Pacemaker Implantation Versus Cardioneuroablation for Functional Atrioventricular Block
Atrioventricular BlockThe TELE-SPACER study is a multicenter, noncommercial, physician-initiated, proof-of-concept, prospective, randomized, controlled, unblinded clinical trial and registry designed to compare two methods of treatment of patients with functional Atrio-Ventricular Block (AVB): the guidelines-recommended elective pacemaker (PM) therapy vs cardiovascular autonomic tests (CAT), electrophysiologic assessment (EPS) with referral to cardioneuroablation (CNA) and reevaluation of indications for PM therapy. The main questions TELE-SPACER aims to answer are: Can the investigators successfully treat functional AVB without implantable device (PM)? Can the investigators prove the feasibility and safety and demonstrate non-inferiority of CNA procedure in patients with functional AVB, avoiding long-term permanent pacing, its limitations, complications and costs ? The TELE-SPACER trial will validate the European Society of Cardiology (ESC) recommendations (level C of evidence: expert opinion) for elective PM implantation and will introduce CNA as effective treatment in the functional AVB patient population. Functional AVB - defined as a persistent or paroxysmal AVB with a positive results of atropine test
The Impact of LBBAP vs RVP on the Incidence of New-onset Atrial Fibrillation in Patients With Atrioventricular...
Left Bundle Branch Area PacingRight Ventricular Pacing2 moreThis is a single-center, randomized controlled study. The aim of this study is to compare the impact of left bundle branch area pacing versus traditional right ventricular pacing on the incidence of atrial fibrillation in patients with atrioventricular block.
PReventive Effect Of Left Bundle Branch Area Pacing Versus righT vEntricular paCing on All Cause...
BradyarrhythmiaAtrioventricular Block1 morePROTECT-SYNC study is a multicenter, randomized, controlled trial. A total of 7 medical centers across Republic of Korea will enroll 450 patients during 2 years of enrollment period, and followed for 2 years of follow-up period. The purpose of this study to compare the clinical outcomes of Left Bundle Branch Area Pacing (LBBAP) compared to Right Ventricular Pacing (RVP) in bradyarrhythmia patients who require high burden of ventricular pacing (>40%).
Physiologic Cardiac Pacing to Prevent Left Ventricular Dysfunction Post TAVI
Atrioventricular BlockSecond and Third DegreeThe study aims to compare permanent Conduction System Pacing (CSP) with the standard therapy - Right Ventricular Pacing (RVP) or Biventricular Pacing (BVP) - in preventing the development and progression of symptomatic Chronic Heart Failure (CHF) and improving survival in patients after Transcatheter Aortic Valve Implantation (TAVI).
Taiwan Registry for Leadless Pacemaker
Sick Sinus SyndromeAtrioventricular BlockTaiwan Registry for Leadless Pacemaker is a nationwide registry for leadless pacemaker performance in Taiwan.
Temporary Transvenous Pacemaker Placement by Intracavitary Electrocardiogram Monitoring
Bradycardia; SyncopeBradyarrhythmia4 moreTraditional temporary pacing catheter insertion by intracavitary electrocardiogram (IC-ECG) monitoring which only monitoring tip polar, the negative one. The investigators modified the technique by monitoring both negative and positive polar which will be precisely locating catheter tip and indicating the direction of the catheter tip. Extensively used temporary pacing catheter tip has two electrodes which are about 1 cm apart. Distal electrode is negative (-) and active, proximal electrode is positive (+) and indifferent. Investigators use both distal (-) and proximal (+) electrodes which can be attached to any two of the V leads, record as V(-) and V(+). Monitoring positions of the electrodes by V(-) and V(+) could provide more information about the tip position. Comparing the QRS amplitudes between V(-) and V(+), when catheter tip enters right ventricle chamber: the case of V(-) > V(+) infers tip toward apex ventricle wall ; conversely, the case of V(-)<V(+) indicates tip directs to outflow tract. The investigators hypothesis this monitoring will help precisely placement.
