
Supralimus-Core™ Pharmacokinetic (PK) Study
Coronary Artery DiseaseThe primary objective of this study is to evaluate the pharmacokinetic (PK) and safety associated with Supralimus-Core™ Sirolimus Eluting Coronary Stent system in the treatment of single de novo lesions in native coronary arteries between 2.5 to 3.5 mm in diameter.

Comparison of Pitavastatin With Atorvastatin in Increasing High Density Lipoprotein - Cholesterol...
HypercholesterolemiaCoronary Artery DiseaseThe purpose of this study is to compare the effects of pitavastatin and atorvastatin on adiponectin percentage change in patients with hypercholesteremia comorbid stable CAD.

Safety and Efficacy of Aliskiren on the Progression of Atherosclerosis in Coronary Artery Disease...
Coronary Artery Disease (CAD)Coronary AtherosclerosisThe study will assess the change in coronary atherosclerotic disease as determined by intravascular ultrasound (IVUS) for aliskiren compared to placebo when given in addition to standard therapy in patients with coronary artery disease (CAD) and a blood pressure in the pre-hypertensive range.

Elixir Medical Clinical Evaluation of the Novolimus-Eluting Coronary Stent System: A Randomized...
Coronary Artery DiseaseRandomized Study To evaluate the safety and effectiveness of the Elixir Medical DESyne Novolimus-Eluting Coronary Stent System with Durable Polymer through the assessment of clinical, angiographic and IVUS endpoints as compared to the concurrently enrolled Medtronic Zotarolimus-Eluting Coronary Stent System in a randomized, single blind study of up to 200 male and female patients. In a Continued Access Registry of up to 100 patients receiving the DESyne Stent clinical-only endpoints will be evaluated. To evaluate the safety and effectiveness of the Elixir Novolimus-Eluting Coronary Stent System with bioabsorbable polymer as compared to the Medtronic Endeavor Zotarolimus-Eluting Coronary Stent System control through clinical and angiographic endpoints.

Reducing Risk in Cardiac Rehabilitation: Partners Together in Health (PaTH) Intervention Study
Coronary Heart DiseaseCardiac RehabilitationThe objective of the proposed study, using an experimental, two-group (n = 30 couples in each group) repeated measures design, was to pilot test the effects of the PaTH Intervention versus a usual care group in improving the following outcomes: a) physical activity and healthy eating behaviors, and b) functional capacity. The primary outcomes will be physical activity behavior (minutes per week) and eating behavior (percent saturated fat) at the 6 month time point in both the coronary artery bypass graft (CABG) patient and his/her partner. Secondary outcome includes functional capacity in patients and partners at 6 months.

EndocardialVascularEndothelialGrowth Factor D(VEGF-D)Gene Therapy for the Treatment of Severe Coronary...
Angina PectorisMyocardial InfarctionThe purpose of the study is to evaluate the safety and efficacy of catheter mediated endocardial adenovirus VEGF-D gene therapy in patients with severe coronary heart disease.

Scripps Evaluation of Antiplatelet Therapies for Intermediate Duration With the Endeavor Stent (Seaside)...
Coronary Artery DiseaseCoronary ThrombosisDespite the benefit of drug-eluting stents (DES) to reduce the need for repeat revascularization procedures, concerns regarding late stent thrombosis (ST) have led to recent guidelines advocating extended prescription of dual antiplatelet therapy (DAPT) with aspirin and a thienopyridine (clopidogrel or ticlopidine]) beyond that described in the product labeling. Specifically, an advisory has recommended at least 1 year DAPT following treatment with DES in patients without contraindications. However, this recommendation was largely empiric and not based on any trial showing reductions in ST with long-term DAPT, nor are potential safety differences between DES considered. Further, no study has examined the balance in potential efficacy with long-term DAPT relative to an increased bleeding risk. A consistency across clinical trials involving the Endeavor DES has been very low rates of late myocardial infarction, cardiac death and ST. Unlike other DES, recent studies indicate that the Endeavor stent may permit more rapid and complete healing over stent struts in addition to restoring normal blood vessel function. Further, in patients treated with the Endeavor stent, long-term safety outcomes are similar through 3 years follow-up irrespective of whether patients were adherent to DAPT for durations of ≤ 6 months, 12 months or 24 months. In this study, long-term safety and effectiveness will be examined for patients treated with the Endeavor stent and assigned to DAPT for reduced duration of 6 months. If the study demonstrates safety and efficacy, it could influence treatment guidelines in favor of an abbreviated duration of DAPT for patients treated with the Endeavor stent. This would mean that should a bleeding complication or need or surgery arise less than 12 months post-PCI, patients treated with the Endeavor stent could stop DAPT after 6 months with reasonable estimate of safety. Furthermore, it is possible that patients who are currently denied DES due to known need for elective surgery could be treated with the Endeavor stent in cases where surgery can be temporarily delayed. Finally, it could be an additional option for patients who forgo treatment with DES in favor of bare metal stent (BMS) out of fear of possible bleeding with long-term DAPT. Finally, it is recognized that not all patients respond the same way to anti-platelet therapy. Recent studies have indicated that inherited genetic variations in the way the body metabolizes anti-platelet medications may be important determinants of responsiveness to thienopyridine therapy, and that such differences may also confer a higher likelihood of adverse outcome. Patients agreeing to the additional genetic sub-study will have a DNA sample taken at baseline to test for the presence of such genes related to antiplatelet therapy metabolism and effectiveness. The results of these tests could help the medical community to better understand individual variation in response to anti-platelet therapy and the role that genetics may play in determining the response. It is possible that the information gained could help physicians tailor DAPT on a patient by patient basis.

Darusentan Effect on PET Uptake Heterogeneity
Coronary Artery DiseaseEndothelial DysfunctionThe primary objective of this study is to test the hypothesis that myocardial perfusion heterogeneity, quantified by Markovian Homogeneity analysis of cardiac PET perfusion images, will improve in a quantitative manner after treatment with selective ETA receptor antagonist darusentan 100 mg per day for 2 weeks compared to baseline and post-treatment PET scans in clinically stable subjects with coronary atherosclerosis and/or risk factors.

A Study of the Effect of RO4607381 on Atherosclerotic Plaque in Patients With Coronary Heart Disease...
Coronary Heart DiseaseThis study will assess the effect of RO4607381, compared to placebo, on atherosclerotic plaque in patients with coronary heart disease (CHD) including patients with other CHD risk factors. After a pre-randomisation period during which positron emission tomography computed tomography (PET/CT) and MRI will be conducted, patients will be randomized to receive either RO4607381 600mg po daily, or placebo po daily. PET/CT and MRI scans will be taken at intervals during the study. The anticipated time on study treatment is 2 years, and the target sample size is 100 individuals.

A Study Assessing the Effect of RO4607381 on Vascular Function in Patients With Coronary Heart Disease...
Coronary Heart DiseaseThis study will assess the safety, tolerability and efficacy of RO4607381 in patients with coronary heart disease (CHD) or CHD risk equivalents. Patients will be randomized to receive either RO4607381 600mg po daily or placebo po daily. Endothelial function will be measured by flow mediated dilatation and blood pressure monitoring will be assessed. The anticipated time on study treatment is up to 12 months, and the target sample size is up to 500 individuals.