Retrospective Clinical Investigation of the Safety and Performance of 640PM Trifocal IOL Implantation...
CataractPresbyopia3 moreThe clinical investigation objective is to evaluate safety and performance outcomes of trifocal IOL implantation to improve vision in patients with cataract and/or ametropia (hyperopia, myopia) and/or presbyopia. Retrospective data from preoperative status up to 12 month postoperative status will be collected from patients that were implanted with Medicontur's 640PM intraocular lens: Preoperative status: Preoperative Screening and Baseline Surgery: IOL implantation M1: 1 month +/- 2 weeks postoperative follow-up M3: 3 months +/- 1 month postoperative follow-up M12: 12 months +/- 3 months postoperative follow-up
Evaluation of the Active Sentry System During Cataract Surgery With the Centurion Phacoemulsifier...
Cataract SurgeryEach new generation of phacoemulsification system has aimed to optimize the control of fluidics and the delivery of energy during phacoemulsification. Nicoli CM et al., (J Cataract Refract Surg 2016;42:157-162) suggested a better anterior chamber stability when using an active fluidics system. Malik PK et al., (Eye and Vision 2017;4:22) showed that using an IOP based phacoemulsification system in association with the use of an Intrepid balanced tip provides a reduction in CDE (Cumulated Dissipated Energy and EFU (Estimated Fluid Usage). It has also been shown that a lower CDE provides obvious benefits: less endothelium cells damages and lower complication rates (Mady MA et al., Clin.Ophthalmol. 2012; 6:503-10). The latest technologies, i.e. the Active Sentry Handpiece and Hybrid tips, have been introduced to further improve the safety of phacoemulsification. The Active Sentry system has moved pressure sensors closer to the operated eye, hence further reducing the risk of surge during procedures. (Thorne A et al. Phacoemulsifier occlusion break surge volume reduction, J Cataract Refract Surg. 2018;44:1491-1496). The Hybrid tips have been designed to prevent posterior capsule rupture in the event of contact with the capsule. This new technology allows phacoemulsification procedures under reduced infusion pressures and a "high-vacuum - low energy" strategy which may lead to a safer procedure. Data from this study will try to demonstrate that cataract surgeries with Active Sentry will need less CDE and therefore may be safer, due to the surge effects decrease. This CDE parameter will be analysed according to differents subgroups: Presence of hybrid tip or balanced tip, cataract score based on the WHO nuclear grading recommendation (Thylefors B et al., (2002) The WHO Cataract Grading Group, Ophthalmic Epidemiology, 9:2, 83-95) The recent experiences conducted in real world condition in different sites have suggested that Centurion with AS was able to improved settings: maximum vacuum and UltraSound (US) time reduction and as a consequence a 20 to 30% CDE reduction.
PMCF Retrospective Study Outcomes of a Monofocal Toric Intraocular Lens
CataractLens Opacities1 moreThis is a monocentric retrospective, open-label clinical study in patients after unilateral or bilateral implantation of hydrophobic acrylic monofocal toric intraocular lens PODEYE TORIC and executed only with standard of care examinations. The investigational device is CE approved. The investigational device and all study products, including the devices used for the study examinations, have been used within the intended use specifications from the manufacturer. In addition, there were no invasive or other burdening examinations. The investigator is an accredited and experienced cataract surgeon and researcher. The primary endpoint is to determine rotational stability in a minimum of 120 eyes of patients with PODEYE TORIC IOL implantation after cataract surgery. Patients will be enrolled for the documentation and evaluation of retrospective data up to 6 months postoperatively.
Effect of 1.8-mm Steep-axis Clear Corneal Incision on the Posterior Corneal Astigmatism in Candidates...
Cataractwe aimed to analyze the effects of cataract surgery using a 1.8-mm steep-axis clear corneal incision (CCI) on the posterior corneal surfaces based on the keratometry from the rotating Scheimpflug imaging device (Pentacam HR) in candidates for toric intraocular lens (IOL) implantation
Evaluation of a Trifocal Lens
Cataract SenileEvaluation of the clinical safety and effectiveness of hydrophilic acrylic intraocular lens
Post Approval Study of the AcrySof® IQ Toric Intraocular Lens (IOL) Models SN6AT6-SN6AT9
CataractsAstigmatismThe purpose of this study is to evaluate the use of toric high cylinder power intraocular lenses in a larger population in clinical practice and assure the continued safety of these approved devices.
