Safety and Efficacy of Intracameral Zimoxin for Prevention of Endophthalmitis After Cataract Surgery...
EndophthalmitisIntracameral injection of 0.1% moxifloxacin solution after cataract surgery to prevent endophthalmitis
Controlled Sedation for Cataract Surgery
Failed Conscious Sedation During ProcedureThis study evaluates the surgeon and patient´s satisfaction who undergoes cataract surgery using either dexmedetomidine or remifentanil as sedation
Endothelial Cell Loss After Cataract Surgery
CataractsThe purpose of this study is to compare two cataract surgical technique variations for removing the nucleus of the lens (central part of the lens) in terms of damage to the inner layer of the cornea which is called the endothelium. One variation uses more ultrasound energy and the other more mechanical force to break up the nucleus.
Study to Optimize the IOL Constant of a New Multifocal Intraocular Lens
Cataract SenileProspective, non-comparative, multicenter study on medical device with 6 months follow-up.
User Acceptability Evaluation of Pseudophakic Patients Previously Implanted With the TECNIS Odyssey...
CataractsProspective collection of data from medical records, multicenter, post-market clinical follow-up study.
Visual Function and Patient Satisfaction in Glaucoma or Ocular Hypertensive Patients Undergoing...
LensesIntraocular1 moreNew extended depth of focus intraocular lenses (IOLs) are being used in a broader spectrum of patients than trifocal IOLs. The purpose of this study is to evaluate visual improvement after cataract surgery in patients with glaucoma or ocular hypertension undergoing simultaneous cataract surgery with i-Stent implantation with the implantation of a Vivity IOL. Results will be compared with a group of glaucoma or ocular hypertension undergoing isolated cataract surgery with Vivity implantation, as well as with patients with no pathology undergoing cataract surgery and Vivity implantation
Visual Outcomes After Bilateral Surgical Cataract Phacoemulsification: AcrySof Toric IOL Implantation...
CataractThe objectives of this study are to assess and compare bilateral uncorrected distance visual acuity and distance spectacle independence post bilateral implantation of AcrySof Toric Intraocular Lenses (IOLs) and monofocal IOLs. Secondary outcomes will include cost of eyeglass purchased and patient vision-related quality of life.
Observational, Prospective Clinical Investigation on Mini 4 Ready Intraocular Lens
CataractCataract surgery presents an extremely high success rate in improving vision and quality of life and it is currently the most commonly performed ophthalmic surgery, especially considering its growing utility in the aging population (e.g., more than 20 million worldwide underwent the procedure in 2015); it is possible to affirm that benefits clearly outweigh risks. However, although cataract surgery is highly effective and relatively safe, owing to the enormous numbers, even uncommon surgical complications could potentially harm the patients. For this reason, it is essential to continue to consider the possible risks and undesirable side-effects associated to cataract surgery, such as post-cataract endophthalmitis (POE), postcataract opacification (PCO), PCME, dysphotopsias, retinal detachment, and IOL dislocation.
Comparative STudy of the ARGos Biometer Compared to UltraSound Biometer in B-mode in Case of Measure...
CataractBiometry has become one of the most important steps in modern cataract surgery. The axial length of the eye may be measured by ultrasound (either contact or immersion) or by optical means. Non-contact optical biometry has become the gold-standard because of its ease of use, accuracy, and reproducibility. However, the main disadvantage of the optical methods is their inability to obtain axial length measurements in approximately 10% of eyes, typically those with dense posterior subcapsular cataracts. By Using SS-OCT device, it has been reported that the AL measurements cannot be made in 0.6 to 7.4% of cases . Therefore, measurement by US biometer is still necessary for advanced cataract. The ultrasound measure the LA between the corneal epithelium and the vitreomacular interface. Ultrasound in B mode (or Brilliance) with the help of the control vector allows a 2-dimensional control of the plan used for measurement. This method is used in current practice in our centers when LA measurements is not possible with our optical SS-biometer. Recently Alcon has integrated the ARGOS® biometer's diagnostic testing with Alcon's Cataract Refractive Suite technologies. ARGOS® is a non-invasive, non-contact biometer based on swept-source optical coherence tomography (SS-OCT). The device is intended to acquire ocular measurements as well as perform calculations to determine the appropriate intraocular lens (IOL) power and type for implantation during intraocular lens placement. ARGOS® measures the following 9 parameters: Axial Length, Corneal Thickness, Anterior Chamber Depth, Lens Thickness, K-values (Radii of flattest and steepest meridians), Astigmatism, White-to-White (corneal diameter) and Pupil Size. The Reference Image functionality is intended for use as a preoperative and postoperative image capture tool. ARGOS® includes an operation mode for when the retina is hardly or not visible at all denominated the "Enhanced Retinal Visualization mode" (ERV) that allows, in most cases, visualization of the retina. This signal in the retinal region is enhanced by shifting the coherence function (Argos Users manual). In a prospective observational study conducted in 2 centers in USA involving 107 eyes, they have evaluated the repeatability and reproducibility of ARGOS® measurements in comparison with IOLMaster®500 and LENSTAR LS 900. They have shown that the AL acquisition rate was higher with ARGOS® (96%) compared with both LENSTAR LS 900 (79%) and IOLMaster®500 (77%). The reason was that ARGOS® was more successful at measuring AL in eyes with dense cataract.
The Long-term Outcome After Toric Intraocular Lens Implantation
Corneal AstigmatismCataractCorneal astigmatism is refractive error that impairs uncorrected visual acuity. When patients undergo cataract surgery, implantation of toric IOL is deemed the most effective choice for correcting corneal astigmatism and reducing postoperative spectacle dependence. Previous studies report that the visual effects and rotational stability of toric IOLs are well maintained over 1- or 2-year follow-up periods. However, the long-term changes in the effects of toric IOLs remain unclear.