search

Active clinical trials for "Atrial Fibrillation"

Results 1-10 of 3148

Effect of Prolonged Use of Dronedarone on Recurrence in Patients With Non-paroxysmal Atrial Fibrillation...

Atrial Fibrillation

Recurrence rate remains high after radiofrequency ablation in patients with non-paroxysmal atrial fibrillation(AF). Prolonged use of anti-arrhythmic drugs (AAD) beyond the post-ablation blanking has been adopted as a solution but without sufficient clinical evidence. Dronedarone is an AAD valid to maintain sinus rhythm and has fewer side effect than other AAD for long-term use.We sought to investigate the effect of prolonged use of dronedarone on recurrence of non-paroxysmal AF patients beyond the post-blanking period within the first year after ablation.

Recruiting23 enrollment criteria

Left Atrium Reservoir Function Modulation in Patients With Atrial Fibrillation: Digoxin Versus Beta...

Atrial FibrillationLeft Atrial Rhythm

ß blocker and digoxin effect on left atrium reservoir function are unknown. This is a randomized open label study to compare the effect of theses two molecules on left atrium function

Recruiting12 enrollment criteria

Comparison of Cryoballoon vs. Pulsed Field Ablation in Patients With Symptomatic Paroxysmal Atrial...

Paroxysmal Atrial Fibrillation

Pulmonary vein isolation (PVI) is an effective treatment for atrial fibrillation (AF). Currently, Medtronic Arctic Front Cryoballoon is the most frequently used single shot technology and hence is the benchmark for upcoming technologies. A novel method, pulse-field ablation (PFA) using the FARAPULSE catheter, has recently been introduced (FARAPULSE PFA, Boston Scientific). However, whether FARAPULSE PFA provides effectiveness similar to the standard-of-practice Medtronic Arctic Front Cryoballoon is yet to be investigated. Given that FARAPULSE PFA has shown in studies not to cause any of the severe complications reported in association with traditional PVI while being highly effective, it might be even safer and more effective for use in AF ablation procedures. The aim of this trial is to compare the efficacy and safety of PVI using FARAPULSE PFA (Boston Scientific) and the Arctic Front Cryoballoon (Medtronic) in patients with symptomatic paroxysmal AF undergoing their first PVI. This is an investigator-initiated, multicenter, randomized controlled, open-label trial with blinded endpoint adjudication. Given that the Medtronic Arctic Front Cryoballoon is the standard-of-practice for PVI and the FARAPULSE PFA is the novel technology, this trial has a non-inferiority design. The null hypothesis with regards to the primary efficacy endpoint is that the FARAPULSE PFA (Boston Scientific) shows lower efficacy compared to the Arctic Front Cryoballoon (Medtronic) and that therefore more episodes of first recurrence of any atrial arrhythmia between days 91 and 365 will be observed in patients with symptomatic paroxysmal AF undergoing their first PVI. Hence, the alternative hypothesis postulates that the FARAPULSE PFA is non-inferior to the Arctic Front Cryoballoon. Rejection of the null hypothesis is needed to conclude non-inferiority.

Recruiting30 enrollment criteria

Flecainide Versus Amiodarone in the Cardioversion of Paroxysmal Atrial Fibrillation at the Emergency...

Atrial Fibrillation ParoxysmalCoronary Artery Disease Without Residual Ischemia

Current guidelines for the cardioversion of paroxysmal Atrial Fibrillation at the Emergency Department do not prioritize between antiarrhythmic agents and do not consider the time taken for successful cardioversion. Furthermore, the use of flecainide -a class 1C antiarrhythmic agent- is contraindicated for the cardioversion of patients with revascularized coronary artery disease, as well as patients with ischemic cardiomyopathy and preserved ejection fraction. These recommendations stem from insufficient data, mainly from the CAST study. The present study is a prospective, multicentre, randomized clinical trial. The primary goals of this clinical trial are to prove the superiority of flecainide over amiodarone in the successful cardioversion of paroxysmal atrial fibrillation at the Emergency Department, and to prove that the safety of flecainide is non-inferior to amiodarone, in patients with coronary artery disease without residual ischemia and ejection fraction over 35%. The secondary goals of the study are to prove the superiority of flecainide over amiodarone in the reduction of hospitalizations from the Emergency Department due to atrial fibrillation, in the time taken to achieve cardioversion, and to the reduction of the need to conduct electrical cardioversion. The study population will be all consecutive new-comers to the Emergency Department with primary diagnosis of paroxysmal atrial fibrillation and history of coronary artery disease without angina, without residual ischemia and with ejection fraction > 35%. The sample size will be 200 patients, who will be monitored for 30 days. At the Emergency Department, all patients will be under continuous ECG monitoring, and a 24-hour ECG device will also be placed (Holter). The patients will be randomized to the treatment group (flecainide) and the control group (amiodarone). Patients in both arms will stay at the ED for a total of 6 hours after therapy initiation. If no adverse events occur in this time, the patient will be discharged from the ED. Otherwise, the patient will be admitted to the hospital. At 24 hours, the patients will visit the study centre for physical examination, ECG, cardiac ultrasound, 24-hour ECG removal and adverse events evaluation. At 30 days, follow-up via phone calls will be conducted for the evaluation of the study outcomes and adverse events.

