse cardiac remodelling among patients who had undergone TAVR as compared with the standard-of-care therapy.
A Clinical Trial of the Transcatheter Aortic Valve Implantation System With a Prospective, Multi-Center,...
Aortic StenosisA Clinical Trial of the Transcatheter Aortic Valve Implantation System with a Prospective, Multi-Center, One-Arm Approach to Evaluate the Efficacy and Safety in the Treatment of Patients with Severe Aortic Stenosis
Cardiac Output, Cerebral Perfusion and Cognition in Patients Undergoing TAVI
Aortic Valve StenosisCognitive Impairment1 moreRationale: Cardiovascular disease and cognitive diseases are closely related. Cognitive impairment is common (21-39%) among patients with severe aortic valve stenosis. The proof-of-concept CP-TAVI study showed that increased cardiac output following transcatheter aortic valve implantation (TAVI) was associated with increased cerebral blood flow. It is hypothesized that increased cerebral blood flow (CBF) subsequently leads to improved cognitive functioning. Additionally, silent micro emboli caused by crushing of the calcified native valve during TAVI may cause cognitive deterioration. If it could be predicted which patients are at risk for TAVI induced cerebral micro emboli, these patients could benefit from cerebral protection devices, preventing cognitive decline. Objective: The objectives of the CAPITA study are 1A) to identify whether an increase in cardiac output after TAVI is associated with an increase of global CBF; 1B) explore regional differences in CBF after TAVI; 1C) determine whether (global or regional) increased CBF is associated with improved cognitive functioning; 1D) identify patient and procedural characteristics associated with increased cardiac output, CBF and cognitive functioning; 2A) identify the incidence and volume of new white matter hyperintensities after TAVI; 2B) evaluate patient and procedural predictors for the increase in white matter hyperintensities volume, including baseline aortic valve calcification volume, measured with computed tomography; 2C) if aortic valve calcification volume predicts new white matter hyperintensities, define a cut-off value for high-risk patients; 2D) assess whether the increase in white matter hyperintensity volume is associated with deterioration of cognitive scores. Study design: Prospective observational study, measuring cardiac output (echocardiography), cerebral blood flow (arterial spin labelling magnetic resonance imaging) and cognitive functioning (neuropsychological test battery) prior to TAVI (<24 hours to <one week) and at 3 months follow-up. At one year follow-up, cardiac output and cognitive function will be assessed. Study population: Patients with severe aortic valve stenosis eligible for transfemoral TAVI (n=142). Main study parameters/endpoints: Cardiac output (L/min), cerebral blood flow (mL/100g/min, change in %, relative to baseline) and cognitive functioning (extensive neuropsychological testing 60-90 minutes).
Progression of Ascending Aorta Diameters in Bicuspid Aortic Valve After Transcatheter or Surgical...
Bicuspid Aortic ValveAortic Valve Stenosis5 moreThe goal of this prospective, non-randomized, single-center, observational study is to assess whether there is a progressive dilation of ascending aorta after surgical or transcatheter aortic valve replacement (TAVR) in patients who underwent elective aortic valve replacement or TAVR for stenotic bicuspid aortic valve (BAV) at our institution from 2015 to June 2022. Participants will undergo both a CT and an echocardiographic assessment at least 90 days after surgery.
Impact of Beta Blockers on TAVI (BETA-TAVI)
Aortic Valve StenosisThis is a prospective, multicentre, investigator-initiated, randomized clinical trial clinical trial investigating the impact of beta-blockers administration among patients undergoing TAVI for severe aortic valve stenosis. Adults already receiving beta-blockers be assigned randomly in 1:1 ratio to either continue or withdraw the beta-blockers medication at least 72 hours before and at least 7 days after TAVI. The primary endpoint is permanent pacemaker implantation rates in 7 days after the procedure. Secondary endpoints include death, cardiogenic shock and arrhythmias/conduction abmormalities with time frame 12 months.
Evaluation of the Viability and Safety of Early Discharge Protocol After TAVI Implantation
Aortic Valve DiseaseAortic Valve Stenosis1 moreEvaluation of the safety and efficacy of early discharge (24 hours) after transfemoral transcatheter aortic prosthesis implantation (TAVI).
Hydra Registry - Italy Experience
Aortic Valve StenosisHydra-IT is a multicenter observational study aim to collect clinical, procedural and follow-up data and evaluate the short, medium and long term results of Hydra TAVI System in patient with severe aortic stenosis.
Transcatheter Aortic Valve Replacement (TAVR) Double Balloon Valvuloplasty
Aortic Valve StenosisIn this study, the investigators evaluate whether routine double inflation of the valve could have a lasting impact. The investigators hypothesize that a routine second reinflation of the balloon, or "double tap", will improve flow across the valve when compared to a single inflation. The investigators hypothesize that "double tap" (1) will decrease mean gradient between first and second inflation during the procedure, (2) will decrease mean gradient on immediate post procedure and 30 day postprocedure echocardiograms when compared to mean gradient gradient after single inflation. Less obstruction indicated by lower mean gradient early after deployment may translate to improved 5 and 10 year outcomes. Furthermore, the investigators hypothesize that this small change in technique will have no effect on procedure time or complications and the change will not result in any increase in perioperative vascular complications, or new permanent pacemaker insertion. The primary objective of this study is to determine if double valve inflation during a TAVR procedure improves valve area and mean gradients as measured by echocardiogram immediately following the procedure and at 30 days follow up.
Cardiac Imaging in Adults With Congenital Aortic Stenosis
Congenital Aortic StenosisThe CAS study is a prospective observational cohort study investigating the effects of congenital aortic stenosis (ConAoS) on the left ventricular function and the prevalence, pattern and expanse of left ventricular hypertrophy (LVH), myocardial stiffness and myocardial fibrosis.