Portico Valve-in-Valve Retrospective Registry
Aortic Valve StenosisAortic Valve Failure2 moreThe objective of this data-collection study is to retrospectively evaluate the safety and clinical performance of the Portico transthoracic aortic valve for Valve-in-Valve treatment of a failed aortic surgical bioprosthetic valve in patients who are considered at increased surgical risk for a redo surgical aortic valve replacement.
A 10-Minute Cardiovascular Magnetic Resonance Protocol for Cardiac Disease
Coronary Artery DiseaseMyocarditis8 moreThis study aims to identify and assess new CMR techniques that can improve current CMR protocols.
ALLIANCE AVIV: Safety and Effectiveness of the SAPIEN X4 Transcatheter Heart Valve in Failing Aortic...
Aortic Valve InsufficiencyAortic Valve StenosisThe objective of this study is to establish the safety and effectiveness of the Edwards SAPIEN X4 Transcatheter Heart Valve (THV) in subjects who are at high or greater risk with a failing aortic bioprosthetic valve.
Valve Hemodynamic Optimization Based on Doppler-Echocardiography vs Catheterization Measurements...
Aortic Valve StenosisAortic Valve Regurgitation1 moreData on valve performance following ViV-TAVR has usually been obtained with the use of Doppler-echocardiography. However, some reports have shown significant discordances in the evaluation of mean transvalvular gradient between echocardiography and catheterization, with an overestimation of the real gradient with echo (vs. cath) in most cases. Thus, the incidence of procedural-device failure may be lower than that reported in the ViV-TAVR literature,
Results of the Aortic Valve Reconstruction in Children
Aortic Valve InsufficiencyAortic valve disease counts up to 5% of cases of congenital heart disease being one of the most common congenital malformations of the cardiovascular system. This disease requires replacement of the damaged valve which in itself is not a trivial task to complete in children as there is still no available best practice for valve replacement. Today, the following alternative variants are performed in children: mechanical aortic prosthesis, xenografts, allografts, and pulmonary autograft (Ross procedure) and each has its potential advantages and disadvantages. Mechanical aortic prostheses require lifelong anticoagulation therapy and repeated surgeries to replace mechanical valves during child growth. Available xenografts in children also has suboptimal results not only because of absence of growth potential, but also due to development of degenerative changes in biological tissue of the graft leaflets. Allograft tissues are exposed to rapid biodegradation in the recipient body and thus requiring repeated surgeries associated with higher difficulty, high risk of hemorrhages, and injury of the coronary injuries. Ross procedure was proposed as theoretically the most evidence-based reconstruction of the aortic valve in children. Even successfully performed Ross operation transforms one-valve disorder into two-valve disease. The accumulation of knowledge on the anatomy of the aortic root and improvement of surgical techniques led to the development of new methods for reconstruction of the valve function. The technique is widely applied in adult cardiac surgery, uses glutaraldehyde-treated autopericardium for augmentation of the leaflets. Absence of foreign material provides no need for anticoagulation therapy. Potentially, reconstruction of the aortic valve with autopericardium can be widely used in children. Aim is to study safety, clinical and hemodynamic efficacy of the method of the aortic valve reconstruction with autopericardium in children with aortic valve disease. Patients aged 29 days to 12 years will be included into the study. The data according to the protocol of the study will be assessed at the stage of inclusion, during the surgery, in 30 days after the surgery, and in 1, 2, and 3 years after the surgery. Data about all the patients included into the research will be analyzed in order to study the endpoints and achieve the research aim.
Study on Efficacy, Safety and Durability of the UniLine Prosthesis in the Treatment of Aortic and...
Diseases of Mitral and Aortic ValvesRheumatic Disorders of Mitral and Aortic Valves3 moreAcquired heart diseases continue to remain one of the most common causes of cardiac mortality and morbidity. In the Russian Federation, open surgery treatment of acquired valvular heart diseases (AVHD) is performed in more than 40 regions by specialists from 92 healthcare organizations. Treating aortic or mitral valve disease using the "UniLine" biological prosthesis is expected to improve survival rates. Supposedly, in vivo the "UniLine" biological prosthesis will show optimal hemodynamic characteristics and high resistance to structural valve degeneration and infectious damage, thus lowering the risk of dysfunction. Moreover, the risk of repeated intervention due to dysfunction of the "UniLine" bioprosthesis should not exceed the risk of the primary implantation. Supposedly, in the case of dysfunction of "UniLine" bioprosthesis it would be possible to perform repeated replacement using valve-in-valve technique. The aim of the study is to assess the effectiveness, safety, durability of the "UniLine" epoxy-treated prosthesis and the long-term outcome of the treatment of isolated mitral and aortic valve diseases using this prosthesis. In accordance with the objectives and hypothesis, the following data will be analyzed: actuarial and linear survival rates (general and cardiac), non-lethal prosthesis-associated complications, prosthetic dysfunction and repeated interventions. Moreover, in vivo hemodynamic parameters of the prosthesis will be assessed: the area of the effective opening surface, peak and mean gradient of pressure and blood flow velocity. The study will be conducted at the Research Institute of Complex Issues of Cardiovascular Diseases. Study protocol received sponsorship approval and approval by Local Ethics Committee of the Research Institute and Research Coordinating Committee. The study will enroll patients who underwent isolated mitral or aortic valve replacement; transthoracic echocardiography will be conducted in all patients available for in-person visit.
To Evaluate Safety and Effectiveness of Transcatheter Aortic Valve System in Patients With Severe...
Aortic InsufficiencyTo Evaluate the Safety and Effectiveness of Transcatheter Aortic Valve System ( Chengdu Silara Medtech Inc. ,Chengdu, China)in Patients with Severe Symptomatic Aortic Insufficiency
Evaluation of Safety and Effectiveness of the EMBLOK EPS During TAVR
Aortic Valve StenosisAortic Valve Disease2 moreThe objective of the study is to evaluate the safety, effectiveness, and performance of the EMBLOK EPS during TAVR by randomized comparison with a commercially available embolic protection device. The targeted study population consists of patients meeting FDA-approved indications for TAVR with commercially available transcatheter heart valve systems. This prospective, multicenter, single-blind, randomized controlled trial will enroll up to a total of 532 subjects undergoing TAVR at up to 30 investigational sites in the United States. All subjects will undergo clinical follow-up (including detailed neurological assessments) in-hospital and at 30 days.
Outcomes of Type A Aortic Dissection Repair
Type A Aortic DissectionAscending Aortic Dissection5 moreType A aortic dissection (TAAD) is a potentially life-threatening pathology associated with significant risk of mortality and morbidity. In acute forms of type A aortic dissection (TAAD) mortality is 50% by 24 h and 50% of patients die before reaching a specialist center. Rapid diagnosis and subsequent prompt surgical repair remain the primary goal for these patients. In the last decade it has been observed that improvements in diagnostic techniques, initial management and increased clinical awareness have contributed to a substantial increase in the number of patients benefiting from a prompt diagnosis and undergoing surgery.However, survival after surgical repair has not yet reached optimal follow-ups and is burdened by high in-hospital mortality(16-18%)
CT-evaluation of Coronary Ostia Height After Surgical Aortic Valve Replacement.
Heart Valve DiseasesAortic Valve Stenosis11 moreThe goal of this interventional, single-center study is to demonstrate if there is a change in the coronary ostia height after surgical aortic valve replacement and if it depends on the type of prosthesis or surgical technique used. The study involves patients undergoing elective surgical aortic valve replacement with a bioprosthesis. Participants enrolled will undergo a CT scan before and after surgery (at least 90 days after surgery) to analyze coronary ostia height.