search

Active clinical trials for "Tricuspid Valve Insufficiency"

Results 131-140 of 144

Effectiveness and Durability Long-term Results of Tricuspid Annuloplasty With 3D Shaped Rings.

Functional Tricuspid Regurgitation

Interest in tricuspid valve disease has grown exponentially over the past few years, in response to increased interest in the poor prognosis of patients with functional tricuspid regurgitation (TR). Tricuspid valve repair (TVR) using a prosthetic ring represents the first option in many centers worldwide, due to the low incidence of residual and recurrent TR and improved survival compared to suture techniques. The goal of ring annuloplasty is to restore the normal geometry of the annulus, thereby improving the coaptation of the leaflets and preventing further dilatation of the annulus. Recently, the three-dimensional geometry of the tricuspid valve has been shown and analyzed by means of data obtained from echocardiography, CT scan and magnetic resonance imaging. Normal tricuspid annulus is characterized by a more prominent part in the anteroseptal commissure area near the aortic valve and right ventricular outflow tract and a deeper part in the posteroseptal commissure area near the coronary sinus ostium . Based on these characteristics, new three-dimensional rings have been developed for tricuspid annuloplasty, such as the MC3 (Edwards Lifescience, Irvine, CA) and the Contour 3D (Medtronic, Minneapolis, MN). There are few studies concerning the short-term results of tricuspid rings implantation and almost none on the long-term, therefore this study aims to analyze the long-term results of TVR by implantation of the two new prosthetic ring models mentioned above. The aim of this study is the long-term analysis of the results of tricuspid annuloplasty with three-dimensional rings in patients with functional IT.

Completed5 enrollment criteria

Long-term Outcomes of Isolated Tricuspid Valve Surgery According to Preoperative Clinical and Functional...

Tricuspid Regurgitation

Tricuspid regurgitation (TR) was identified as an independent prognostic factor associated with excess mortality and morbidity, independent of left ventricular (LV) function and pulmonary hypertension. Isolated tricuspid surgery has been performed for a long time in a few selected cases, however in recent years several studies have underlined how the poor outcomes described for isolated tricuspid valve surgery seem to be related to the baseline characteristics of the patients and to late referral for surgical treatment rather than the intervention itself. To facilitate patient screening, a new clinical and functional TR staging system has recently been proposed. This classification, which evaluates the progression of morphological variations of the tricuspid valve and right ventricle (RV) in association with the onset of symptoms, identifies several parameters and factors that can be useful for a better stratification of surgical risk. Rather than simply assessing the degree of TR, this new staging mechanism also focuses on symptoms, RV remodeling and function, medical therapy, and right heart failure hospitalizations. Investigators previously focused on the short-term (mainly hospital) outcomes of patients undergoing isolated surgery for severe TR, who were classified at baseline according to this clinical and functional staging system. Results showed that a more comprehensive classification reflects the population and hospital outcomes of surgically treated patients with isolated TR. The purpose of this study is to ultimately evaluate long-term outcomes of this patients population and estimate the impact of baseline staging on long-term outcomes.

Completed5 enrollment criteria

Lymphatic Function in Patients With Secondary Tricuspid Valve Regurgitation

Lymphatic InsufficiencyHeart Failure1 more

The study will examine the lymphatic functional and morphological status in patients with moderate tricuspid valve regurgitation compared to healthy age and gender-matched controls. The study will use t2 weighted MRI, Near-infrared fluorescence imaging, and plethysmography to examine the above-mentioned question.

Completed22 enrollment criteria

Outcome of MC3 Ring Annuloplasty for Functional Tricuspid Regurgitation

Functional Tricuspid Regurgitation

This study includes 105 patients who underwent repair for ≥ moderate tricuspid regurgitation (TR) during mitral valve replacement for rheumatic valve disease. Between January 2016 and December 2018, a group of 23 patients underwent ring annuloplasty with Edward MC3 rings were compared to another group of 82 patients underwent standard suture (DeVega) repair. The primary outcome was residual TR (≥ moderate TR).