Recruiting40 enrollment criteria

A Study of Multi-electrode Circular Irreversible Electroporation (IRE) Catheter and Multi-Channel...

Refractory Paroxysmal Atrial Fibrillation

The purpose of this study is to evaluate the long term off-Antiarrhythmic Drug (AAD) effectiveness of Biosense Webster, Inc. Irreversible Electroporation (BWI IRE) system in treatment of participants with symptomatic drug refractory paroxysmal atrial fibrillation (PAF).

Recruiting9 enrollment criteria

The PIFPAF-PFA Study

Persistent Atrial Fibrillation

Pulmonary vein isolation (PVI) is very effective for rhythm control in patients with paroxysmal atrial fibrillation (AF), but less successful in patients with persistent AF. Adding posterior wall ablation (PWA) to PVI is among the most promising ablation strategies to improve arrhythmiafree outcome in patients with persistent AF. Patients with left atrial posterior wall scar may benefit most from adding PWA to PVI. With previous ablation technology, posterior wall isolation (PWI) was difficult to achieve and increased the risk of procedural complications. With pulsed-field ablation (PFA), a technology is now available which is both very effective and safe for complete ablation of the posterior wall. The aim of this trial therefore is to compare the efficacy and procedural safety of two ablation strategies for the treatment of persistent AF using PFA: PVI only versus PVI with added PWA. The endpoint of atrial arrhythmia recurrence within 12 months will be assessed by an implantable cardiac monitor (ICM) with remote monitoring capabilities.

Recruiting34 enrollment criteria

A Study For Treatment of Paroxysmal Atrial Fibrillation (PAF) With the OMNYPULSE Catheter and the...

Atrial Fibrillation

The purpose of this study is to demonstrate safety and effectiveness of the ablation system (OMNYPULSE Bi-directional catheter and TRUPULSE generator) when used for isolation of the atrial pulmonary veins (PVs) in treatment of participants with paroxysmal atrial fibrillation (PAF).

Recruiting37 enrollment criteria

Efficacy Comparison of High and Very High Power Short Duration Pulmonary Vein Isolation

Atrial Fibrillation

Objective: To evaluate the long-term durability of PVI performed with 90W and 50W (QDot catheter). Primary hypothesis: Pulmonary vein isolation is equally highly effective when performed with 50W guided by ablation index (QMODE) and inter-tag distance <5 mm and when performed with 90W (QMODE+) and inter-tag distance <5 mm. Study Design: 40 patients will be randomized in a 1:1 ratio to 50W and 90W PVI. Study procedures: Initial PVI will be performed via femoral access and double transseptal puncture guided by fluoroscopy and pressure monitoring. If necessary intracardiac echocardiography (ICE) will be used for the transseptal puncture. A fast anatomical left atrial map will be created with a multipolar mapping catheter; then, point-by-point PVI will be performed with QDot catheter with 50W or 90W according to randomization. Three months after the initial procedure, patients will undergo a repeated high density left atrial mapping with PentaRay or OctaRay catheter to evaluate the durability of the PVI. Exact gap numbers and locations will be registered. If necessary, reablation of the pulmonary veins (rePVI) will be performed. Inclusion criteria: Symptomatic paroxysmal/persistent AF, >18 years, willingness to sign informed consent form. Exclusion criteria: Long-standing persistent AF, active malignancy, contraindication for anticoagulant therapy, life expectancy <1 year, valvular AF, hyperthyroidism. Endpoints: At repeat procedure, a high density left atrial map will be created with PentaRay or if available OctaRay catheter to evaluate the durability of the PVI. Primary endpoint will be pulmonary vein reconnection.

Recruiting13 enrollment criteria

Atrial Fibrillation Follow-up Investigation to Recover Memory and learnING Trial

Cognitive ImpairmentAtrial Fibrillation

The objective of the study is to evaluate the effectiveness of cognitive training in people with atrial fibrillation and cognitive decline over 12-week cognitive training. Moreover, the investigators will explore whether the training effect can be maintained.

Recruiting18 enrollment criteria

Rural Hospital-Level Care at Home for Acutely Ill Adults

InfectionsHeart Failure9 more

This study examines the implications of providing hospital-level care in rural homes.

Recruiting73 enrollment criteria
12...315

Need Help? Contact our team!


We'll reach out to this number within 24 hrs