Sedation in the Intensive Care Unit
Critical IllnessRespiratory FailureHigh-risk critically ill patients often require mechanical ventilation either to primarily support the respiratory function or when the ventilation is insufficient to maintain adequate gas exchanges as a result of other organ impairment. In order to tolerate this aggressive mechanical support, enhance patient synchrony with the ventilator, and relieve pain and anxiety, analgesia and sedation are provided. It is suggested that an inappropriate use of sedation and analgesia may prolong the duration of mechanical ventilation and increase the risk of specific adverse outcomes such as ventilator associated pneumonia. Despite the widespread use of sedation, little information is available concerning the effect of varying the level of sedation on patients' subsequent mental health. We designed a randomized controlled trial to investigate the efficacy of sedation with the goal of maintaining the patient cooperative and interactive compared to the administration of sedation with the goal of maintaining the patient sedated. The first goal will be achieved by a discontinuous injection of a sedative, while the second goal will be achieved by a continuous infusion of the same sedative. In both groups pain relief will be provided in the same fashion with equal endpoints on a pain scoring scale. Our primary aim is to investigate whether differences in the occurrence of post-traumatic stress disorders (PTSD), anxiety, and depression are related to the choice of sedation-analgesia strategies. Secondary endpoints include the length of ICU stay, as indicated by the time to discharge from the ICU, the time to separation from mechanical ventilation, the rates of pulmonary and extra-pulmonary complications, and hospital length of stay. These endpoints will be compared between the two groups.
Observational Study of Blood Pressure Measurements and Continuous Dialysis
Kidney FailureRespiratory Failure2 moreDialysis is used to control the fluid balance and metabolic state of patients with kidney disease. Control of the metabolic state, via electrolytes, can be monitored using labs that are routinely drawn from patients undergoing continuous hemodialysis. Control of fluid removal is much more difficult. This study aims to determine whether changes in the blood pressure associated with breathing correlate with or predict intolerance to fluid responsiveness with continuous dialysis. We hypothesize that a measurement of changes in blood pressure with breathing called arterial pulse pressure variation may be able to predict the ability to remove fluid during continuous renal replacement therapy.
Positive and Quantitative Diagnosis of Pleural Effusions by Thoracic Ultrasonography in Patients...
Pleural EffusionUltrasonography3 moreAcute respiratory failure (ARF) is a frequent reason for consulting in the Emergency Department (ED) and one of the major clinical problems prompting admission in intensive care unit. In the ED, evaluation of an ARF is mainly based on clinical examination and frontal chest x-ray performed to the patient bedside. This practice has a limited diagnostic capacity due to a lack of specificity of clinical and radiological semiology, especially in the polypathological patient. Thoracic ultrasonography provides morphological information regrouped as a syndrome (interstitial syndrome, alveolar condensation, pneumothorax) and allows the identification of pleural effusions (PE). The PE diagnosis is easy, quick, and relies on two-dimensional ultrasound imaging. Compared to CT scan, which remains the reference examination although ill-suited in the context of emergency, thoracic ultrasonography has a sensitivity and specificity greater than 90% for pleural liquid (PL) diagnosis. In addition, thoracic ultrasonography is used to assess the volume of PL, determine its nature and guide the pleural puncture with higher performance than chest x-ray. The semi-quantitative evaluation of PEs has been validated in patients with mechanical ventilation hospitalized in intensive care unit. On the other hand, few data on the prevalence and quantification of PL for hospitalized patients in ED for an ARF are currently available. Thus, the objective of this study is to evaluate the prevalence and severity of the PL identified by thoracic ultrasonography in patients admitted to the ED for an ARF by emergency physicians with ultrasound skills recommended by the French Society of Emergency Medicine.
ARDS Esophageal Balloon Pressure Changes With Positioning Study
ARDSRespiratory FailureThe use of esophageal balloon catheters, which use esophageal pressure as a surrogate measurement for transpleural pressure, shows promise in improving outcomes of patients with severe acute respiratory distress syndrome (ARDS) requiring mechanical ventilator. The investigators hope to measure changes in in transpleural pressures in patients undergoing treatment with mechanical ventilation while switching from the supine, upright (head of bed >30 degrees), and prone positions. The goal will be to measure the changes in chest wall and lung compliance in mechanically ventilated patients with changes in position.