Completed13 enrollment criteria

Automated Phonocardiography Analysis in Adults

Aortic InsufficiencyAortic Stenosis7 more

Background: Computer aided auscultation in the differentiation of pathologic (AHA class I) from no- or innocent murmurs (AHA class III) via artificial intelligence algorithms could be a useful tool to assist healthcare providers in identifying pathological heart murmurs and may avoid unnecessary referrals to medical specialists. Objective: Assess the quality of the artificial intelligence (AI) algorithm that autonomously detects and classifies heart murmurs as either pathologic (AHA class I) or as no- or innocent (AHA class III). Hypothesis: The algorithm used in this study is able to analyze and identify pathologic heart murmurs (AHA class I) in an adult population with valve defects with a similar sensitivity compared to medical specialist. Methods: Each patient is auscultated and diagnosed independently by a medical specialist by means of standard auscultation. Auscultation findings are verified via gold-standard echocardiogram diagnosis. For each patient, a phonocardiogram (PCG) - a digital recording of the heart sounds - is acquired. The recordings are later analyzed using the AI algorithm. The algorithm results are compared to the findings of the medical professionals as well as to the echocardiogram findings.

Completed1 enrollment criteria

Hemodynamic Implications of Transcatheter Tricuspid Valve Repair in HFpEF Patients

Congestive Heart FailureTricuspid Regurgitation

The aim of the study is to investigate the pathophysiological implications of transcatheter tricuspid valve edge-to-edge repair in patient with heart failure and preserved ejection fraction and severe tricuspid regurgitation. Changes in right- and left-ventricular function as well as the interventricular dependence will be analysed on a multimodal basis including pressure-volume loop analysis and cardiac magnetic resonance imaging.

Unknown status9 enrollment criteria

Cardiac Remodeling and Prognosis in Secondar Tricuspid Regurgitation

RemodelingCardiac1 more

The aim of this study is to improve the definition of the two main types of secondary tricuspid regurgitation.

Completed11 enrollment criteria

Acute Normovolemic Hemodilution on Serum-creatinine Concentration in Cardiac Surgery

Mitral RegurgitationMitral Stenosis1 more

Serum-creatinine level (s-Cr) is an important factor for predicting perioperative patient's outcome regarding acute kidney injury. Although cardiopulmonary bypass (CPB), an essential procedure for cardiac surgery, dilutes patient's blood components, possible impact of applying acute normovolemic hemodilution (ANH) and CPB on s-Cr has not been well investigated. In patients undergoing cardiac surgery employing moderate hypothermic CPB (age 20-71 years, n=32), ANH will be randomly applied to 15 patients (Group-ANH) but not in 17 patients (Group-C) before initiating CPB. For ANH procedure consisting of 5 ml/kg of blood salvage and administering 5 ml/kg of balanced hydroxyethyl starch (HES) 130/0.4 for 15 min will be started at 30 min after anesthesia induction and before CPB application for surgery. In both groups, moderate hypothermic CPB will be initiated by using 1600-1800 ml of bloodless priming solution. The changes of hematocrit (Hct), Na+, K+, HCO3-, Ca2+, osmolarity, s-Cr will be determined before ANH (T1), after the first ANH of 2.5 ml/kg (T2), and after the second ANH of 2.5 ml/kg (T3), 30 sec and 60 sec after the initiation of CPB (T4, T5), immediately and 1 hour after the weaning from CPB (T6, T7) and at the end of surgery (T8). S-Cr will be determined by using a point-of-care test device (StatSensor™ Creatinine, Nova Biomedical, USA).

Completed7 enrollment criteria

Prevention of Pacemaker Lead Induced Tricuspid regurgitAtion by Transesophageal eCho guidEd Implantation...

Tricuspid Valve InsufficiencyPacemaker Complication2 more

Registry for patients undergoing pacemaker/ICD implantation including a transtricuspid lead with and without intraprocedural transesophageal echocardiography to evaluate risk factors for lead induced tricuspid regurgitation.

Completed3 enrollment criteria

Cardiac Output Pulmonary Arterial Catheter Compared to FloWave™ 1000

Congestive Heart FailureIschemic Cardiomyopathy4 more

The purpose of this study is to compare cardiac output results obtained using the thermodilution push technique with the Pulmonary Arterial Catheter (PAC) to the predicted cardiac output results obtained from the non-invasive FloWave™ 1000 device.

Completed8 enrollment criteria
1...131415

Need Help? Contact our team!


We'll reach out to this number within 24 hrs