search

Active clinical trials for "Prosthesis Failure"

Results 1-10 of 87

DAMP1: The 1T1T Concept Versus Conventional Implant Loading Protocol

Dental Implant FailureDental Prosthesis Failure

The One tooth - One time (1T1T) innovative approach is a straightforward and cost-effective protocol to replace a missing tooth in the posterior region (Lambert and Mainjot 2017) (see Appendix). The digital impression of single unit implants right after the implant placement and the direct manufacturing of a Polymer-Infiltrated Ceramic Network (PICN) screw-retained crown allows the delivery of a final tooth in occlusion within the same day. The absence of lab procedures reduces the number of appointments, providing immediate results and high patient satisfaction. The prosthesis material choice is crucial in this procedure. Indeed, PICN high resilience, i.e. damping effect, could reduce peri-implant strain compared to ceramic materials (Magne, Silva et al. 2013) (Maminskas, Puisys et al. 2016), moreover its elastic modulus is close to tooth tissues, while other CAD-CAM composites value is too low and ceramic materials are too high. The rapid milling and manufacturing process, without any firing procedure, and the ease of adjustments (particularly to adjust proximal and occlusal contact points), make also PICNs well-adapted to chair-side systems. The material low stiffness and hardness can improve patient comfort and promote adaptation of the restorations to occlusal relationships with time. The 1T1T approach was presented as a proof of concept in a first international publication using tissue level implants from Straumann, which describes the whole protocol (Lambert and Mainjot 2017). Currently, a case series including 10 teeth is on-course, showing a 100% survival rate of implants and restorations after a 2-yr follow-up. These results are very promising but further clinical research is needed to validate such a protocol on a larger number of patients, on other implant systems as well as to compare this approach to conventional protocols.

Recruiting24 enrollment criteria

Impression & Prosthesis Quality Made From Different Polyvinylsiloxane Impression Techniques

Endodontically Treated TeethMissing Teeth5 more

This randomized controlled trial is to clinically assess and compare impression quality of polyvinylsiloxane impression material using one step (experimental) and two step (control) impression techniques and its effect on marginal fit of prosthesis and proximal contact of prosthesis.

Recruiting7 enrollment criteria

Immediate Dental Prosthesis Functionalization Protocol in People Over 70 Years of Age

Dental Prosthesis FailureFrail Elderly Syndrome

Sarcopenia and malnutrition are closely involved in frailty. To prevent them, it is essential to assess oral function. "Oral fragility" manifests with specific signs or symptoms, including occlusion loss due to tooth loss and chewing difficulty. To recover from it, restoring function by placing a dental prosthesis in the event of tooth loss is essential. In Chile, many patients referred to secondary care to perform new prosthetic treatment live in conditions of less oral functionality and enter waiting lists that can take years, impacting general functionality. Falls are a public health problem with a high economic cost, the second cause of death worldwide. One of the causes is sarcopenia, and it has been studied that the decrease in the number of teeth and the occlusal posterior support region may be risk factors for decreased gait speed, an objective measurement of fall risk. It has been studied that the decrease in the number of teeth causes a reduction in total muscle mass, walking speed and lower quality of life. General objective: To evaluate the impact on the general functionality of applying an immediate prosthetic functionalization protocol in patients with deficient removable prostheses, compared with conventional treatment, at the secondary level of the health system, in patients over 70 years of age. Methodology: randomized, double-blind clinical trial with two groups of 62 patients each: experimental and control. The intervention will consist of recovering prosthetic function in one session before conventional rehabilitation vs the control group receiving conventional rehabilitation. Measurements will include manual grip strength measurements made with a Jamar dynamometer, timed up-and-go test, before and after prosthetic treatments and quality of life related to oral health through Ohip 7sp. Descriptive statistics will be applied through the registration of frequency and contingency tables. To compare hand grip strength, Pearson's Correlation will be used; for risk of pre and post-fall, the t-test will be applied for two related samples; for quality of life before and after the intervention, Chi2 will be used; changes in grip strength, fall risk and quality of life, between the different groups according to the Eichner index, one-way ANOVA will be applied, for related samples.

