Patent Foramen Ovale (PFO) Closure at the Time of Endovascular Cardiac Electronic Device Implantation...
Foramen OvalePatentParticipants enrolled in this study will have been diagnosed with patent foramen ovale (PFO) and have been scheduled to have a cardiovascular implantable electronic device (CIED) such as a pacemaker, implantable cardioverter-defibrillator (ICD), or cardiac resynchronization therapy (CRT) device implanted. A PFO is a condition when there is a hole in the septum (the wall separating the right and left sides) of the heart. The purpose of this study is to determine whether closing the PFO with the GORE® Cardioform Septal Occluder in people with an endocardial device leads reduces the risk of recurrent stroke or imaging-confirmed transient ischemic attack (TIA) compared to not closing the PFO.
Hip Fracture and Patent Foramen Ovale
Hip FracturesEreth et al. showed in 1992, using transesophageal echocardiography, that the implantation of a hip prosthesis may be complicated by intracardiac embolization of various origin. A patent foramen ovale exists in approximately one fifth of the population; it facilitates the passage of embolus from the right heart to the left one and then especially to the coronary vessels and to the brain. The hypothesis supported in this research is that the prevalence of postoperative complications, especially neurological ones, is increased after surgery for hip fracture when patients have a patent foramen ovale.
Impact Of Closure Of Patent Foramen Ovale On Apnoea-Hypopnoea-Index, Nocturnal Hypoxemia And Systemic...
Obstructive Sleep ApneaThe purpose of this study in patients with obstructive sleep apnoea (OSA) and concomitant patent foramen ovale (PFO) is to assess the impact of percutaneous PFO closure on nocturnal hypoxemia and apnea/hypopnea, pulmonary and systemic artery pressure, endothelial function and arterial stiffness.
The Effect on EPCs by Successful Cardiac Occlusion Device Implantation
Foramen OvalePatent3 moreAll patients awaiting to have either a left atrial appendage closure (LAA) or patent foramen ovale (PFO) or Atrial Septal Defect (ASD) closure device as part of standard care will be identified and reviewed in cardiology clinics. These patients will be placed on waiting list to undergo the procedure. Patient-participants will be consented on the date of admission for device closure implantation. The study will recruit 20 patients divided into; 10 patients undergoing PFO/ASD closure and 10 patients undergoing LAA closure. EPC will be measured on the day of the device implantation, day 0 and prior to discharge on day 1. Patient participants are admitted overnight after the device closure implantation. Then on subsequent out patient cardiology research clinic follow appointments on days (3-4) and (7-8).
Is Blood Flow Through IPAVA and PFO Related to Breath-hold and SCUBA Diving-induced Pulmonary Hypertension?...
Patent Foramen OvaleIntrapulmonary Arteriovenous AnastamosisIn summary, the investigators propose to study elite Croatian breath-hold and SCUBA divers. The investigators will quantify breath-hold hypoxia- and SCUBA diving-induced pulmonary hypertension and right heart function to investigate the relationships between PFO and IPAVA blood flow. The investigators will use a placebo-controlled intervention (sildenafil) to reduce pulmonary arterial pressure in these subjects to examine the impact of the change in pressure (or absence of change) on the relationships determined above.
PFO Occlusion and Atrial Fibrillation
Atrial Fibrillation New OnsetEmbolic Stroke of Undetermined Source1 moreInterventional closure of patent foramen ovale (PFO) associates with reduced risk of stroke recurrence in patients with cryptogenic ischemic stroke as reported in the recent CLOSE and REDUCE trials. The long-term follow-up results of the RESPECT and DEFENSE-PFO trial confirmed these findings. PFO closure is therefore recommended in patient with cryptogenic ischemic stroke and PFO according to the current German interdisciplinary guidelines. It is likely that the number of PFO closure procedures will increase significantly in the near future. However, new onset atrial fibrillation (AF) appears to increase in patients following this procedure. In the REDUCE study, new onset atrial fibrillation was detected in 6.6% patients in the PFO closure group compared with 0.4% in the control group (medical treatment); 59% of these patients were diagnosed within the first two weeks following the procedure and 83% within 45 days, respectively. These results were consistent with the CLOSE study: AF was detected in 4.6% patients in the intervention group vs. 0.9% in the control group. Up until today, markers to identify and quantify the individual risk of AF onset are lacking. Furthermore, under-reporting and under-detection of AF occurrence after PFO closure is likely. This study is designed to to assess the prevalence and and identification of electrophysiological and echocardiographic parameters of new-onset AF.
Nickel Allergy With Septal Closure Devices
Atrial Septal DefectPatent Foramen Ovale1 moreThis study is for patients who have been diagnosed with either a Patent Foramen Ovale [PFO] or an Atrial Septal Defect [ASD]. These are a type of hole located in the wall that separates the top two (2) chambers of the heart. You have been recommended to receive an atrial septal occluder device [a device specifically designed to close PFOs and ASDs] implanted in your heart to close this hole. Because these devices are made of materials that contain nickel, this trial is being conducted to perform blood nickel tests on those patients already referred for an atrial septal occluder device such as yourself. The purpose of this study is to compare levels of nickel in the blood in patients receiving either the Amplatzer or the Helex devices.
MIST II PFO-Migraine Trial With BioSTAR® Bioabsorbable Septal Repair Implant
MigraineAura1 moreThe objective of the study is to investigate the safety and effectiveness of PFO closure with the BioSTAR Septal Repair Implant System in a population of patients that have refractory migraine (with aura) and who have failed medications.
InterSEPT: In-Tunnel SeptRx European PFO Trial
Foramen OvalePatent3 moreThe objective of this study is to determine the safety, performance, and effectiveness of the SeptRx IPO PFO Closure System in the treatment of Patent Foramen Ovale (PFO) in patients who are amenable to percutaneous closure of their PFO defects.
Paradigm I Clinical Trial: Study of the PFX Closure System in Subjects With Cryptogenic Stroke,...
Patent Foramen OvaleThe primary objective of this study is to demonstrate the safety of the PFX Closure System when utilized for patients with patent foramen ovale (PFO) suffering from cryptogenic stroke, transient ischemic attacks or paradoxical embolism.