The Effect of IV PAPAVERINE 80 mg Prior to Catheter Balloon Insertion on Bishop Score and Pain
Induction of LaborPain3 moreThe cervix consists of connective tissue, smooth muscle, and parasympathetic innervation. Smooth muscle makes up about 15% of the cervix, is mainly found under the internal opening of the neck. Papaverine and its derivatives are musculotropic antispasmodic drugs that directly affect smooth muscle, the mechanism is to reduce the spasm of smooth muscle resulting in relaxation. Studies on the pharmacokinetics of this drug show that it has a half-life of 0.5-2 hours and its effect is apparent within 10 minutes. Administration of antispasmodic drugs during childbirth is common in developing and developed countries. Based on previous studies, the use of these drugs during childbirth may lead to a faster opening of the cervix. Possible uses of Papaverine include, administered separately or in combination with other treatments such as rupture of amniotic membranes and/or Oxytocin administration. According to some studies, administration of Papaverine at birth can be used as a preventive or therapeutic strategy in cases of prolonged labor or first stage over 12 hours as defined in some studies. According to Kochran et al, who included 13 experiments with 1995 participants, the use of antispasmodic drugs shortened the first stage of labor by an average of 74.34 minutes. In 6 experiments that included 820 patients, the administration of antispasmodic drugs during labor increases the rate of cervical opening by an average of 0.61 cm per hour. In addition to the muscle relaxation effect, studies have been published on the analgesic effect of PAPAVERINE for example in patients with urinary stones. In the present study, the investigators want to test the effect of administering PAPAVERINE IV 80 mg within half an hour before the insertion of a catheter balloon for cervical ripening on the Bishop score after catheter removal between the two groups.
Comparing Effectiveness of CSE Versus DPE for Labor Analgesia
Labor PainThe primary purpose of this study is to determine if there are differences in block quality between the CSE and DPE techniques for labor analgesia in parturients in active labor. We hypothesize that when compared to the CSE technique, the DPE technique will significantly improve block quality in this population and require fewer "top-ups" and catheter replacements.
Optimum Length of Catheter in the Epidural Space for Labor Analgesia in Non-obese Women: a Randomised...
Labor PainEpidural analgesia was introduced to the world of obstetrics in 1909 by Walter Stoeckel. Over the following 100 years it has developed to become the gold-standard for delivery of intra-partum analgesia, with between 60 and 75% of North American parturients receiving an epidural during their labor. Effective labor analgesia has been shown to improve maternal and fetal outcomes. One aspect of catheter insertion that has not been fully evaluated, and with very little recent work undertaken, is the optimal length of epidural catheter to be left in the epidural space. Dislodgement or displacement of epidural catheter remains a significant cause for failure with analgesia. Novel methods of fixation may further reduce the risk of catheter migration. Another factor is the direction of travel within the epidural space, only 13% of lumbar catheters remain uncoiled after insertion of more than 4 cm into the epidural space. Hypothesis: The investigators hypothesize that catheters inserted to 4 cm will have a lower rate of failure when compared to those inserted to 5 cm. Objective: This study aims to evaluate the difference in quality of labor analgesia delivered by epidural catheters inserted to either 4 or 5 cm into the epidural space. This study will be conducted as an interventional double-blinded randomised control trial to establish best practice.
ED90 of Epidural Bupivacaine With Lidocaine for the Initiation of Labor Analgesia
Labor PainAnalgesiaTo estimate the dose of bupivacaine required to achieve initial effective comfort in 90% of patients (ED90) via the epidural (DPE or EPL) technique in women undergoing labor after receiving a lidocaine "test dose"
Effectiveness of Programed Intermittent Epidural Bolus Interval 90 (EI90) of 10 ml, 0.0625% Bupivacaine...
Labour PainMultiple studies showed the numerous advantages of implementing programmed epidural bolus (PIEB) technique, where a fixed volume of local anesthetic is automatically administrated at a set time interval compared to the continuous epidural infusion technique (CEI). The advantages were improved maternal satisfaction, decreased local anesthetic consumption, and decreased second stage of labor.The theory behind PIEB is that to attain a more uniform spread of local anesthetic in the epidural space a higher volume of injectate and a higher pressure is needed.Different approaches using different timings and volumes for PIEB have been proposed to achieve the optimal regimen. Many studies showed evidence that 10 mL boluses of bupivacaine 0.0625% with fentanyl 2 μg/mL delivered every 40 min, named effective programed intermittent epidural bolus interval 90 (EI90), produced effective analgesia without breakthrough pain in 90% of nulliparous women during the first stage of labor.
Virtual Reality Compared to Nitrous Oxide for Labor Analgesia
Labor PainThe purpose of this study is to determine if non-invasive distracting devices (Virtual Reality headsets) are non-inferior to conventional therapy (nitrous oxide) for addressing maternal needs during labor who desire non-epidural pain relief.
Dural Puncture Epidural VS Standard Epidural on Physician Top-ups During Labour Analgesia
Obstetric PainLabor Pain1 moreThe purpose of this prospective randomized controlled study is to compare the number of physician top-up interventions during the first stage of labour between two different neuraxial analgesia techniques : the dural puncture epidural and the standard epidural.
Programmed Intermittent Epidural Bolus Versus Continuous Infusion in Labour Analgesia
Labor PainThis study aims to establish if programmed intermittent epidural bolus combined to patient controlled analgesia in labour analgesia will lower the hourly bupivacaine consumption when compared to continuous infusion combined with patient controlled analgesia. The investigators' hypothesis is that the use of programmed intermittent epidural bolus will lower the hourly bupivacaine consumption.
Development of Variable Volume Automated Mandatory Boluses for Patient-controlled Epidural Analgesia...
Labor PainBreakthrough PainA novel epidural delivery regimen was developed: Variable volume automated mandatory bolus (AMB) (VVAMB) will advance individualisation of labour epidural analgesia, by which a larger volume of bolus may contribute to better spread of the local anaesthetics within brief period and thereby reduces the chances of motor blockade that could reduce instrumental deliveries.
Evaluation of Objective Pain Measurement Device
PainAnalgesia1 moreThis study will attempt to objectively measure pain with an experimental device. The investigators will apply the device to measure patients "pain" due to uterine contractions during routine clinical care to correlate patients verbal pain ratings and analgesia requirements to that measured by the device. A brain oxygenation device, Edwards Foresight, will be used to concurrently to monitor brain oxygenation and hemodynamics, so the relationship between the CereVu ROPA device objective measure of pain and brain oxygenation/hemodynamic changes and patient-reported pain can be determined.