search

Active clinical trials for "Miosis"

Results 1-8 of 8

Pupillary Unrest as an Indicator of Central Opioid Effect in Subjects 40-60 Years of Age

Opioid ToxicityPupillary Miosis1 more

This study will establish the relationship between magnitude of opioid exposure and a pupillary measure referred to as PUAL (pupillary unrest in ambient light), in subjects aged 40-60. Previous investigation demonstrated that loss of PUAL was a sensitive, discriminative indicator of opioid toxicity and respiratory depression among subjects aged 20-40 years old. Population data indicate that pupil size and PUAL decline slightly with age. The investigators will explore whether PUAL proves to be a sensitive indicator of opioid exposure and respiratory depression in this older group.

Recruiting12 enrollment criteria

Use of APX 100 Device for Small-pupil Cataract Surgery and Intraoperative Floppy-iris Syndrome

Miosis DisorderIntraoperative Floppy Iris Syndrome

The purpose of the study is to gather clinical data and safety information on the use of APX 100 device for small-pupil cataract surgery and the management of intraoperative floppy iris syndrome (IFIS) during cataract surgery. The APX 100, a FDA-approved device (510K exempt), is a disposable stainless steal sterile device for mechanical expansion of pupillary diameter during intraocular surgery. The APX 100 is inserted to the anterior chamber of the eye through standard clear corneal incisions. The device is then located on the pupil's border between the iris and the anterior lens capsule and the pupil's diameter is expanded. The APX 100 will be used in standard phacoemulsification cataract extraction surgery when small pupil diameter (<4.5 mm) is recognized preoperatively or develops intraoperatively due to IFIS.

Completed6 enrollment criteria

Efficacy of the Canabrava/s Pupil Expansion Device in Cataract Surgery With Small Pupils: The First...

Small PupilCataract

To evaluate the intraoperative stability, safety and overall efficacy of the Canabrava Ring (AJL - SPAIN) when used to expand pupils with less diameter than 5 mm and pupils with sphincter synechiae.

Completed2 enrollment criteria

Evaluation of an Iris Dilatation Ring in Cataract Surgery (ADICC-ID)

Small Pupil

During cataract surgery, it is necessary to dilate the iris in order to remove the crystalline lens and position the implant. The diameter of the optical implant being 6 mm, in case of capsulorhexis crystalline access 5.5 mm, the expansion should be at least 6 mm. At pre-operative consultation, the iris is always dilated by instillation of eye drops and measured at the slitlamp. For patients with an inadequate dilation, the intervention requires the use of a mechanical dilatation device. This study aims to assess the value of an alternative dilatation ring to Malyugin ring, which can be inserted and removed through an incision of less than 2 mm in diameter, due to its size smaller than that of the Malyugin ring. Our hypothesis is that this Bhattacharjee ring ensures sufficient and stable iris dilation during surgery, enabling implant placement in good conditions.

Completed9 enrollment criteria

Efficacy of an Ocular Bandage Contact Lens for the Treatment of Dry Eye After Complicated and Combined...

CataractLens Subluxation3 more

To study the efficacy of an ocular bandage contact lens for the treatment of dry eye after complicated and combined cataract surgery

Unknown status7 enrollment criteria

Methods to Manage Intra-operative Floppy-iris Syndrome and Poor Pupil Dilation in Cataract Surgery...

Management of Intraoperative Floppy-iris Syndrome and Small Pupils With Different Mechanical Devices

Cataract surgery is one of the most frequently performed surgeries worldwide and complications are rare. However, there are factors that increase the risk of complications, such as poor pupil dilation and intra-operative floppy iris syndrome (IFIS). Reasons for a small pupil size are pseudoexfoliation syndrome (PXF) syndrome, uveitis or synechia and the use of pilocarpin drops. IFIS is a syndrome usually caused by systemic alpha1-blockers (foremost tamsulosin) used to treat benign prostatic hyperplasia.1,2 As described by Chang and Campbell3 IFIS is characterized by billowing of a flaccid iris stroma, a propensity for iris prolapse towards the phacoemulsification tip as well as towards the incisions and progressive intra-operative pupil constriction. Stopping tamsulosin pre-operatively did not show to effectively prevent IFIS.4,5 However, it is of high importance to identify patients prior to surgery, who are treated with alpha1-blockers, or patients with a small pupil size and poor pharmacological pupil dilation. Some methods, such as intracameral injection of phenylephrine is only sufficient in a few cases 6, and a disadvantage is the risk of a hypertensive episode.7 Another pharmacological method is the use of atropine drops pre-operatively, but this method did not show to sufficiently reduce IFIS.4 Different methods were shown to reduce intra-operative problems due to IFIS/small pupil size: The use of highly cohesive ophthalmic viscosurgical devices (OVD), also called viscoadaptives, such as sodium hyaluronate (e.g. AMO Healon5 or Croma Eyefill H.D.) help to viscodilate the pupil and by resting on the iris during the entire phacoemulsification procedure reduce the risk of iris prolapsing towards the incisions. This method is more dependent on a central phacoemulsification technique and low fluidic parameters to allow the OVD to stay on the iris during the entire procedure.8 In case of a small pupil, pupil stretching with 2 instruments can be used additively. Another option to stabilize the pupil size is the use of mechanical pupil expansion devices, such as Iris retractors - these devices are routinely used to dilate the pupil intra-operatively. Typically, 4 or 5 iris retractors, also called iris hooks, are inserted through 4-5 incisions. Usually, the IFIS pupil is very elastic and the risk of overstretching is small.8 Pupil expansion rings, such as the Malyugin ring. This ring is placed on the pupil margin with an injector through the main incision. It eliminates the need of additional incisions and saves time.9 Rationale To compare different methods to manage IFIS and poor pupil dilation in cataract surgery: a pupil expansion ring (Malyugin Ring), iris retractors (iris hooks) and a viscoadaptive OVD.

Unknown status9 enrollment criteria

Clinical Factors Associated Floppy Iris

Pupil ConstrictionIris Floppiness1 more

This study is planned to investigate the incidence of intraoperative floppy iris and its relationship with pseudoexfoliation, diabetes, hypertension as well as systemic alpha-1 adrenergic blocker use.

Completed3 enrollment criteria

Nepafenac Versus Ketorolac Eye Drops in Prevention of Intraoperative Miosis During Cataract Surgery...

CataractMiosis

This study aim at determining the efficacy of Nepafenac and Ketorolac in obtaining adequate intraoperative mydriasis and preventing miosis during cataract surgery. It also compare the efficacy of both Nepafenac versus Ketorolac, and determine the more effective agent in preventing miosis during cataract surgery. The investigators try to determine if the effect of preoperative NSAIDs agents use would show a financial benefit, or this manoeuvre would add a financial load on the patients who are candidate for cataract surgery.

Unknown status6 enrollment criteria
1

Need Help? Contact our team!


We'll reach out to this number within 24 hrs