Cell-free Fetal DNA Circulating in the Maternal Plasma as a Marker for Morbidly Adherent Placenta...
Morbidly Adherent PlacentaPlacenta Accreta2 moreThe purpose of this study is to determine whether, in a high risk population (placenta praevia and previous caesarean or prenatal suspicion of morbidly adherent placenta (MAP)), the concentration of cell-free fetal DNA circulating in the maternal plasma is significantly increased in the subgroup of morbidly adherent placenta (MAP) cases , in order to determine if the dosage of cell-free fetal DNA circulating in the maternal plasma may be a useful biological tool to detect MAP, alone or in addition to the imagery findings (ultrasonography and RMI).
Magnetic Resonance Imaging (MRI ) Versus Ultrasound in Placenta Accreta Diagnosis
Placenta AccretaThird TrimesterThis study aim to assess the accuracy of magnetic resonance imaging (MRI) compared to gray-scale and colour Doppler ultrasound (US) for the prenatal diagnosis of placenta accreta.
Detection of Placenta Accreta Via Exhaled Women Breath
Placenta AccretaThird TrimesterPlacenta accreta is a relatively rare event, in which the placenta is abnormally implanted into the uterine myometrium. The most significant complication is intense bleeding, mainly during labor. The incidence of placenta accreta increased during the last years due to the increase in cesarean delivery rate, which is the main risk factor. Pre-cesarean diagnosis of placenta accreta may improve surgical outcome. Early diagnosis allows appropriate preparation of multidisciplinary team (including, among others; OB-GYN, urologists, anesthesiologists, neonatologists) and massive blood products. Pre-cesarean diagnosis is based on imaging, mainly ultra-sound. This modality has significant false positive rate which may result in extreme sources investment and even indicated pre-term labor, in vain. Volatolome is a complex of volatile markers emitted in several processes in the human body and collected from breath, skin, urine, blood, feces and more. This profile may be used to identify volatile markers for specific medical conditions. NA-NOSE is an electronic device knowing to identify differences in the Volatolome between "healthy" and "sick" subjects. The objective of this study is to identify specific volatile profile for placenta accreta which will help to distinguish between women with placenta accreta and those without.
Placenta Accreta Spectrum Protocol
Placenta AccretaAim of this project is to study diagnosis and management approaches of PAS and to assess safety and efficacy of different conservative approaches compared to planned hysterectomy. We aim at improving selection process and patient counselling for women who would like to consider alternatives to hysterectomy. To achieve these objectives, creation of an international database collected by PAS-experienced centers that represent all continents would promote conduction of large studies that provide higher level of evidence on different options of management of PAS
Management of Placenta Accreta Spectrum
Placenta PreviaPlacenta Accretaplacenta accreta spectrum is group of disorders which have a depate about the best way of management. this is a descriptive study about the best techniques to reduce morbidity and mortalities related to it.
Ultrasound in Prediction of Operative Findings in Cesarean Section Among Placenta Accreta Cases...
Placenta AccretaPlacenta PreviaA total of 60 women pregnant more than 28 weeks gestation will be recruited from obstetric outpatient clinic (faculty of medicine -Cairo University Hospital) after being diagnosed of having placenta previa or low lying placenta by grey scale ultrasound. Placenta will be reexamined by grey scale ultrasound & color Doppler. Sonographic parameters evaluated will include placental location, loss of retro-placental clear zone, irregularity and thickness of the uterine-placental interface, the smallest myometrial thickness in sagittal and transverse planes, presence of lacunar spaces and bridging vessels & the presence of abnormal vasculature. The sonographic findings will be compared with intraoperative ones. Hysterectomy specimen (if any was done) will be evaluated histo-pathologically to assess the degree of placental invasion & to confirm the accreta status. The aim of the study is to determine the efficacy of ultrasound in predicting operative findings and associated co-morbidties among cases of placenta accreta.
