search

Active clinical trials for "Atrial Fibrillation"

Results 1581-1590 of 3148

A Blinded Study to Evaluate Effect on Atrial Fibrillation Burden in Patients With Paroxysmal Atrial...

Paroxysmal Atrial Fibrillation

The purpose of this study is to evaluate the effect of BMS-919373 on atrial fibrillation (AF) through its effect on AF burden (AFB), or the percent of time in AF, in subjects with paroxysmal AF (pAF) when administered orally at a range of doses (2 mg once daily (QD), 5 mg QD, 12 mg QD following a 1-week period of loading doses of 3 mg QD, 8 mg QD and 20 mg QD, respectively) for a total of 4 weeks. It is hypothesized that treatment with BMS-919373 will reduce AF burden as compared to baseline relative to placebo.

Terminated16 enrollment criteria

Atrial Fibrillation and Characterization of Blood Platelet

Atrial Fibrillation

Arterial thromboembolism constitutes a major risk of atrial fibrillation (AF) requiring antithrombotic therapy. Platelets and microparticles (MPs) are important for hemostasis and thrombosis, their role during AF is not well known. The principal objective of this study is to compare morphologic, functional and proteomics characteristics of blood platelet between AF patients and healthy volunteers.

Terminated24 enrollment criteria

Evaluation of Blood Pressure Monitor With AFib Screening Feature

Atrial Fibrillation

This study aims to evaluate the safety and effectiveness of the Omron blood pressure (BP) monitor with AFib screening feature. The primary outcome is to validate if the Omron BP-monitor with AFib screening feature meets acceptance criteria in sensitivity and specificity. The acceptance criteria of the sensitivity and specificity should be statistically non-inferior to those of primary predicate device.

Completed19 enrollment criteria

Serial ECG Versus Holter to Detect Atrial Fibrillation in Elderly Ischemic Stroke Patients

Ischemic Stroke

Paroxysmal atrial fibrillation is often undetected because characteristics such as short duration, episodic, and frequently asymptomatic nature make it challenging to diagnose at the bedside, leading to suboptimal secondary prevention. It is not uncommon for paroxysmal atrial fibrillation to be undetected in a single electrocardiogram (ECG) on admission. Conventional 24-hour Holter monitoring is often used to detect paroxysmal atrial fibrillation. However, systematic review suggests Holter monitoring will identify atrial fibrillation in only an additional 4.6% of patients, no better than detection rates observed in groups lacking routine monitoring. On the other hand, for ischemic stroke patients with sinus rhythm at baseline but paroxysmal atrial fibrillation still suspected, no recommendation beyond repeated 12-lead ECGs is made in the United Kingdom guideline. Serial 12-lead ECG has been used to detect possible paroxysmal atrial fibrillation among acute ischemic stroke patients and found 15 new cases of atrial fibrillation in 133 acute ischemic stroke patients (11.3%) without atrial fibrillation at baseline. The optimal investigation strategy, including modality, duration of investigation, and patient subgroup remains undefined, not only for efficacy in the detection of atrial fibrillation, but also cost-effectiveness in healthcare systems. The objective of this project is to conduct a pragmatic multicenter randomized controlled trial for the comparison of serial 12-lead ECG once daily for 5 days and 24-hour Holter to detect paroxysmal atrial fibrillation in acute ischemic stroke patients without atrial fibrillation identified by baseline ECG or history.

Completed9 enrollment criteria

Clinical Data Validation of Novel Wireless Cortrium C3 Monitor for Continuous Electrocardiogram...

Atrial Fibrillation

The purpose of this study is to validate the quality of the ECG-signal acquired with the Cortrium C3 monitor. The intention is to evaluate whether the diagnosis of atrial fibrillation based on the ECG signal from the C3 monitor concurs with the current monitoring methods used in clinical practice.

