search

Active clinical trials for "Arrhythmias, Cardiac"

Results 81-90 of 689

Hexoskin Medical System - ECG Performance Testing

Cardiac Rhythm Disturbance

The goal of this observational study is to validate the efficacy of the Hexoskin Medical System (HMS) for its intended use (i.e., manual assessment of cardiac rhythm disturbances) in non-critical adult participants that are suspected of having an arrhythmia or have evidence of arrhythmia requiring monitoring via 24-hour Holter monitor. The main question it aims to answer are: Whether the HMS ECG recordings can be used to accurately detect cardiac beats when compared with the Holter monitor Whether there are high correlations between the HMS and Holter monitor in ECG characteristics Whether the HMS ECG recordings can be used to accurately classify cardiac rhythm/rhythm disturbance when compared with the Holter monitor What is the accuracy of using HMS ECG recordings to detect cardiac beats What is the accuracy of using HMS ECG recordings to identify cardiac rhythm/rhythm disturbance Participants will wear the HMS and the Holter monitor at the same time to record ECG signals. Researchers will evaluate the ECG recordings acquired from both devices and assess the above questions.

Recruiting9 enrollment criteria

Non-invasive Tool to Assess Electrophysiological Mechanisms in Cardiac Arrhythmias

Cardiac Arrhythmia

Noninvasive evaluation of the electrical status of the heart is based on the standard ECG but remains suboptimal due to difficulties with arrhythmia characterization and location. Electrocardiographic Imaging (ECGI) provides maps of cardiac electrical excitation in relation to the anatomy of the heart using an extensive number of electrodes from the body surface. The applicant will develop a systematic evaluation of the ECGI as a tool to detect cardiac regions of interest in cardiac arrhythmias.

Recruiting11 enrollment criteria

Ambulatory Leadless Electrocardiogram Recorder Trial Feasibility

ArrhythmiasCardiac3 more

The goal of this study is to compare the heart signals that are received by a new heart monitoring device called the HeartWatch to heart signals that are recorded by existing monitors used in cardiology clinics today. The main question[s] it aims to answer are: Does the HeartWatch recording allow characterization of tagged and abnormal arrhythmia events that are equivalent to the existing Event Recorder and Holter devices? Does the HeartWatch recording allow for detection of QRS complexes that are equivalent to the predicate Holter lead I reference signal? Participants who have been recommended to receive a heart monitor for heart rhythm assessment will asked to wear the HeartWatch armband monitor at the same time as the standard heart monitor. They will be asked to flag symptoms (if they occur) on either the HeartWatch or on the Helpwear Smartphone. When their monitoring session for the standard heart monitor is complete, then the monitoring session for the HeartWatch armband is also complete.

Recruiting13 enrollment criteria

Atropine vs Isoprenaline in the Invasive Diagnosis of Arrhythmias

Cardiac ArrhythmiaSupraventricular Arrhythmia

During electrophysiological study (EPS) multiple drugs are used to reveal arrhythmias and/or conductive system disorders. Two most often used agents are atropine and isoprenaline. Due to their distinct pharmacological properties, they are affecting myocardium in different manner. Those dissimilarities can affect the EPS course and long-term prognosis. The aim of presented study is to evaluate the optimal protocol of pharmacotherapy during EPS.

Not yet recruiting5 enrollment criteria

EP Device Registry

Cardiac Rhythm Disorder

This study will provide ongoing, high quality data on the safety, performance, and clinical benefits of Abbott's EP devices in a real-world setting.

Recruiting3 enrollment criteria

Prevention of Post-Operative Cardiac Arrhythmias

Cardiac; DysrhythmiaPostoperative1 more

Aim 1: Primary Prevention of Post-operative Cardiac Arrhythmias To evaluate the efficacy of dexmedetomidine vs. the combination of Magnesium Sulfate and dexmedetomidine for the prevention of post-operative cardiac arrhythmias in children and young adults undergoing open heart surgical repair for congenital or acquired heart disease using cardiopulmonary bypass. Dexmedetomidine is currently being administered to almost all patients after coming off cardiopulmonary bypass and in the CICU. For this aim, the investigator will be comparing dexmedetomidine administered alone or in combination with Magnesium Sulfate. To evaluate medication safety based on the frequency of Serious Adverse Events (SAEs) and Adverse Events (AEs) Aim 2: Secondary treatment of those Patients that develop a clinically significant arrhythmia despite having received either Dexmedetomidine alone or Magnesium Sulfate with Dexmedetomidine at the time of cardiac surgery To evaluate the efficacy of intravenous (IV) Amiodarone vs. IV Procainamide for the control of postoperative cardiac arrhythmias developing after the failure of Stage 1, Preventative Trial. IV amiodarone and IV procainamide are standardly used treatment agents for the treatment of postoperative cardiac arrhythmias in this setting. The investigator will be assessing the comparative effectiveness of these agents in controlling post-operative cardiac arrhythmias. To evaluate antiarrhythmic medication safety based on the frequency of SAEs and AEs

Not yet recruiting5 enrollment criteria

Clinical Validation of the AliveCor Kardia 12L and 6L Devices

Arrhythmia

AliveCor (www.alivecor.com) has developed an ECG device (KardiaMobile) that interfaces with iOS and Android smartphones and tablets. This ECG consists of a lightweight hardware case with two metal electrodes that can snap onto the back of the phone and a software application. By holding the right finger(s) on the right electrode and the left finger(s) on the left electrode, an electrical circuit is completed and a lead-I, 30 second rhythm strip is created. KardiaMobile and a newer device, KardiaMobile 6L, were approved by FDA for ECG rhythm recording. Recently, AliveCor developed two new devices: Kardia 12L and Kardia 6L to record 12- lead and 6-lead ECGs, respectively. However, the data generated from the two new devices have not yet been validated for accuracy. The purpose of this study is to evaluate the accuracy of the ECGs recorded by AliveCor Kardia 12L and 6L devices. This will be compared to simultaneous standard of-care 12-lead ECG recordings. The ECGs will be analyzed for accuracy and statistical difference using root-mean-square error and cross correlation between the median beats.

Active5 enrollment criteria

Full Early Atrial Diagnostics in Single Chamber ICD Patients Using the DX Lead and Home Monitoring...

ArrhythmiasCardiac

To demonstrate the value and benefits of BIOTRONIK's exclusive DX technology in assessing the incidence of supraventricular arrhythmias, mainly atrial fibrillation (AF), in patients with an indication for single chamber ICDs. Effects of the DX technology on related events, such as delivery of therapies and medical management, including eventual complications. Extended benefits offered by DX devices when associated with daily remote monitoring, by means of BIOTRONIK's Home Monitoring Service Center (HMSC).

Recruiting12 enrollment criteria

DiamondTemp Global Registry

Arrhythmia

The DiamondTemp™ Global Registry is a prospective, global, multi-center, observational post-market registry.

Recruiting5 enrollment criteria

Product Surveillance Registry

Cardiac Rhythm DisordersUrological Disorders17 more

The purpose of the Registry is to provide continuing evaluation and periodic reporting of safety and effectiveness of Medtronic market-released products. The Registry data is intended to benefit and support interests of patients, hospitals, clinicians, regulatory bodies, payers, and industry by streamlining the clinical surveillance process and facilitating leading edge performance assessment via the least burdensome approach.

Recruiting6 enrollment criteria
1...8910...69

Need Help? Contact our team!


We'll reach out to this number within 24 hrs