Recruiting8 enrollment criteria

Performance of CAD/CAM Milled and 3D-printed Full-arch Implant-supported Provisionals Restorations...

Edentulous JawDental Prosthesis Complication1 more

This clinical trial aims to compare the performance of CAD/CAM-milled and 3D-printed full-arch implant-supported provisional restorations in patients at the Advanced Implant Prosthetics Clinic of the Complutense University of Madrid, of both sexes, over 18 years of age, edentulous upper, lower or both, whose treatment plan is at least a fixed implant-supported rehabilitation of the complete arch. The main question it aims to answer is if there are differences in the mechanical behavior and optical properties of the materials used as provisional materials in full-arch restorations on implants fabricated by CAD/CAM technology through machining or 3D printing. Participants will: - Receive milled (control material: PMMA; Multilayer PMMA block, HUGE; Shandong Huge Dental Material Corporation) or printed (test material: 3D impression resin; VarseoSmile Temp, Bego Bremer Goldschägerei Wilh. Herbst GmbH & Co. KG, Bremen) and they will be in provisional phase for 3 months doing daily life. Researchers will compare PMMA (Multilayer PMMA block, HUGE; Shandong Huge Dental Material Corporation) and the printed-resin (3D impression resin; VarseoSmile Temp, Bego Bremer Goldschägerei Wilh. Herbst GmbH & Co. KG, Bremen) to see: Mechanical behavior and the absence of complications, fracture of the structure, material jumping or wear, loosening, or detachment. Optical properties, initial color, and degradation of the materials used

Recruiting9 enrollment criteria

Epithesis Versus Prosthesis in Post-phalloplasty Transgender Patients.

TransgenderismErectile Dysfunction3 more

Transgender and gender diverse (TGD) individuals most often choose for phalloplasty as a means to create masculine external genitalia. The neophallus created in phalloplasty is usually insufficient for penetrative sexual intercourse due to the lack of erectile structures. Therefore, implantation of an internal erectile prosthesis or use of an external device or epithesis is required. Internal prostheses are the main method for attaining penile rigidity after phalloplasty, but they carry a high risk of complications. Previous research has shown that up to 22% of prostheses for cisgender men were explanted due to various reasons, including infection, erosion, and malfunction within 20 months. The lack of reliable and durable erectile devices leads to a large proportion of patients either choosing phalloplasty but never going for the placement of an erectile prosthesis or completely abandoning the idea of GGAS under the form of phalloplasty. Secondarily, TGD individuals may be concerned about complication rates and likely need for additional surgeries associated with penile implant surgery. Therefore, alternative options for transgender and gender non-conforming patients after phalloplasty are needed. These alternatives may be surgical or non-surgical. External penile epitheses or penile splints were originally designed for cisgender men with erectile dysfunction but have been used experimentally by post-phalloplasty transgender men. While there is no data on the usability and durability of penile epitheses in a TGD population, they may be a viable alternative to an internal penile prosthesis after phalloplasty. Penile lifters or splints, marketed as ElatorTM or ErektorTM, are commercially available and consist of two rigid rings connected by rigid metal rods. The biggest of two rings is placed around the base of the phallus, and the second ring is placed behind the coronal ridge. By connecting the rods to the ring at the base of the penis, tension and rigidity between the two rings is created, allowing the user to penetrate their partner and remove the device after intercourse. The current study aims to extend the knowledge on these external devices by comparing them to the implantation of an internal penile prosthesis in post-phalloplasty transgender patients.