Muscle Atrophy in Patients With Severe Sepsis
Severe SepsisRespiratory FailureThis study is being done to help determine whether patients with severe sepsis (overwhelming inflammation in the body as a result of an infection) lose muscle and become weak more rapidly than patients with other severe illnesses. Weakness and muscle loss that develops after a severe illness is a serious problem. Patients who develop weakness and have a decrease in muscle size often have to stay in the hospital longer and have a higher chance of dying. At the current time, it is not clear whether certain severe illnesses are more likely to cause weakness and muscle loss. This study will be done to measure the changes in muscle size and strength as a result of each patient's illness
Incidence of Respiratory Depression in Cesarean Section
Respiratory DepressionPostoperative PainThis study is designed to determine the incidence and severity of respiratory depression in elective cesarean section patients who have received a spinal or epidural narcotic called duramorph for management of postoperative pain. A monitoring device called a capnograph as well as a device called a pulse oximeter is placed on the patient once in the recovery room after delivery. The capnograph monitors the carbon dioxide level that the patient breathes out as well as their respiratory rate. The pulse oximeter is a device that is taped on the patient's finger and measures their oxygen saturation level. The monitoring is maintained for 18-24 hours after surgery.
Respiratory Depression in Women With BMI≥30 Underwent Spinal Anesthesia With Intrathecal Morphine...
Respiratory DepressionThe study will examine whether there is a difference in the frequencies of respiratory depression among obese women receiving spinal anesthesia combined with opioids compared to women with normal BMI. If such a risk exists further investigation will be required to establish the proper criteria for the administration of morphine with spinal anesthesia to obese women.
Education and Training Competences in Thoracic Ultrasound
Respiratory FailureDyspnea3 moreThe use of thoracic ultrasound has expanded widely within the las couple of years, and several studies have proved a high diagnostic accuracy for many of the most common causes of respiratory failure and dyspnoea. The ultrasound scan is a bed-side, and dynamic examination, which demands sufficient theoretical and practical knowledge and competence by the operator, but so far, no studies have explored the effect of simulation-based training for gaining adequate competence compared to traditional hands-on training on healthy figurants. The aim of this study is to examine whether TUS training on a simulator is superior to training on healthy figurants. Secondly, to examine whether the choice of hands-on training has an effect on the number of examinations performed by the trainees from baseline to 4 months follow-up.
Impact of the Inspiratory Cortical Control on the Outcome of the Ventilatory Weaning Test in Patients...
Respiration DisorderRespiratory Failure3 moreIn case of respiratory distress, patients are intubated to be connected to an artificial respirator to ensure gas exchanges. Before any ventilatory weaning, a breathing test in spontaneous ventilation under artificial nose is practiced. The patient keeps the endotracheal tube but is no longer assisted by the ventilator. Mortality is markedly increased with the prolongation of the weaning period. Despite the presence of all weaning criteria and the success of a breathing test in spontaneous ventilation under artificial nose, failure of extubation occurs in 20% of patients. Experimental application of an additional inspiratory load in awake healthy subjects causes a compensatory increase in respiratory work to maintain effective ventilation, and the subject does not develop hypoventilation. This respiratory drive to breathe has been demonstrated by quantified electroencephalography in inspiratory load tests in the form of pre-inspiratory negative deflections of low amplitude similar to the potential described during the preparation of the voluntary movement of a limb. These inspiratory pre-motor potentials begin about 2.5 seconds before the start of a movement in the additional motor area. Does the simple and noninvasive analysis of inspiratory cortical control during the spontaneous ventilation breath test under artificial nose predict the outcome of this test as well as weaning at 7 days?
Effect on paO2 of Adding an Aerosol Mask Above the Nasal Canulas
Hypoxemic Respiratory FailureEmergencies1 moreThis study will compare the impact of a classical aerosol mask above low-flow nasal cannula on the arterial oxygen tension in patients with COVID-19.