Effect of Sedative Agent on Reducing the Frequency of Arrhythmia in the Patients After Cardiac Surgery...
ArrythmiaArrhythmias early in the recovery period after cardio thoracic surgery are common they develop in 11 to 40 percent of patients after coronary-artery bypass grafting. The right chose of sedative agent could decrease the level of arrhythmia incidence.
Maestro Handheld Cardiac Monitor Validation
Cardiac ArrhythmiaThe purpose of this study is to demonstrate that the Maestro hand held heart monitor can accurately diagnose Atrial Fibrillation, atrial flutter or normal sinus rhythm in patients.
Impact of an Intensive Monitoring Strategy in Symptomatic Patients With Suspected Arrhythmia
Suspected ArrhythmiaHypothesis: Patients that were previously discharged from the emergency department with a subsequent non-diagnostic 30 day external patch monitor for suspected arrhythmia will benefit from early Reveal LINQ™ Insertable Cardiac Monitoring System placement. Primary Study Objectives: To evaluate the outcome of an intensive monitoring strategy (patients with a negative 30 day SEEQ™ Mobile Cardiac Telemetry (MCT) System result are purposed over for a Reveal LINQ™ Insertable Cardiac Monitoring System) in patients with suspected but no previously documented arrhythmias that result in a clinically actionable event.
Validation of an iPhone-based Event Recorder for Arrhythmia Detection
ArrhythmiaPalpitations1 moreIn this study, we will evaluate the diagnostic yield of the new AliveCor device versus a 14 day event monitor with the use of both devices simultaneously. We will also examine by means of a questionnaire the compliance, ease of use and patient satisfaction for each device. Hypothesis: The AliveCor monitor will be non-inferior to the 14 day event monitor with respect to diagnosis of the arrhythmia responsible for a patient's symptoms. The AliveCor monitor will have better compliance and acceptability compared to the 14 day event monitor, and thus there will be a greater number of days with recordings from the AliveCor monitor.
Non-invasive Mapping of Rhythm Disorders
Cardiac Rhythm DisordersThis current care protocol follows the biomedical research protocol entitled "Non-invasive mapping of the heart ECG high amplification" that demonstrated the clinical value of noninvasive Cardioinsight® mapping system. Guide the management of patients hospitalized for cardiac rhythm radiofrequency ablation of cardiac arrhythmias, implantation or programming of a pacemaker, or assess the risk of serious arrhythmias or sudden death, with the currently used non-invasive mapping routine. The results obtained with non-invasive mapping will be compared with those obtained with the conventional method without non-invasive mapping.
Electroanatomical Mapping of Patients Undergoing Catheter Ablation Procedures Using Rhythmia Mapping...
Cardiac ArrhythmiasThe purpose of this study is a feasibility study for the Rhythmia Medical Mapping System and Mapping Catheter on patients undergoing catheter ablation procedures for the treatment of cardiac tachyarrhythmias.
Changes in Blood Gases, Disturbance of Breath During Sleep and Cardiovascular Co-morbidity in COPD...