Comparison Between the Role of Transabdominal Ultrasound Versus Transvaginal Ultrasound in Evaluation...
Placenta AccretaObjective: To compare between the role of Transabdominal ultrasound versus Transvaginal ultrasound in evaluation of placental invasion in cases of placenta previa anterior wall with previous uterine scar applying the unified ultrasonographic descriptors suggested by the European working group on abnormally invasive placenta "EW-AIP' Also to evaluate the sensitivity and specificity of each criterion by comparing them with the final outcome of pregnancy Fifty pregnant women with persistent placenta previa (after 28 weeks' gestation) were prospectively enrolled into this study. Both transabdominal and transvaginal ultrasound were performed by two different operators who were blinded to the results of each other. the placenta was studied as regarding the exact loacalization and the unified descriptors were applied and evaluated by TAS and TVS. The ultrasound findings were analyzed with reference to the final diagnosis made during Cesarean delivery and histopathological examination
MRI for the Diagnosis of Placenta Accreta Spectrum
Placenta AccretaPlacenta Accreta Spectrum (PAS) is a disease associated with abnormal placental adhesion and invasion. In recent years, the incidence of PAS has increased significantly, which can cause massive postpartum hemorrhage, hysterectomy,and even maternal mortality. The research team of Peking university third hospital developed the ultrasound rating scale in china at first to conduct preliminary assessment of the PAS risk which can identify the severity of cases. In a basis of ultrasound, plan to explore the MRI for the the investigators diagnosis of PAS according to some specific PAS features, like the the uneven signal intensity , the myometrial discontinuity, and black band on T2 image, and finally established a MRI scoring system of PAS. MRI score system of PAS can reduce the subjective difference of the clinician's visual reading, and assist the clinician to assess the risk of sever PAS further, and conduct perioperative preparation to reduce the risk of maternal morbidity and mortality to achieve a better clinical outcome.
Maternal Serum Alpha-fetoprotein Level May Predict the Presence of Morbid Adherent Placenta
Placenta AccretaThe aim of the study is to compare between alpha-fetoproteine as a biological marker and between ultrasound and Doppler in prediction of morbid adherent placenta.
Accuracy of Three /Four-dimensional Ultrasound in Diagnosing Placenta Accreta Spectrum
Placenta Accreta SpectrumThe placenta accreta spectrum (PAS) which includes accreta, increta, and percreta represents a significant obstetric challenge. PAS complicates as many as 1 per 500 pregnancies and this risk is increased with prior cesarean deliveries. Antenatal diagnosis of PAS allows for multidisciplinary planning and delivery before the onset of labor and/or vaginal bleeding. This approach has reduced maternal morbidity rates, including less blood loss, fewer transfusion requirements and, intraoperative urologic injuries as well as improve fetal outcome. Ultrasound evaluation, with grayscale and color Doppler imaging, is the recommended first-line modality for diagnosing PAS. Grayscale ultrasound features suggestive of placenta accreta include an inability to visualize the normal retroplacental clear zone, irregularity and attenuation of the uterine-bladder interface, retroplacental myometrial thickness, presence of intraplacental lacunar spaces, and bridging vessels between the placenta and bladder wall when using color Doppler. Magnetic resonance imaging (MRI) has been used to predict the depth of placental invasion, but it is expensive and often not immediately available. Recently, a new imaging technique utilizing three-dimensional (3D)/four-dimensional (4D) volume rendering ultrasound (VRU) was proposed as a promising tool for the preoperative diagnosis of placenta previa accerta spectrum. By using "crystal vue" and "realistic vue" volume rendering mode, it could detect 11 out of 12 cases (91.6%) of PAS which was subsequently confirmed during surgery. Accordingly, The aim of this study is to examine the diagnostic performance of 3D/four-dimensional (4D) volume rendering ultrasound (VRU) for placenta previa accerta spectrum in correlation with the clinical (operative) and pathological findings.