Registry of Malignant Arrhythmias and Sudden Cardiac Death - Influence of Diagnostics and Interventions...
Ventricular TachycardiaVentricular Fibrillation6 moreThe "Registry of Malignant Arrhythmias and Sudden Cardiac Death - Influence of Diagnostics and Interventions (RACE-IT)" represents a mono-centric registry of patients being hospitalized suffering from malignant arrythmias (ventricular tachycardia or fibrillation) and sudden cardiac death (SCD). Detailed findings of patients' clinical outcome regarding mortality and co-morbidities related to the presence of invasive diagnostics or therapies including coronary angiography, percutaneous coronary intervention (PCI), electrophysiological testing (EP), catheter ablation and implanted cardiac devices (e.g. implantable cardioverter-defibrillators) will be documented. Patients will be included when being hospitalized from the year 2004 until today.
Pregnancy Related Inappropriate Sinus Tachycardia
Inappropriate Sinus TachycardiaPregnancy RelatedA feasibility study into the exploration of possible mechanisms underlying inappropriate sinus tachycardia (IST) syndrome in pregnancy.
Austrian Wearable Cardioverter Defibrillator Registry
Heart FailureVentricular Dysfunction4 moreBackground: The wearable cardioverter defibrillator (WCD) is an established treatment option for patients at high risk for ventricular tachycardia / ventricular fibrillation (VT/VF), either in whom this risk may only be temporarily present, or in patients at high risk for sudden cardiac death (SCD) or after VT/VF in whom an implantable cardioverter defibrillator (ICD is currently not possible for other reasons (infection, recent MI <40days, recent PCI/CABG < 3months etc.). Methods: Comprehensive registry including all patients in Austria who received a WCD in 2010-2016.
The Western Galilee Hospital in Nahariya Home Monitoring Registry
TachycardiaThe purpose of this study is to study workload assessment of home monitoring based follow up for ICD or CRTD implanted patient.
Electromechanical Profiling of the Long-QT Syndrome (LQTS)
Long QT SyndromeSudden Cardiac Death1 moreHigh-resolution, non-invasive electromechanical mapping in genotyped long-QT syndrome patients and healthy controls at baseline and during smart provocation.
Atrial Tachycardia as a Predictor of Atrial Fibrillation, Stroke and Mortality in Cryptogenic Stroke...
Cryptogenic StrokeAtrial Fibrillation1 moreThere is few information about the association between supraventricular arrhythmia different from atrial fibrillation (AF) or atrial Flutter and the risk of stroke. In this study the investigators hypothesized that the presence of atrial tachycardia would lead to atrial fibrillation and recurrent stroke in patients hospitalized for cryptogenic stroke. The investigators study the association of atrial tachycardia (AT), defined as four or more consecutive premature atrial beats, and AF, recurrent stroke and cardiovascular mortality in 192 consecutive patients hospitalized because of cryptogenic stroke. The follow-up was 12 months for all population
Modification of Rhythmic Risk Assessment by Ventricular Tachycardia Ablation
Ventricular TachycardiaSudden cardiac death is a frequent cause of cardiovascular mortality. Numerous rhythmic risk assessment criterion have been described targeting the substratum, the cardiac nervous tone or the trigger of arrhythmias. Development of ventricular tachycardia ablation in the past few years show interesting results preventing the recurrence of ventricular arrhythmias.
