Spectral Domain Optical Coherence Tomography Analysis for Glaucoma
GLAUCOMA 1OPEN ANGLE1 moreThe aim of this study is to examine whether there is a difference in macular ganglion cell complex thickness and retinal nerve fiber layer thickness in early-stage Primary open angle glaucoma and normal tension glaucoma with spectral domain OCT.

Effectiveness and Safety of Adipose-Derived Regenerative Cells for Treatment of Glaucomatous Neurodegeneration...
Retinal DegenerationPrimary Open-Angle GlaucomaAutologous adipose-derived regenerative cells (ADRC) extracted using Celution 800/CRS System (Cytori Therapeutics Inc) from a portion of the fat harvested from the patient's front abdominal wall. ADRC will be administered one-time into subtenon space of patient's eyeball. This is a single arm study with no control. All patients receive cell therapy.

An Evaluation of Use of Topical Ocular Hypotensive Medication by Compliance
GlaucomaOcular HypertensionThis is an open-label study in patients who are currently using either a topical prostaglandin as sole ocular hypotensive medical therapy q.d., or a topical prostaglandin plus an adjunctive topical ocular hypotensive marketed product either q.d., or b.i.d. in the same eye(s). Compliance will be measured over the two months of participation.

Prevalence of Glaucoma in Belgium: a Multicenter National Trial
GlaucomaTo screen for the presence of glaucoma in a Belgian population over 40 years old using an AI algorithm developed for the detection of glaucoma based on fundus pictures.

MIGS VS SLT Comparison in Glaucoma Patients
GlaucomaTo compare the intraocular pressure (IOP) and number of glaucoma medications lowering of microinvasive glaucoma surgery (MIGS) with the implantation of the trabecular device Hydrus (Ivantis) as a solo procedure and 360° selective laser trabeculoplasty (SLT) to treat primary open angle glaucoma (POAG).

Goldmann Applanation Tonometry, Dynamic Contour Tonometry, and Corvis ST Tonometer
GlaucomaThe study is investigating Intra ocular pressure (IOP) by Goldmann Applanation Tonometry, Dynamic Contour Tonometry, and the Corvis ST tonometer.

Intraocular Pressure and Hemodialysis Midwestern Brazil
Renal InsufficiencyChronic1 moreObjective: To evaluate the variation in intraocular pressure in patients with chronic kidney disease, according to the time interval between hemodialysis sessions and to the influence of weight and blood pressure on intraocular pressure. Methods: This was a cross-sectional study in which 78 eyes of 39 patients on hemodialysis, at the Santa Casa de Misericordia de Goiânia hospital, were analyzed in June 2014. Patients were divided into groups according to the days on which they underwent hemodialysis. The mean, standard deviation, and median of the intraocular pressure, blood pressure, and weight were calculated. P-values <0.05 were considered statistically significant.

Reproducibility of RNFL and ONH Measurements in OAG With Heidelberg Spectralis SD-OCT Glaucoma Module...
Primary Open Angle GlaucomaThe purpose of this study is to assess and compare the repeatability of SD-OCT (Spectralis™ OCT, Version 6.0, Heidelberg Engineering, Germany) RNFL thickness measurements with a new software (glaucoma premium module) with the well established peripapillary RNFL thickness measurements in patients with primary open angle glaucoma.

Spectralis OCT Repeatability and Reproducibility Study
GlaucomaThis single-center, prospective, interventional clinical study is conducted to evaluate the repeatability and reproducibility of structural parameters of the optic nerve head, the peripapillary retinal nerve fiber layer, and the macula using the Heidelberg Spectralis OCT (Optical Coherence Tomography) device. Data obtained from healthy volunteers in this study are compared to those from a previous, larger healthy volunteer study that was conducted in the United States and Europe (S-2012-1), and data from glaucoma patients are compared to those from the healthy volunteers.

Partial Least Squares Regression Modelling for Glaucoma Detection
GlaucomaA partial least squares regression model for visual field testing among glaucoma patients will be developed. In addition, microperimetry will be compared to conventional perimetry and reproducibility will be assessed.