search

Active clinical trials for "Hypotension"

Results 681-690 of 875

Cerebral Circulation in Critically Ill Children

Arterial HypotensionShock1 more

The principal purpose of this study is to describe the changes in cerebral circulation (assessed by transcranial ultrasound) and oxygenation (assessed by Near InfraRed spectroscopy, NIRS) during resuscitation for hemodynamic failure (arterial hypotension or shock) in critically ill children treated with vasoactive or inotropic drugs. The secondary objectives are : i) to evaluate the association between an alteration of cerebral circulation and/or oxygenation and an alteration in macro-circulatory parameters (Mean Arterial Blood Pressure and cardiac output) or a bad outcome, ii) to study if cerebral autoregulation is impaired

Completed7 enrollment criteria

Norepinephrine Versus Ephedrin for Prevention of Post Spinal Anesthesia in Cesarean Section

Maternal Hypotension SyndromeCesarean

Spinal anesthesia is still the gold standard anesthetic method for elective and urgent cesarean section, the post spinal hypotension remains the most frequent complication of this procedure and is still responsible of considerable maternel and fetal morbidity. It is recommanded to prevent this post spinal hypotension with fluid coloading and prophylactic vasopressors administration. The aim of this study is to compare the efficency and the safety of norepinephrin and ephedrin prophylactic administration to reduce the incidence of post spinal hypotension in cesarean section.

Unknown status6 enrollment criteria

Non Invasive Haemodynamics in Neuraxial Anaesthesia Hypotension

HypotensionControlled3 more

Spinal (or neuraxial) anaesthesia is still considered the first choice technique for elective Caesarean section as simple, quick, reliable and cheap. However, this anaesthetic method can be burdened by maternal hypotension with significant maternal and foetal implications.

Completed19 enrollment criteria

Physiological Validation of Current Machine Learning Models for Hemodynamic Instability in Humans...

Hypotension and Shock

This study will be collecting data on participants undergoing lower body negative pressure (LBNP) to simulate progressive blood loss. The goal of the study is to collect data to allow for development of an algorithm with machine learning to predict blood pressure responses to hyporvolemia by analyzing the arterial waveforms collected during LBNP.

Completed4 enrollment criteria

Can Right Toe Perfusion Index or Pleth Variability Index Predict Spinal Anesthesia Induced Hypotension?...

Cesarean Section ComplicationsHypotension3 more

Spinal anesthesia for caesarean section is associated with a decrease in systemic vascular resistance and cardiac output and may cause hypotension in a significant portion of the parturients. Hypotension during delivery may cause maternal and fetal complications. If parturients who are likely to develop hypotension after spinal anesthesia can be identified before surgery, anesthesiologists would have opportunity to take measures such as prophylactic vasopressor administration. Perfusion index (PI) measured by pulse oximetry reflects vasomotor tone which affects the degree of hypotension after spinal anesthesia. This is a non-invasive method of assessing the relative vascular tone with the use of pulse oximeter which calculates the ratio of pulsatile versus the non-pulsatile component of the blood flow. A lower PI indicates greater peripheral vasomotor tone. Pleth variability index (PVI) is calculated using maximum and minimum values of perfusion index during respiratory cycles. PVI is one of the dynamic indices that can predict fluid responsiveness. There are several studies investigating the predictive value of finger PI and PVI on hypotension after spinal anesthesia. However the aortocaval compression by the gravid uterus directly effects the lower extremity perfusion. So, in this study we aimed to investigate whether the right toe PI and PVI values at supine and left lateral positions can predict hypotension during caesarean section.

Completed9 enrollment criteria

Ivabradine Versus Propranolol for Induced Hypotension in Endoscopic Sinus Surgery

Hypotension

the study is designed to compare the effect of addition of oral Ivabradine, propranolol to general anesthesia aimed reduction in blood loss during functional endoscopic sinus surgery.

Unknown status6 enrollment criteria

The VISION-Acute Study

HypertensionHypoxia1 more

AIM: We propose an innovative approach using Lifelight® smart technology that will enable the continued provision of high level patient care at the same time as reducing pressure on nursing and equipment resources. METHOD : Lifelight® is a computer program ("app") which can be used on smart devices that contain a camera. It is able to measure all of the vital signs by measuring very small changes in skin colour that occur each time the heart beats. This means that it does not need to touch the patient. We believe this could be an effective way of measuring vital signs, especially during the COVID-19 pandemic when prevention of cross-contamination between patients is essential. Patients are also likely to be reassured by a contactless approach. During this study, we will recruit two groups of people who are hospitalised with an acute illness. The first group will be people expected to have abnormal blood oxygen levels such as those with acute respiratory problems including those with COVID-19. The second group will be people expected to have abnormal blood pressure. These Lifelight vital signs will be compared to measurements from standard clinical equipment. The exact number of participants recruited will depend on how quickly the app "learns" and how many of the vital signs collected are outside of the normal range. For the first group of participants, we will use a camera to collect data about the changes in their face and use this to teach the app how to measure blood oxygen level and also to check how well the app measures blood oxygen level, heart rate and respiratory rate. For the second group of participants, we will use a camera to collect data about the changes in their face to check how well the app measures blood pressure and respiratory rate. All of the data will be kept secure and participants will not be able to be identified.

Completed5 enrollment criteria

Evaluation of Fluid Volume in Patients With Refractory Hypotension (Fresh-ER)

Undifferentated Shock

The objective of the study is to observe the change in hemodynamic variables (i.e. CO, SV, HR, SV) as assessed during rapid fluid bolus.

Completed27 enrollment criteria

MediBeat - HeartBeat Observation Trial

Low Blood PressureBlood Pressure3 more

The goal of the study was to compare the current gold standard blood pressure instrument (a mercury-filled sphygmomanometer with cuff and stethoscope) with the new experimental algorithm developed by HeartBeat Technologies Ltd. To that end, participants were recruited from Markham, Ontario and participated in a series of alternating blood pressure measurements over a period of 45 minutes. Comparisons were made between manual measurements and device measurements to determine the quality of the device readings. Measurements were taken by trained nurses and staff were consistent across the study duration.

Completed6 enrollment criteria

Optimizing Fluid Status

Hypotension During Dialysis

Title of study: Optimizing Fluid Status Study code: HD-IIT-01-E Study design: Prospective open design in study centre at two locations Applied medical device: Body Composition Monitor (BCM) for determination of fluid overload and dry weight Aim of the study: To improve the fluid status in chronic HD patients (measured as OH (overhydration) or TAFO (time averaged fluid overload)) based on BCM measurements. Up to now, the BCM was occasionally applied in both locations of the study centre. Study hypothesis: Regular measurement of fluid status (assessed by BCM) and display of dry weight (post-weight plan)will have significant consequences, namely a decrease of the: time averaged fluid overload (TAFO), proportion of patients with severe overhydration OH > 2.5 L,or OH/ECW > 15 %) proportion of dehydrated patients (OH < -1.0 L, or OH < -7 %), mean overhydration, variance of overhydration, time outside the reference range (-1.0L < OH < 2.5L). Devices used in this study: Dialysis machine 5008 equipped with Blood Pressure Monitor BPM, Blood Volume Monitor BVM, Blood Temperature Monitor BTM, and Online Clearance Monitor OCM ; Body Composition Monitor BCM ; Data management software / database system NephroLink Disposables used in this study: BVM blood lines and BCM electrodes Patients: 60 patients

Completed13 enrollment criteria
1...686970...88

Need Help? Contact our team!


We'll reach out to this number within 24 hrs