A Feasibility Study on Prediction of an ICD Shock by ICD-derived Data
Sudden Cardiac ArrestVentricular Tachycardia1 moreThe primary hypothesis is that an ICD shock may be predicted days in advance by a combined score derived from different data obtainable from the ICD
Post-Extrasystolic Potentiation as a Predictor of Ventricular Arrhythmias
Post-extrasystolic Potentiation (PESP)Ventricular TachycardiaBackground: Patients at increased risk for sudden cardiac death (SCD) may receive an implantable cardioverter defibrillator (ICD). The primary criterion for a primary prevention ICD implantation is a left ventricular ejection fraction (LVEF) below 35%, but refinement of ICD criteria is important since only a small proportion of ICD patients receives appropriate device therapy (ATP or a shock) during follow-up. Post-extrasystolic potentiation (PESP) may be a new risk marker for SCD. PESP is defined as a temporary increase in contractility that follows an extrasystolic beat (ESB) and is associated with myocardial calcium handling. In heart failure, changes in calcium homeostasis may lead to afterdepolarisations and thus predispose for SCD. PESP can be measured indirectly and non-invasively as post-extrasystolic blood pressure potentiation (PESP-BP). Abnormal PESP-BP was previously found to be an independent predictor of increased mortality in post-myocardial infarction patients with a reduced LVEF. However, it is unknown if this increased mortality in heart failure patients with abnormal PESP-BP is caused by an increased risk of SCD. Hypothesis: The investigators hypothesize that PESP-BP might be a new predictor of the occurrence of SCD, and can be used to enhance patient selection for primary prevention ICD therapy. Design: During scheduled device replacement ESB with various extrasystolic and post-extrasystolic coupling intervals will be evoked by electrical stimulation via the right atrial and ventricular device leads of the patient. Throughout the stimulation study blood pressure will be measured non-invasively a continuous electrocardiogram will be recorded. Either before or after the procedure, patients will undergo a 30-minutes assessment of spontaneous ESB, again with blood pressure and ECG recordings. Study population: 30 patients who are scheduled for device replacement or reposition, are eligible for this study; (1) 10 ICD patients who previously received appropriate device therapy (ADT); (2) 10 ICD patients who are free from ADT and (3) 10 dual-chamber pacemaker patients (control group). Outcomes: (1) Evoked PESP-BP (i.e. blood pressure differences between baseline, ESB and post-ESB); (2) Spontaneous PESP-BP (i.e. blood pressure differences between baseline, ESB and post-ESB); (3) Timing parameters (in ms): the basic cycle length interval; Extra-systolic interval (ESI); Post-extrasystolic interval (PESI).
R Wave Sensing After VT Ablation
TachycardiaVentricular3 moreSustained, monomorphic ventricular tachycardia (VT) is most commonly encountered in patients with structural heart disease, usually with ischemic aetiology. It has been proven that repeated episodes of sustained VT contribute to the mortality of patients with structural heart disease. These patients are usually implanted with implantable cardioverter defibrillator without (ICD) or with cardiac resynchronisation therapy (CRT-D). According to the current guidelines 3D mapping with radiofrequency (RF) ablation of the tachycardia substrate is an established therapeutic option. As part of the clinical follow-up of patients implanted with cardiac implantable electronic devices (CIED), CIED function parameters are monitored every 6 months, which is always done before and after any procedure involving RF ablation. Furthermore, a transient drop of R wave sensing has been demonstrated after the atrioventricular (AV) node ablation in patients with single-chamber pacemakers and fast atrial fibrillation. The aim of this study is to assess the change in R wave sensing after the RF ablation of VT substrate. This study will be performed as a clinical, prospective, multi-centre, observational cohort study with a structured follow-up period of 12 months. All consecutive patients with sustained VT implanted with ICD or CRT-D undergoing RF ablation procedure of myocardial substrate, who are able to understand and sign informed consent, will be enrolled. Primary objective is a R wave sensing drop > 30% after VT substrate ablation procedure. Recruiting should not exceed 12 months with the minimal follow-up period of 12 months (24 months in total). Standardized statistical methods and test will be done using SPSS Software Version 22.0 or newer. This unique study offers the possibility to show the impact of RF ablation on short-term and long-term R wave sensing change assessed by ICD or CRT-D's ventricle electrode in patients with sustained VT and structural heart disease undergoing ablation procedure. This observational data is needed to further refine the treatment of these patients and to prevent possible ICD/CRT-D dysfunction which could endanger this patient population.