Pulmonary DiseaseChronic Obstructive4 moreRespiration failure type 2 is loss of the lungs ability to take up oxygen (O2) and get rid of carbon dioxide (CO2). The diagnosis is based on blood gas measurement of pressures of O2 and CO2. Patients with COPD is often seen to have co-morbidity with cardiac diseases. Chronic systemic inflammation is seen in both COPD and cardiac diseases. The investigators will investigate the sleep quality, CO2-retention, O2-saturation, cardiac arrythmias and markers of inflammation in 120 patients with COPD in different stages of the disease. Our hypotheses are: that the first signs of respiration failure type 2 is seen during sleep with alteration of sleep patterns and greater and more long-lasting retention of CO2 in the blood compared to those with a normal lung function that the use of alcohol, zopiclone or supplementary oxygen will make these differences even greater that cardiac arrythmias correlates with hypoxemia that cardiac arrythmias and respiration failure correlates with degree of inflammation
Skin Sympathetic Nerve Activity and Cardiac Arrhythmias
Sympathetic Nerve ActivitySince the invention of electrocardiogram (ECG), ECG has been an important part of clinical practice. A primary reason for the popularity of the ECG is that it is non-invasive and can be performed in any patient by placing electrodes on the skin. The present methods of ECG recording focus on detecting electrical signals from the heart. the investigators propose that with high frequency sampling and high pass filtering, the investigators can also record SNA from the skin. The somata of the subcutaneous sympathetic nerves on the skin are located at the ipsilateral cervical and stellate ganglia. Because the left stellate ganglion nerve activity (SGNA) is known to trigger cardiac arrhythmias, including AF, VF and VF, It is possible that skin SNA can also be used for arrhythmia prediction. the investigators tested that hypothesis in our preclinical studies (supported by R01 HL71140) using canine models. The results showed that subcutaneous nerve activity (SCNA) recorded with implanted electrodes can be used to estimate stellate ganglion nerve activity(SGNA) in normal dogs and in a canine model of ventricular arrhythmia and sudden death. the investigators also showed that SCNA is more accurate than heart rate variability in estimating cardiac sympathetic tone in ambulatory dogs with myocardial infarction.Therefore, SKNA and SCNA may be useful in estimating cardiac sympathetic tone. In addition to studying the autonomic mechanisms of cardiac arrhythmia, these new methods may have broad application in studying both cardiac and non-cardiac diseases. For example, sympathetic tone is important in the pathogenesis of heart failure, atherosclerosis, peripheral neuropathies, epilepsy, vasovagal syncope, renal failure, hypertension and many others diseases. Direct SKNA and SCNA recording may provide new approaches to study the mechanisms of these common diseases. SKNA recording may also have immediate clinical applications by assisting in the diagnosis and treatment of hyperhidrosis (sweaty palms), paralysis, stroke, diabetes, and neuromuscular diseases. It may be used to assist biofeedback monitoring performed by neurologists to control neuropsychiatric disorders. Because of these potential clinical and commercial applications, the investigators propose that this research project is significant. b. Innovation Using conventional electrodes on the skin to record SNA. The neuECG utilizes the conventional skin electrodes that are widely used in health care facilities. Skin SNA had been recorded using microneurography techniques, and had been estimated using cutaneous blood flow (vasodilator responses) skin temperature, skin conductance and sweat release. However, microneurography cannot be used in ambulatory patients. The other methods are not direct measurements of SNA. neuECG is the first method that can directly and non-invasively measure the SNA from the skin. Automated real-time signal processing. the investigators will develop signal processing software to automatically eliminate noise, such as that generated by muscle contraction, electrical appliances, body motion, respiration, and radiofrequency signals. The remaining signals are then processed to separately display in real time to provide health care providers a new method to instantly estimate sympathetic tone. The ECG signals are used for automated arrhythmia detection while the SNA signals are available for risk stratification. This approach allows us to improve and broaden the clinical application of Einthoven's original invention by simultaneous detecting ECG and SNA from the skin. SKNA patterns as new biomarkers. the investigators have identified unique SKNA patterns that precede the onset of human AF. If proven correct by Specific Aim 3, this new biomarker can help physicians to estimate the arrhythmia risk and to predict the efficacy of catheter ablation for AF.
CLAIM: Using the KODEX-EPD System to Guide PaCing Lead Placements, A First In Man Study.
Cardiac ArrhythmiaProspective, multi-center (2-3 sites), non-randomized, open label, single arm 3 phase study: Phase 1 or Evaluation Phase: Where the KODEX-EPD System will be used to exclusively monitor the entire implantation procedure; the KODEX-EPD system will not be used for guidance during the lead implantation workflow. Phase 2 - KODEX-EPD-assisted Phase: Where the KODEX-EPD system will be used for cardiac imaging acquisition, guidance during lead implantation in conjunction with fluoroscopic imaging Phase 3 - KODEX-EPD-guided Phase: Where the KODEX_EPD System will be used as the leading imaging modality during the lead implantation workflow. Fluoro can be used; up until the part of the lead implantation workflow that is the scope of this investigation. As a bailout, when the operator declares failure to attempt.
Safety of Phenylephrine Hydrochloride, Acetaminophen, Dimethindene Maleate Compared to Phenylephrine...
Heart RateBlood Pressure1 moreThis study will evaluate the safety of phenylephrine hydrochloride 10 mg + acetaminophen 500 mg + dimethindene maleate 1 mg compared to phenylephrine hydrocloride 10 mg alone in healthy volunteers.