search

Active clinical trials for "Diabetes Mellitus, Type 1"

Results 2301-2310 of 2981

The Diabetes Prevention Trial of Type 1 Diabetes (DPT-1)

Diabetes MellitusType 1

The Diabetes Prevention Trial of Type 1 (DPT-1) was a multicenter randomized, controlled clinical trial designed to determine whether it is possible to delay or prevent the clinical onset of type 1 diabetes through daily doses of insulin in individuals determined to be at risk for the disease. Subjects were recruited from study clinics and through media campaigns.First-degree relatives, 3 to 45 years of age, and second-degree relatives, 3 to 20 years of age, of patients with diabetes were screened for islet-cell antibodies. Those individuals found to be at high risk of diabetes were randomized to receive either close observation or low-dose parenteral insulin. Those individuals found to be at intermediate risk of diabetes are randomized to receive insulin orally or to receive placebo. Patients were followed for up to six years.

Completed8 enrollment criteria

FreeStyle Libre Plus Bluetooth Transmitter Adjunct: Can This Improve Glucose Accuracy and Reduce...

Type1 Diabetes Mellitus

Advanced glucose monitoring systems have revolutionized diabetes care and enabled people with diabetes to achieve better diabetes control with reduced risk of hypoglycaemia. Continuous glucose monitoring (CGM) systems provide real-time glucose monitoring and alarms when glucose approaches extreme readings (hypoglycaemia and hyperglycaemia) or when the change in glucose is rapid. All available CGM systems, except Dexcom G6, require daily calibrations with capillary glucose readings in order to attain accuracy of glucose readings. Decom G6 system is not widely accessible and only available in certain countries. Flash glucose monitoring systems (Flash) provide glucose readings when users actively scan their sensors. FreeStyle Libre (FSL) is the only Flash glucose monitoring system currently available in market. FSL is factory calibrated and sensors are ready to use after placement and initiation. The two main differences between Flash and CGM are user interaction and the alarm facility. While CGM provide real-time glucose readings, Flash is user-dependent for actively scanning and understanding the readings. Moreover, CGM systems provide alarms for low or high glucose and for rapid glucose changes, while Flash does not routinely provide alarms. This is particularly relevant when patients have impaired or lost hypoglycaemia awareness. CGM systems are costlier compared to Flash, which has contributed to the wider adoption of FSL. Several Bluetooth adjuncts have been introduced to market for FSL. These devices attach to Libre sensor and connect to the user's mobile phone via Bluetooth. This enables continuous and real-time feed of glucose readings from the sensor to patient's mobile phone, which enables a wide range of customizable alarms for high and low glucose levels and for rapid glucose changes. This setup also enables calibration of Libre sensor with capillary glucose which, anecdotally, has been reported to improve sensor accuracy. None of these adjuncts have been validated clinically. FSL with Bluetooth adjunct such as MiaoMiao remain cheaper than current CGM options and could be more accessible in some countries than CGM. However, without robust evidence to support effectiveness and safety of such setup it is not possible to recommend this. The Objective of this study is to determine whether FSL with Bluetooth Adjunct is superior to FSL alone in accuracy and reduction of hypoglycaemia burden.

Withdrawn15 enrollment criteria

A Study of a New Type of Insulin in Participants With Type 1 Diabetes on Insulin Injection Therapy...

Diabetes MellitusType 1

The study will be conducted in participants with type1 diabetes on insulin injection therapy to investigate how the body processes a test formulation of insulin lispro and the effect of the test formulation on blood sugar levels. Side effects and tolerability will be documented. The study will be conducted in two parts (Part A and Part B) to achieve its objectives. Participants are expected to enroll in both parts.

Withdrawn11 enrollment criteria

A Study to Evaluate Safety, Pharmacokinetics, and Pharmacodynamics of a Single Dose of SAR438544...

Type 1 Diabetes Mellitus

Primary Objective: To assess the pharmacodynamic response (PD) of a single subcutaneous (SC) dose of SAR438544 versus recombinant glucagon in type 1 diabetes mellitus (T1DM) patients under induced hypoglycemia. Secondary Objective: To assess the safety and tolerability and pharmacokinetics (PK) of a single SC dose of SAR438544 versus recombinant glucagon in T1DM patients under induced hypoglycemia.

Withdrawn31 enrollment criteria

The Impact of Mobile Technology on Clinical Outcomes in Children and Adolescents With Type 1 Diabetes...

