Impact of Ranolazine on Myocardial Ischemia Detected by High-Field 3T Cardiovascular Magnetic Resonance...
AnginaHeart DiseaseEvaluation of use of ranolazine in patients with stable heart pain with cardiac magnetic resonance imaging (CMRI) and phosphorous-31 magnetic resonance spectroscopy (31P MRS). Subsequent testing using these modalities will show improved oxygen to the heart muscle.
Effectiveness New Health Care Organization Model in Primary Care for Chronic Cardiovascular Disease...
Ischemic Heart DiseaseThe purpose of this study is to determine whether a multifactorial primary care intervention based on chronic models can improve the level of control and reduce the number of hospital admissions in patients with ischemic heart disease.
Prospective Registry to Asses the Long-term Safety and Performance of the Combo Stent
Coronary Artery DiseasePatients with stenosis in one or more coronary artery are often treated with a percutaneous coronary intervention (PCI). As part of the PCI treatment a stent is often placed to keep the vessel open over time. The Combo-Stent is a novel stent for use during percutaneous angioplasty. In short, the Combo stent combines a drug eluting technique and an endothelial cell attracting layer. The drug coating is designed to prevent re-narrowing of the stent. The endothelial cell attracting layer is designed to ensure rapid coverage of the stent struts with vascular wall cells. The REMEDEE REGISTRY evaluates the long-term safety and performance of the Combo stent in routine clinical practice. In total 1000 patients will be registered and followed for five years.
Apposition Assessed Using Optical Coherence Tomography of Chromium Stents Eluting Everolimus From...
Coronary Artery DiseaseThe purpose of the trial is to directly compare the Cobalt Chromium platform everolimus-eluting stent, Xience Prime™, with the Platinum Chromium platform everolimus-eluting stent, Promus Element™, in relation to stent scaffolding shape, position with the heart blood vessel and extent of tissue coverage (at 6 months) using optical coherence tomography. Hypotheses: The alloy composition and strut design of a drug-eluting stent has a direct bearing on stent apposition measured using OCT. Stent design and alloy composition have a direct influence on radial support and scaffold shrinkage.
A Lead Rectangle to Lower the Operator's Radiation Exposure
AtherosclerosisCoronary Occlusion1 moreDuring fluoroscopic imaging, diagnostic information is carried in the primary beam. These high intensity X-rays are the chief hazard to the patient. Lower energy scattered radiation deviates in all directions from the patient. Despite typical precautions (i.e., hanging a lead shield between the patient and the operator), many operators will be exposed to high radiation dose (higher than the permitted 50 miliS per year), this long term radiation exposure may result in stochastic and deterministic effects. The purpose of this study was to test the hypothesis that a non disposable radiation protection drape (that will cover the lower part of the patient) could help minimize the radiation scattered from the patient to the operator. In a procedure done through the Radial approach, there is a large portion of the patients (from the umbilicus and down) that is a source of scatter radiation to the operator. This portion can be covered with a lead rectangle. A non disposable, lead drape of uniform thickness will be inserted into a sterile nylon bag and will be used during fluoroscopic and cineangiography coronary angioplasty procedures. The lead drapes will cover the femoral puncture site. The widths and length of the drape is 50-60cm and 100 cm respectively and was shown not to hinder the field of radiation needed for fluoroscopy and cineangiography. (The upper border of the lead is under the patient's umbilicus and was shown not to interfere with the radiation field needed for angiography or angioplasty). The Investigators anticipate that the study will show a significant reduction in radiation exposure and hence reduce the radiation hazard to the operator.
Late Stent Strut Apposition and Coverage After Drug-Eluting Stent Implantation by OCT in Patients...
Coronary Artery DiseaseCoronary Disease6 moreThe purpose of this study is to evaluate the incidence of late incomplete stent apposition (ISA) and un-coverage by optical coherence tomography (OCT) following everolimus-eluting stent (EES) with bioabsorbable polymer (SYNERGY™, Boston Scientific,Nattick, MA, USA) versus zotarolimus-eluting stent (ZES) with permanent polymer(Resolute Onyx™, Medtronic, Santa Rosa, CA, USA) implantation in patients with AMI at 12 months.
What is the Optimal antiplatElet and Anticoagulant Therapy in Patients With Oral Anticoagulation...
Atrial FibrillationsHeart Valve Prostheses5 moreThe optimal antithrombotic therapy for patients with atrial fibrillation (AF) with a CHA2DS2-VASc score ≥1 with concomitant acute coronary syndrome (ACS) or revascularisation by percutaneous coronary intervention (PCI) with stenting, is still unknown. For these patients current North American and European guidelines recommend a triple therapy strategy, including vitamin K antagonists (VKA), aspirin and clopidogrel. A major drawback of this triple therapy strategy is a significant increase in the risk of major bleeding. Furthermore, the ommitance of aspirin and the introduction of more potent P2Y12 inhibitors as well as the non-vitamin K oral anticoagulants (NOAC), created numerous new antithrombotic treatment strategies for these patients with overlapping conditions. To date, evidence on the risks and benefits of these new antithrombotic treatment strategies is lacking. The WOEST 2 Registry aims to improve medical care for patients with AF and/or a heart valve prosthesis ánd undergoing coronary revascularisation through a better understanding of their demographics, antithrombotic management and related in-hospital and long-term outcomes. The WOEST 2 Registry will provide data to support benchmarking of antithrombotic treatment patterns and patient outcomes. Objective: To assess the different management patterns and related in-hospital and long-term safety and efficacy outcomes of combined use of chronic oral anticoagulation and a P2Y12 inhibitor in patients with atrial fibrillation and/or a heart valve prosthesis undergoing coronary revascularisation.
MRI Sequence and Imaging Protocol Development
CardiomyopathyHypertrophic5 moreThe purpose of this study is to develop imaging protocols when using cardiovascular magnetic resonance (CMR) to assess cardiac functions, morphology and tissue characterization. The National Heart Research Institute Singapore (NHRIS) houses two dedicated CMR scanners to support the numerous investigator initiated projects in patients with various cardiac pathologists. By optimizing novel CMR sequences used in these studies, scanning time can be shortened for patients with underlying cardiac diseases.
Coronary Artery Disease: a Case- Control Study
Coronary Artery DiseaseAtherosclerosis is a chronic inflammatory condition, which is associated by the involvement of several pathological events, and alteration in the serum levels of pro- and anti-inflammatory, and lipid markers. The investigators evaluated the contribution of serum biomarkers levels to the pathogenesis of coronary artery disease, namely their association with risk factors, clinical presentation, extent and severity of atherosclerotic changes accompanying coronary artery disease.
Florida Cardiovascular Quality Network
Stable Ischemic Heart DiseaseFlorida Cardiovascular Quality Network Application of Clinical Decision Support Software Tools at the Point of Care in Patients with Stable Ischemic Heart Disease - a Quality Outcomes Registry