CMR Based Prediction of Ventricular Tachycardia Events in Healed Myocardial Infarction (DEVELOP-VT)...
Myocardial InfarctionMyocardial Infarction Old6 moreFibrotic tissue is known to be the substrate for the appearance of scar-related reentrant ventricular arrhythmias (VA) in chronic ischemic cardiomyopathy (ICM). Late gadolinium enhancement cardiac magnetic resonance (LGE-CMR) has proven to be a useful technique in the non-invasive characterization of the scarred tissue and the underlying arrhythmogenic substrate. Previous studies identified the presence of significant scarring (> 5% of the left ventricular -LV- mass) is an independent predictor of adverse outcome (all-cause mortality or appropriate ICD discharge for ventricular tachycardia or fibrillation) in patients being considered for implantable cardioverter-defibrillator (ICD) placement. Parallelly, the presence of heterogeneous tissue channels, which correlate with voltage channels after endocardial voltage mapping of the scar, can be more frequently observed in patients suffering from sustained monomorphic ventricular tachycardias (SMVT) than in matched controls for age, sex, infarct location, and left ventricular ejection fraction (LVEF). However, the lack of solid evidence and randomized trials make LVEF still the main decision parameter when assessing suitability for ICD implantation in primary prevention of sudden cardiac death (SCD). In a recent, case-control study, we identified the border zone channel (BZC) mass as the only independent predictor for VT occurrence, after matching for age, sex, LVEF and total scar mass. This BZC mass can be automatically calculated using a commercially available, post-processing imaging platform named ADAS 3D LV (ADAS3D Medical, Barcelona, Spain), with FDA 510(k) Clearance and European Community Mark approval. Thus, CMR-derived BZC mass might be used as an automatically reproducible criterium to reclassify those patients with chronic ICM at highest risk for developing VA/SCD in a relatively short period of approx. 2 years. In the present cohort study, we sought to evaluate the usefulness of the BZC mass measurement to predict the occurrence of VT events in a prospective, multicenter, unselected series of consecutive chronic ischemic patients without previous arrhythmia evidence, irrespectively of their LVEF.
SMART Identification of Ventricular Tachycardia Isthmus
Ventricular TachycardiaIschemic CardiomyopathyContext : Ventricular tachycardia (VT) are serious heart rhythm disorders which can lead to sudden death. A curative treatment for these abnormalities in the cardiac electrical conduction system is possible through an interventional electrophysiology procedure. A catheter is inserted, generally via a femoral access, and is introduced in the heart ventricles in order to collect various 3D electro-anatomical maps. The pace-mapping technique developed in Nancy (de Chillou et al, Heart Rhythm 2014) allows the reentrant circuit underlying the VT to be identified, as well as a definition of the target zones to be ablated, using radiofrequency energy with the catheter. The pace-mapping technique consists of stimulating the ventricle from various sites within its internal surface, in order to generate different activation pathways of the myocardium. When an activation pathway is similar to the VT pathway, this means that the stimulation site is located near the pathologic zone to be ablated. The surface electrocardiogram (ECG) is used to compare activation pathways. A 3D correlation ma is then generated: the zones with high correlation (>90%) indicated the exit of the reentrant circuit, while rapid transition zones (several %/mm) indicate the entrance of the VT circuit. The pace-mapping technique has several limitations: (i) it requires an ECG recording of the clinical VT of the patient (spontaneous or induced at the beginning of the procedure), however it is not always possible to induce it; (ii) sometimes several VT circuits may be present, rendering the procedure of identification and ablation non-exhaustive. The aim of this study is to analyze retrospectively electroanatomical data collected during the intervention, in order to develop a new method for identifying target zones to be ablated, and to compare the results with the conventionally used method. Hypothesis : The investigators hypothesize that alternative methods to analyze electroanatomical data (surface ECG and spatial coordinates of the pacing sites) could provide information equivalent to conventional methods (e.g. VT correlation map, VT activation maps etc…) without the need for a reference recording of the clinical VT of the patient.
Improving Patient Reported Outcome Measures in Catheter Ablation
Ventricular TachycardiaICD1 moreThis study will assess whether more frequent measurement of patient reported outcome measures (PROMs) - specifically health related quality of life (HRQL) - can improve the evaluation of the clinical effectiveness and cost-effectiveness of catheter ablation of ventricular tachycardia (VT) in patients with an Implantable Cardioverter Defibrillator (ICD). It is designed to have feasibility outcomes which contribute to answering the above.
INTERVENE: Indian Trial of Endocardial Ventricular Substrate Ablation to Prevent Recurrent VT Events...
Ventricular TachycardiaThis study to is being conducted in India to determine the role of catheter-based ablation for ventricular tachycardia (VT) in post- heart attack patients who meet established guidelines for implantable cardiodefibrillator (ICD) implantation, but cannot afford it. These patients would be started on chronic Amiodarone therapy, which has been shown to be effective but can often lead to multiple side effects. Patients will therefore be randomized in an even proportion to either a) the control group, receiving chronic Amiodarone therapy, or the study group, undergoing catheter ablation of VT in addition to chronic Amiodarone therapy. This trial will serve as a representative model for the developing world.
Substrate Targeted Ablation Using the FlexAbility™ Ablation Catheter System for the Reduction of...
Monomorphic Ventricular TachycardiaTo demonstrate that scar-based ventricular tachycardia (VT) ablation using the FlexAbility™ ablation catheter system results in a superior clinical outcome compared to routine drug therapy in subjects with documented Monomorphic Ventricular Tachycardia [MMVT] (both ischemic and non-ischemic) while maintaining an acceptable safety profile.
Iv Amiodarone Versus Iv Procainamide to Treat Haemodynamically Well Tolerated Ventricular Tachycardia...
Ventricular TachycardiaWide QRS TachycardiaThe purpose of this study is to determine whether intravenous amiodarone has less cardiac significant adverse events compared to intravenous procainamide in the acute treatment of haemodynamically well tolerated wide QRS tachycardia, the majority of them of probably ventricular origen.
Safety Study of Intranasal Etripamil for the Termination of Spontaneous Episodes of Paroxysmal Supraventricular...
Paroxysmal Supraventricular TachycardiaThe primary objective of this study is to evaluate the safety of etripamil nasal spray (NS) 70 mg when self-administered by patients with an episode of Paroxysmal Supraventricular Tachycardia in an outpatient setting (i.e., without medical supervision).
Therapy Cool Path Ablate VT
Ischemic Ventricular TachycardiaTo demonstrate that ablation with the Therapy Cool Path Duo cardiac ablation system can eliminate ischemic VT and that its use does not result in an unacceptable risk of serious adverse events.
Anti-arrhythmic Therapy vs Catheter Ablation as First Line Treatment for AICD Shock Prevention
Ventricular TachycardiaVentricular ArrhythmiaThe purpose of this study is to determine whether catheter based ablation is better than conventional anti-arrhythmic drug (AAD) therapy for reducing recurrent shocks in patients with an implantable cardioverter defibrillator (ICD). The second purpose of the study is to determine the safety of catheter-based ablation and the effect on quality of life of patients. The study hypothesis is that catheter ablation is superior to AAD therapy in preventing recurrent ventricular arrhythmia in such subjects. This is a pilot trial which will provide data regarding recruitment potential and the feasibility of conducting a larger trial.
Comparison of VT Ablation Outcomes Using Remote MAGNETIC Navigation Versus Manual Approach in a...
TachycardiaVentricularThe study purpose is to demonstrate that ventricular tachycardia (VT) ablation using the Niobe™ ES system results in superior outcomes compared to a manual approach in subjects with ischemic scar VT in a low ejection fraction population.