Randomized, Masked Comparison of Bromfenac and Besifloxacin BID With Either Prednisolone BID or...
PseudophakiaCataract SurgeryThe purpose of this study is to determine if Lotemax eye drops are at least as effective as Pred Forte eye drops, which are the standard of care after cataract surgery.
Therapeutic Variables in Cataract Surgery
Cataract SurgeryThe purpose of this study is to compare patient outcomes in following cataract surgery in patients randomized to one of two surgical kits.
The Effect of Ranibizumab on Eye Lens Opacity in Cases With Age-Related Macular Degeneration
Age-Related Macular DegenerationCataractPurpose To evaluate the cataractogenic effect of intravitreal ranibizumab with the use of Lens Opacity Classification System III (LOCS III). Settings Cases with a diagnosis of wet AMD were included in this university practice based prospective study. Methods All cases had monthly injections of intravitreal ranibizumab in the first 3 months; subsequently an OCT-guided pro re nata injection regimen has been adopted. All cases had a comprehensive eye examination and LOCS III evaluation at baseline and 1, 3, 6 and 12 months after the initial injection. Examination outcomes and change from baseline in LOCS III grades at 12 months were recorded. Results Eighteen eyes of 13 cases (7 female, 6 male) were included in this study. The mean age at the baseline was 75,3 + 6,6 years. A mean of 3,4 + 0,7 injections were given on each eye. Mean follow-up was 13,83 + 2,33 months. Baseline mean visual acuity improved from 1,04 + 0,10 logMAR units to 0,76 + 0,26 logMAR units after 3 injections (P < 0.05). At the 12th month of follow-up mean visual acuity was 0,71 + 0,27 logMAR units. According to LOCS III grades none of the cases had a prominent change in nuclear color, nuclear opalescence, cortical and posterior subcapsular opacification throughout the follow-up. IOP remained stable at all follow-up points. No complications were recorded throughout the study. Conclusion Intravitreal ranibizumab is an efficient treatment in wet AMD. Results of LOCS III assessments in this pilot study suggest that intravitreal ranibizumab has no effect on the progression of lens opacity.
Pilot Study: Dynamic Light Scattering Device for Studying Early Changes in Cataract
CataractThis study will use a new dynamic light scattering device (DLS), developed jointly by NASA and the NEI, to study pre-senile cataracts (cataracts that develop in patients 55 years old or less). Cataract is a clouding of the lens that interferes with the passage of light to the retinal, impairing visual acuity. DLS uses a low intensity laser light (similar to that used in supermarket checkouts) to measures lens cloudiness. It detects changes in the human lens at the earliest molecular stages of cataract development, when anti-cataract treatment would be most effective in reversing, delaying or preventing cataract formation. Patients 55 years of age or younger with cataract may be eligible for this study. Candidates will be screened with the following tests and procedures: Medical history and physical examination. Eye examination, including measurement of visual acuity (vision chart) and eye pressure; examination of pupils and eye movements; dilation of the pupils for examination of the lens and the back of the eye (retina). Cataract photography using a camera with a bright flash to assess the status of the cataract and evaluate future changes. Blood drawing if necessary for clinical care. Participants will have a standard eye examination, as described above, plus DLS testing. For this procedure, the patient sits in front of the DLS device, with the chin placed on a chin rest. He or she fixes on a yellow-green target in the center of the camera lens. When the eye is properly aligned, the measurement is taken and the reddish light on the side of the camera lens turns on for 5 seconds. Measurements are taken on three layers of the lens. The procedure takes less than 30 minutes. Participants will be followed at the NIH clinic once a month for up to 1 year to follow progression of the cataract. The visits will include a repeat of some of the exams listed above.