Artificial Intelligence in the Characterization of Colorectal Polyps
Colonic PolypsCurrent guidelines recommend resection and histopathological analyses of all colorectal polyps. Real-time optical diagnosis can obviate non-neoplastic polyp resection ("diagnose-and-leave-behind") and histopathological analyses of diminutive polyps ("predict-resect-and-discard") reducing healthcare and cost burden. The investigators aimed to evaluate the diagnostic accuracy of computer-aided diagnosis using CAD EYE® (Fujifilm,Germany) in real-time optical characterization of colorectal polyps compared to endoscopic diagnosis with histopathology as the gold-standard. For this purpose, a single-centre prospective study of diminutive/small colorectal polyps is ongoing.
COmparison of White Light and Linked COlor Imaging for Detection of RIght COlon Polyps
Adenoma ColonColon Polyp1 moreComparison of the number of adenomas missed by the first exploration of the right colon by LCI (linked color imaging) or by white light during a colonoscopy, according to the order of randomization.
Computer Aided Detection of Polyps During Colonoscopy Procedures
Colo-rectal CancerPolyp of Colon1 moreThe focus of the study is to evaluate impact on Adenomas Per Colonoscopy (APC) with a Computer Aided Detection (CAD) software assisting the gastroenterologist during a colonoscopy procedure.
Artificial Intelligence Identifying Polyps in Real-world Colonoscopy
Sensitivity of the ADS in Identifying Polyps in Real-world ColonoscopyMean Number of Polyps Per Colonoscopy for Colonoscopists and Colonoscopists + ADSRecently, artificial intelligence (AI) assisted image recognition has made remarkable breakthroughs in various medical fields with the developing of deep learning and conventional neural networks (CNNs). However, all current AI assisted-diagnosis systems (ADSs) were established and validated on endoscopic images or selected videos, while its actual assisted-diagnosis performance in real-world colonoscopy is up to now unknown. Therefore, we validated the performance of an ADS in real-world colonoscopy, which is based on deep learning algorithm and CNNs, trained and tested in multicenter datasets of 20 endoscopy centers.
Collecting Recorded Videos of Colonoscopy Screening Tests
Colon PolypThe study shall mainly help to better evaluate the performance the APDS device and secondly it may help to assess the potential of the future alpha version of the device to be a useful and effective for the detection of colon Polyps.
Right Sided Colon Polyp Miss Rate: Impact Of Retroflexion In The Right Colon
Colon PolypsColon Cancer ScreeningColonoscopy is the gold standard screening test for colorectal cancer. Removal of pre-malignant colon polyps during colonoscopy reduces colorectal cancer mortality by over 50%. However, while colonoscopy is highly effective at preventing distal (left sided) colon cancers, it provides only limited protection from cancer in the proximal (right side) colon. Our goal is to determine if additional pre-cancerous colon polyps can be identified by looking at the right side of the colon in retroflexion. During retroflexion the tip of the colonoscope is turned 180 degrees; allowing the doctor to view the backs of colonic folds. If additional polyps can be identified in this manner colonoscopy will become a more efficient method of screening for colon cancer. In order to evaluate how effective right colon retroflexion is at detecting polyps in the proximal colon we plan on performing a randomized, controlled trial. Patients undergoing screening or follow up colonoscopy will be invited to participate in the study. Those patients who agree to participate will be randomized into one of two groups once the colonoscope is fully inserted. Group one will have the right side of their colon examined for polyps with the endoscope looking forward (traditional form of examination) followed by repeat examination of the right side of the colon with the colonosocpe in retroflexion (looking backwards). Polyps seen during each section of the exam will be removed and manner in which the polyps were found/ removed will be recorded. Following the two exams of the right side of the colon the colonoscopy will be completed in the usual manner. The duration of each portion of colonoscopy will be recorded. After the procedure is completed the physician performing the colonoscopy will rate difficulty of the procedure and confidence with quality of the examination. Pathology results for each polyp will be recorded once available. There will be no study related follow up after the pathology results are recorded.
High Definition Endoscopy With i-Scan for Small Colonic Polyp Evaluation: The HiScope Study
Colonic PolypsCurrent standard practice is to remove all colonic polyps found during colonoscopy as it has not been possible to distinguish between polyps with some malignant potential (adenomatous) and those with negligable malignant potential (non-adenomatous). Recent advances in endoscope imaging and technology have allowed endoscopists to distinguish between these two types of polyps by examining minute surface details. i-Scan is a new digital enhancement method that aims to enhance surface details and may enable similar accurate distinction between adenomatous and non-adenomatous polyps. Hypothesis: High definition white light endoscopy plus i-Scan improves diagnostic accuracy of in-vivo assessment of colonic polyps <10mm in size over high definition white light endoscopy alone.
Mri IN STaging REctal Polyp Planes
Rectal CancerRectal Neoplasms1 moreEarly cancers of the rectum can be removed safely through the anus without subjecting patients to major abdominal surgery in a procedure called TEMS (transanal endoscopic microsurgery). Patients undergoing TEMS can benefit from reduced mortality, impotence, hospital stay and avoiding a stoma that may be associated with pelvic surgery. Currently few of the patients eligible for TEMS are offered it for a variety of reasons that include uncertainties about the risk of leaving residual tumour and the increased risk of subsequent recurrence of cancer within the pelvis. Current UK guidelines state there is no role for imaging in assessing the malignant polyp. Conversely whilst retrospectively reviewing their MRI databank the investigators have found evidence that MRI can accurately judge the depth of these early tumours and thereby potentially identify patients for local excision. The investigators hope to prospectively test their hypothesis that an MRI scan can accurately gauge depth of tumour spread in an unselected group of benign and malignant tumours measuring between 20mm and 50mm in size. The investigators will identify eligible patients awaiting surgery / polypectomy and if they consent to this pilot study participants will undergo an MRI to assess their tumour which assesses safety at all levels of the rectal wall. The accuracy of MRI can then be established by reference to gold standard histopathology. Should MRI prove sensitive and specific then the investigators hope to change national guidelines to mandate MRI to standardise assessment and thereby increase the appropriate use of TEMS in the UK.
The Effect of Bowel Preparation Status on the Polyp Missing Rate
Colorectal PolypsColonoscopy2 moreHigh quality bowel cleaning preparation was most important prerequisites of a accurate colonoscopy, because even a small amount of residual fecal matter can obscure small polyps and increase unnecessary procedure time. Until now, several studies evaluated the impact of bowel preparation on the quality of colonoscopy using comparison of the polyp detection rate in patients with adequate bowel preparation status to that in patients with inadequate bowel preparation status during colonoscopy. However, there was no direct measurement the effect bowel preparation status on the polyp missing rate, the quality of colonoscopy, using tandem colonoscopic evaluation in prospective setting.
Collecting Recorded Videos of Colonoscopy Tests
Colon PolypThe study shall mainly help to better evaluate the performance the APDS device and secondly it may help to assess the potential of the future alpha version of the device to be a useful and effective for the detection of colon Polyps.