Completed4 enrollment criteria

Left Atrial Mechanical Function Improvement After Atrial Fibrillation Catheter Ablation

Atrial Fibrillation

The objective of the study was to estimate the efficacy of telmisartan and amlodipine combination on the restoration of left atrial mechanical function after atrial fibrillation catheter ablation.

Completed10 enrollment criteria

Evaluation of the CIRCA Monitoring System in Prevention of Esophageal Lesions Following RFCA

Atrial Fibrillation

The purpose of this study is to determine if the use of Circa™ temperature monitoring system during ablation procedures will reduce the risk of esophageal lesions or damage. Esophageal lesions caused by ablation could later develop into a potentially fatal atrio-esophageal fistula, which is hole between the upper chamber of the heart and the esophagus. Although development of atrio-esophageal fistula following atrial fibrillation ablation is extremely rare, the complication is severe and potentially life-threatening. Therefore, monitoring of esophageal temperatures has been adopted to prevent the development of esophageal lesions. The Circa™ temperature monitoring system allows cardiac electrophysiologists to monitor and thereby limit temperatures as well as duration of ablation in the esophagus throughout the procedure.

Completed6 enrollment criteria

ICT-based Monitoring for Arrhythmia Detection After AF Ablation

ArrhythmiasCardiac1 more

To compare the efficacy and stability of an ICT-based centralized clinical trial monitoring system against the efficacy and stability of an existing outpatient-based electrocardiogram (ECG) and Holter monitoring system for arrhythmia detection after atrial fibrillation ablation, and to test whether such continuous monitoring can better detect arrhythmia that is undetectable by existing methods and how this may affect treatment outcomes

Completed11 enrollment criteria

Esophageal Deviation in Atrial Fibrillation Ablation

Atrial Fibrillation

Catheter ablation with pulmonary vein (PV) isolation is a commonly performed strategy employed for the treatment of atrial fibrillation (AF). However, ablation in the posterior wall of the left atrium can cause thermal injury to the esophagus. Thermal injury is very common and occurs in up to 40% of AF ablations per some studies. When significant thermal injury to the esophagus occurs, two significant complications can arise: 1) the formation of an atrio-esophageal fistula, and 2) gastrointestinal dysmotility. While the occurrence of fistula is rare, it is a very important complication since it is often fatal. Currently luminal esophageal temperature monitoring is the most commonly employed modality to prevent such injury. However, there are limitations to its use, and atrio-esophageal fistulas continue to be a major problem in AF ablation even when using esophageal temperature monitoring. Esophageal deviation using either a Transesophageal echocardiogram (TEE) or Esophagogastroduodenoscopy (EGD) probe has been described in the literature, but the effectiveness and practicality of these techniques are suboptimal, and have therefore precluded their use in routine clinical practice. Recently, esophageal deviation using off-the-shelf equipment (a soft thoracic tube and endotracheal stylet) was tested in the randomized double-blind multicenter study "Deviating the Esophagus in Atrial Fibrillation Ablation (DEVIATE-AF)". In that study the standard practice (i.e., use of luminal esophageal temperature monitoring) was compared to esophageal deviation using off-the-shelf equipment. The results were very encouraging showing that esophageal deviation allowed for significant reductions in esophageal temperature and proportion of premature ablation terminations. Importantly, esophageal deviation allowed the isolation all PVs in the treatment group, which was not the case in the control group. One major limitation in the DEVIATE-AF trial was that off-the-shelf equipment tool was challenging to use. The aim of the Esophageal Deviation in Atrial Fibrillation Ablation study is to test the feasibility and safety of moving the esophagus using a specialized esophageal deviation tool (DV8, Manual Surgical Sciences, Minneapolis, MN).

Completed16 enrollment criteria

RADAR Clinical Trial

Persistent Atrial Fibrillation

This prospective, multicenter, observational study will examine the ability of real time electrogram processing mapping to identify driver domains to target for ablation in persistent AF patients.

Completed17 enrollment criteria
1...158159160...315

Need Help? Contact our team!


We'll reach out to this number within 24 hrs