Left Bundle Area Versus Selective His Bundle Pacing
BradycardiaSinus Node Dysfunction1 moreThis is a voluntary research study to find out which location in the heart a pacemaker wire is the most efficient for a patient's heart and for battery life. Patients who volunteer and are eligible for the study will be randomized to receive one of two positions for the wire to be screwed into, in addition to studying multiple positions in the heart during the pacemaker insertion. Enrolled patients will be in the study for 1 year. They will also have an Ultrasound of their heart performed to assess how the pacemaker wire is affecting their heart. Pacemakers are connected to the heart by wires that are screwed into the heart. The wires can be connected to the heart in different places, which can affect how well the heart beats over time. The typical position is at the tip of the heart. This position may cause the heart to beat inefficiently. Over time, this could lead to weakened heart muscle, irregular heart rhythm, and more hospitalizations. The heart has special muscle cells and fibers that carry electrical signals through and around the heart. An alternative spot to place the pacemaker wire is in an area where these special cells are grouped together (called the HIS bundle). The pacemaker wire can be connected to the heart at a location which may allow the heart to beat more efficiently when compared to putting the wire at traditional spots in the heart (called HIS bundle pacing). However, sometimes connecting the wire into the HIS bundle may cause the pacemaker battery to wear out faster. Physicians can also connect the pacemaker wired near the HIS bundle (called Left left Bundle bundle area pacing). The study physicians hope this will allow the heart to beat more efficiently without causing the battery to wear out faster. The study physicians would like to study how different wire positions change heart beat efficiency and how long the pacemaker battery lasts when the wires are placed in different locations. This study will connect the pacemaker wire at either the HIS Bundle or the left bundle area pacing, to see how effectively the heart pumps and how much battery is being used.
Safety and Performance Study of the Moderato System
Hypertension Resistant to Conventional TherapyBradycardia1 moreThe purpose of the study is to evaluate the safety and performance of the Moderato System by implanting the Moderato pacemaker in patients who require a dual chamber pacemaker, and who also have hypertension, in order to reduce their blood pressure.
Impact of Atrio-ventricular Optimization With His Bundle Pacing on Treatment of Atrio-ventricular...
Atrioventricular BlockAtrioventricular DyssynchronyThis study aims to determine the clinical and hemodynamic benefit of atrio-ventricular (AV) resynchronization with His bundle pacing in patients with symptomatic first degree AV block.
Spontaneous Atrio Ventricular Conduction Preservation
Sinus Node DysfunctionBradycardia-Tachycardia Syndrome1 moreIn case of sinus node dysfunction, it is often necessary to choose the safer option provided by a DDD pacemaker even though the most appropriate mode of pacing is AAI mode. In addition to saving energy, the latter mode allows spontaneous ventricular activation, the haemodynamic consequences of which are, in most cases, better than those obtained with dual chamber pacing. Recent studies as the MOST study suggest also that ventricular desynchronization imposed by right ventricular apical pacing even when AV synchrony is preserved increases the risk of atrial fibrillation in patients with SND. Similar results were already given by anterior studies (PIPAF) which, taking into account the percentage of ventricular pacing, suggested that AF prevention algorithm in combination with a preserved native conduction are efficient in reducing AF burden. However, current practice is to implant a dual chamber pacemaker to prevent the risk of atrioventricular block (AVB) even if DDDR pacing with a fixed long AV delay was found inefficient in reducing ventricular pacing and was associated with a high risk of arrhythmias. The Symphony 2550 cardiac pacemaker offers pacing modes that automatically switch from AAI(R) mode to DDD(R) or DDI(R) in event of severe atrioventricular conduction disorder, irrespective of whether or not these are accompanied by an atrial arrhythmia, returning spontaneously to AAI(R) mode as soon as the spontaneous AV conduction has resumed. These 2 particular modes are called the AAI SafeR and DDD/AMC (R) mode. The main differences between both modes are that (i) AAI SafeR does not trigger any AV Delay after a sensed or paced atrial event which allows long PR intervals or even limited ventricular pauses with no switch to DDD(R), while (ii) DDD/AMC (R) is able to optimize AV Delay after switching to DDD(R) according to measured spontaneous conduction times and to provide an acceleration in case of vaso-vagal syndrome. This pacing mode has previously been assessed in clinical studies. This study intends to demonstrate that the automatic modes switching significantly reduce the percentage of ventricular pacing in patients implanted with a spontaneous AV conduction and reduce the occurrence of atrial arrhythmias, on a mid-term follow-up period, in comparison to standard DDD pacing with long AVDelay.