Diabetes MellitusType 1

The purpose of this study is to determine whether a simple text message reminder sent to the parent of an child/adolescent with Type 1 Diabetes(or parent and adolescent) is effective in helping the individual(or parent) become more compliant with self-managing the Type 1 Diabetes (T1D). There will be 5 arms: text message sent to parents of children age 8-12 years old with T1D, text messages sent to parents of adolescents ,age 13-18 years old, with T1D,text messages sent to parents of adolescents with T1D as well as the adolescent with T1D,no text message sent to parents of children age 8-12 years, and no text message sent to adolescents or parents of adolescents age 13-18 years old.

Withdrawn11 enrollment criteria

The Diabetes Patient-Reported Outcome Measures Trial

Diabetes MellitusType 1

The study aim to evaluate the use of Patient-Reported Outcome Measures in clinical diabetes consultations.

Withdrawn7 enrollment criteria

Intranasal Insulin and Its Effect on Postprandial Metabolism in Comparison to Subcutaneous Insulin...

Type 1 Diabetes Mellitus

The purpose of this study is to determine if glucose peaks higher and earlier after a meal when a patient is given intranasal insulin instead of conventional insulin treatment.

Withdrawn10 enrollment criteria

Micro Glucagon During Exercise in Type 1 Diabetes

Type 1 DiabetesHypoglycemia

This proof-of-principle study to assess effects of different doses (mini and micro) of subcutaneous glucagon analog Dasiglucagon (Zealand Pharma, Copenhagen, Denmark) on the change in blood glucose concentration during moderate-intensity exercise in people with T1D.

Withdrawn11 enrollment criteria

Evaluation of 18F-FP-DTBZ Pancreatic PET Scanning as a Tool to Measure Beta Cell Mass

Healthy VolunteersDiabetes Mellitus1 more

Type 1 diabetes mellitus (T1DM) develops when there is impaired insulin production due to loss of insulin producing cells (beta cells). The amount of insulin that can be produced is imperfectly correlated with beta cell mass (BCM). The development of a reliable method to noninvasively quantify the total amount of insulin producing beta cells would be of great benefit by providing an important endpoint for the development of new treatments of diabetes. The investigators have previously identified a specific marker on islet cells called vesicular monoamine transporter 2 (VMAT2) that the investigators now propose to use in positron emission tomography (PET) scanning to determine islet beta cell mass. The PET radiopharmaceutical 18F-fluoropropyl(FP)-dihydrotetrabenazine(DTBZ) has been used previously in human subjects without adverse effects. It has shown promise in differentiating type 1 diabetes and non-diabetes. The investigators now hypothesize that repeat PET scans will be reproducible in the same subject. Subjects with normal BCM will be recruited from among normal weight non-diabetic people with plasma insulin levels within the normal range. Subjects with predicted reduced BCM will be recruited from among patients with T1DM who have low or non-measurable insulin levels. Two PET scan measurements will be taken in each subject and the amount of VMAT2 in the pancreas will be and compared for reproducible findings. Biochemical testing will also be performed and compared to PET scans as a potential indirect marker of beta cell mass.

Withdrawn39 enrollment criteria

Role of Pregnancy Related Hormones in Lowering the Insulin Requirement in Pregnant Women With Type...

Type 1 Diabetes

This is a randomized, double-masked, placebo-controlled, single-center study to evaluate stimulated C-peptide secretion after exogenous administration of mild immunosuppression and growth-promoting factors to women with preexisting T1DM who had a decline in insulin requirement or had detectable C-peptide during a previous pregnancy. Fifteen subjects will be enrolled and randomly assigned in a 2:1 ratio to either active treatment or placebo in a parallel group design. Participation for individual subjects will consist of an initial Screening Visit, a 2-week baseline period, a Baseline Visit, visits at week 2 and 4 of the treatment period, a visit at the end of the treatment period (week 6), and a follow-up visit 2 weeks after study treatment discontinuation. Subjects will receive either active treatment or matching placebo of estradiol 1 mg every 8 hours; medroxyprogesterone 2.5 mg every 24 hours; hydrocortisone 2.5 mg every morning, 1.25 mg every afternoon, and 1.25 mg at bedtime each night; and growth hormone 2 mg once a day).

Withdrawn21 enrollment criteria
1...230231232...299

Need Help? Contact our team!


We'll reach out to this number within 24 hrs