iDropper Usability in Glaucoma
GlaucomaOpen-Angle [C11.525.381.407]The purpose of this study is to evaluate the usability of a medication management support system for glaucoma patients self-administering eye drops named iDropper. The iDropper system is a home-based ocular medication management system that reminds, instructs, dispenses, and records eye drop medication usage. The iDropper system will be evaluated among a cohort of glaucoma subjects self-administering eye drops for 4-weeks.
Effects of Netarsudil and Timolol on Retinal Blood Vessel Density and Visual Acuity
OAG - Open-Angle GlaucomaOHT - Ocular HypertensionThe purpose of this research study is to compare the effect of Netarsudil and Timolol on eye pressure and blood vessels of the back of the eye.
The Effects of Cosopt® Vs Xalacom® on Ocular Hemodynamics and Intraocular Pressure (IOP) in Primary...
Open-Angle GlaucomaOcular HypertensionBoth Cosopt® and Xalatan® plus Timoptic® will significantly lower IOP, however only Cosopt® will demonstrate positive hemodynamic effects. The clinical significance of this will be investigated by examining the ophthalmic and short posterior ciliary arteries to determine the blood supply to the optic nerve head, the site of damage in glaucoma
IOP Fluctuations in Primary Open Angle Glaucoma Patients Before and After Deep Sclerectomy
Primary Open Angle GlaucomaPrimary open angle glaucoma (POAG) is associated with inadequate drainage of the aqueous humor via the trabecular meshwork through the Schlemm's canal towards the systemic circulation. This may lead to an increase in IOP and may damage the optic nerve. The purpose of glaucoma management is to lower IOP in order to prevent progression of the optic neuropathy and subsequent visual loss. Firstline treatment usually includes IOP-lowering drug therapy. However, if IOP remains uncontrolled and/or the optic nerve damage progresses despite controlled IOP, surgery may be indicated. Deep sclerectomy (DS) is a non-penetrating surgical procedure for the treatment of open angle glaucoma that allows the enhancement of the aqueous outflow by removing part of the inner wall of Schlemm's canal and trabecular meshwork. DS was shown to achieve a good control on IOP over the long term. The purpose of this study is to assess the 24-hour IOP fluctuation profile recorded with Triggerfish in patients with POAG before and after DS.
The Expression of Matrix Metalloproteinase 13, Tissue Inhibitor of Metalloproteinases 3, and Calcium-sensing...
Open-angle GlaucomaThis study was to assess the distinct expression of matrix metalloproteinase 13,tissue inhibitor of metalloproteinases 3, and calcium-sensing receptor, in human trabecular meshwork between normal and glaucomatous eyes.The expressions of matrix metalloproteinase 13, tissue inhibitor of metalloproteinases 3 and calcium-sensing receptor in the trabecular meshwork tissues were examined by streptavidin-peroxidase immunohistochemical staining method and western blot, and histological changes of trabecular meshwork were studied by Hematoxylin and Eosin staining.
Computer-aided Diagnosis of Ocular Diseases Based on Corneal Biomechanics
Corneal EctasiaCorneal Disease5 moreThe purpose of this study is the investigation of biomechanical properties of the cornea using computer-aided data analysis. Currently, it is known that keratoconus and glaucoma are ocular disease that are associated with biomechanical alterations of the cornea. Corneal ectasia, especially keratoconus, is a corneal disease that leads to an irreversible loss of visual acuity while the cornea becomes steeper, thinner and irregular. For these patients, surgical intervention (e.g. corneal cross-linking) is performed, in case of disease progression. In glaucoma, the information about corneal alterations serves in two ways, first, correct measurement of intra ocular pressure (IOP); second, early diagnosis of suspects before visual field defects are detectable. Especially, the Corvis ST is an air-puff tonometer that measures intraocular pressure, corneal thickness (CCT) as well as dynamic corneal response (DCR) parameters. Most of the DCR parameters are affected by IOP and CCT: Therefore, algorithm are needed to determine parameters without impact of IOP and CCT that are describe the biomechanical properties of the cornea.
Diurnal and Nocturnal Effect of Travatan With SofZia Preservative on Intraocular Pressure and Ocular...
Open Angle GlaucomaOcular HypertensionThe purpose of this research study is to determine the diurnal and nocturnal effects of Travoprost with SofZia (Travatan Z) on intraocular pressure and ocular perfusion pressure.
Lumigan® in Patients With Primary Open Angle Glaucoma (POAG) or Ocular Hypertension (OHT)
GlaucomaOpen-Angle1 moreThis is an observational study of Lumigan® 0.01% (bimatoprost) treatment in clinical practice for patients with Primary Open Angle Glaucoma (POAG) or Ocular Hypertension (OHT).
Dry Eye and Irritation Comparison of Latanoprost With the Preservative Versus Travoprost Without...
Ocular DrynessOcular Irritation2 moreAlthough Benzalkonium chloride (BAC) has been used as a preservative for many years, many studies have demonstrated that prolonged use of topical ocular medications preserved with BAC may exacerbate sequelae associated with ocular surface disease. These effects could lead to the induction of subclinical inflammation,1 reduction of corneal epithelial barrier function, 2, 3 destabilization of the tear film, 4 cataract formation, 5 and an overall higher incidence of patient complaints of dryness and irritation. 4-6 This study will compare the efficacy of travoprost 0.004% without benzalkonium chloride (BAC) to that of the marketed formulation of latanoprost 0.005%with BAC in patients with dryness and irritation and open-angle glaucoma or ocular hypertension. A double blind comparison will be used to assess whether those two different formulations will affect the tear breakup times, corneal staining, and baseline tear secretion tests in patients that are already taking latanoprost regularly with complaints of dryness and irritation. Patients included in the study will be given two bottles, one labeled for their right eye and the other for their left eye. Each pair of bottles will be identical in appearance and randomized with either latanoprost or travoprost and each pair will be assigned a number to aid in future analysis of the final results.
Results of Ocular Compression and Suture Release in Trabeculectomy and Combined Surgery
Primary Open Angle GlaucomaThe use of ocular compression and suture release have helped to improve the safety and decrease the risks of glaucoma filtering surgery. This study looks at the decrease in intraocular pressure and glaucoma medications required following glaucoma filtering surgery.