Recruiting24 enrollment criteria

RCT: Titanium vs FCZ vs Zirconia Framework

Dental Prosthesis Failure

In recent years, zirconia-based implant-supported bridge designs have begun to be used more and more as an alternative to metal ceramic bridges. Another new material that has been introduced in the clinic is the high translucent monolithic zirconia, which has only been investigated a few follow-up studies with short follow up duration. The aim being to evaluate the clinical outcome of implant-anchored posterior bridges, made from high-translucent monolithic zirconia, zirconia ceramic with porcelain and metal ceramics. The hypothesis is that high-translucent monolithic zirconia has lower rate of complications since surface porcelain veneering is not required. A total of 60 research subjects will be included in the study. Patients in need of a permanent implant-supported bridge, located posterior of the canine in the upper or lower jaw will be asked for participation. Each subject will be treated according to standard treatment protocols with implants from Nobel Biocare, the Branemark implant system and then be randomly assigned to obtain one of the following three type of bridges. 20 research subjects will be included in each of the three study arms. The prosthetic treatment will be carried out according to standard clinic protocol. All research subjects will be evaluated after 1, 3, 5 years. X-rays and photos will be taken at the installation of the bridges and after 1 and 5 years of follow-up or more frequent, depending on individual indication of the patient and the associated standard clinical care protocol. Personal data, implant survival, marginal bone loss and biological and technical complications related to the implants will be recorded. Survival of the bridge, technical and biological complication related to the bridge will also be recorded

Recruiting4 enrollment criteria

Cup Revisions Through Anterior or Posterolateral Approach: an RCT

LooseningProsthesis

With increasing numbers of total hip arthroplasties performed each year, the incidence of problems related to loosening and wear of total hip arthroplasties is expected to also increase. While the anterior approach for primary total hip arthroplasty has demonstrated to result in a faster short-term recovery than the traditional lateral and posterior approach, this effect has not yet been investigated in revision surgery. Accelerating functional outcome may increase patient satisfaction and reduce healthcare costs. The primary objective is to assess whether isolated cup revision surgery through the anterior approach results in increased functional status and higher patient satisfaction than through the posterolateral approach. This is a prospective Randomized Controlled Trial (RCT) in which 68 patients will be included (34 per group). Patients will be evaluated preoperatively and 6 weeks, 3 months and 1 year postoperatively. The main endpoints are functional recovery as measured with the 30-sec Chair Stand Test (30s-CST), 40m Fast Paced Walking Test (40m FPWT) and the Stair Climb Test (SCT). Secondary endpoints are Modified Borg scale outcomes after the functional tests, Numeric Rating Scale (NRS) for pain (rest/movement), Oxford Hip Score (OHS), HOOS-PS, EQ-5D-5L, satisfaction, cup inclination and complications at 30 days and 90 days postoperatively.

Enrolling by invitation8 enrollment criteria

Partial Implant-supported Rehabilitation Using PEEK

Prosthesis Survival

The goal of this observational study is to evaluate the outcome of a Poly-ether-ether-ketone - used in partial implant-supported rehabilitations after one year of follow-up. The main question it aims to answer is: - What is the survival outcome of partial implant-supported prosthesis using Poly-ether-ether-ketone? The participants already rehabilitated with dental implants will receive a definitive 3 unit prosthesis incorporating Poly-ether-ehter-ketone.

Enrolling by invitation7 enrollment criteria

Single Tooth Implant-supported Fixed Prosthetic Rehabilitation Using PEEK.

Prosthesis Survival

The goal of this study is to evaluate the outcome of a Poly-ether-ether-ketone - used in single teeth implant-supported rehabilitations after one year of follow-up. The main question it aims to answer is: - What is the survival outcome of single teeth implant-supported prosthesis using Poly-ether-ether-ketone? The participants already rehabilitated with a single tooth dental implant will receive a definitive prosthesis incorporating Poly-ether-ehter-ketone.

Enrolling by invitation7 enrollment criteria

Accuracy of 3-dimensional Printed Implant Cast Versus Conventional Stone Cast for Edentulous Mandibular...

Prosthesis Durability

This study will be conducted to compare between accuracy of 3D printed implant cast produced from digital impression and conventional stone cast produced from conventional splinted open tray impression for edentulous mandibular arch with four implants.

Enrolling by invitation11 enrollment criteria
12...9

Need Help? Contact our team!


We'll reach out to this number within 24 hrs