Comparison Between Volume Controlled Ventilation and Pressure Controlled Ventilation
Primary Purpose
Obesity, Reduced Lung Compliance., Anesthesia.
Status
Completed
Phase
Not Applicable
Locations
France
Study Type
Interventional
Intervention
Mechanical Ventilation
Sponsored by

About this trial
This is an interventional treatment trial for Obesity focused on measuring Obesity., Respiration. Respiration, artificial., Ventilation. Pressure controlled. Volume controlled.
Eligibility Criteria
Inclusion Criteria: patients are over 18 years old and give their inform consent morbid obesity(BMI>35) laparoscopic bariatric surgery Exclusion Criteria: -
Sites / Locations
- Georges Pompidou European Hospital
Outcomes
Primary Outcome Measures
Plateau pressures generated by mechanical ventilation after 45 minutes of pneumoperitoneum.
Secondary Outcome Measures
Comparison of PaO2 and PaCO2 after 45 minutes of pneumoperitoneum and after 2 hours spent in post-anesthesia care unit ; comparison of total respiratory resistances and peak flow generated between the 2 modes.
Full Information
NCT ID
NCT00224653
First Posted
September 16, 2005
Last Updated
April 12, 2006
Sponsor
Assistance Publique - Hôpitaux de Paris
1. Study Identification
Unique Protocol Identification Number
NCT00224653
Brief Title
Comparison Between Volume Controlled Ventilation and Pressure Controlled Ventilation
Study Type
Interventional
2. Study Status
Record Verification Date
September 2005
Overall Recruitment Status
Completed
Study Start Date
January 2005 (undefined)
Primary Completion Date
undefined (undefined)
Study Completion Date
June 2005 (undefined)
3. Sponsor/Collaborators
Name of the Sponsor
Assistance Publique - Hôpitaux de Paris
4. Oversight
5. Study Description
Brief Summary
To assess the potential benefits on mechanical ventilation plateau pressure of pressure controlled mode versus volume controlled mode for laparoscopic bariatric surgery in obese patients (BMI > 35). High plateau pressures encountered in obese patients due to their reduced pulmonary compliance could be lowered using pressure controlled mechanical ventilation.
Detailed Description
All patients are over 18 years old and give their inform consent after approval of the study protocol by an ethic committee. Anesthesia is standardized and all patients are intubated. Precise protocols are used to perform pressure and volume controlled ventilation in order to regulate End-Tidal CO2 between 33 and 35 mmHg. Primary goal is comparison of plateau pressures observed in the 2 ventilation modes after 45 minutes of pneumoperitoneum. Secondary goals are : comparison of PaO2 and PaCO2 after 45 minutes of pneumoperitoneum and after 2 hours spent in post-anesthesia care unit ; comparison of total respiratory resistances and peak flow generated between the 2 modes.
6. Conditions and Keywords
Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Obesity, Reduced Lung Compliance., Anesthesia., Laparoscopy.
Keywords
Obesity., Respiration. Respiration, artificial., Ventilation. Pressure controlled. Volume controlled.
7. Study Design
Primary Purpose
Treatment
Study Phase
Not Applicable
Interventional Study Model
Parallel Assignment
Masking
Single
Allocation
Randomized
Enrollment
36 (false)
8. Arms, Groups, and Interventions
Intervention Type
Procedure
Intervention Name(s)
Mechanical Ventilation
Primary Outcome Measure Information:
Title
Plateau pressures generated by mechanical ventilation after 45 minutes of pneumoperitoneum.
Secondary Outcome Measure Information:
Title
Comparison of PaO2 and PaCO2 after 45 minutes of pneumoperitoneum and after 2 hours spent in post-anesthesia care unit ; comparison of total respiratory resistances and peak flow generated between the 2 modes.
10. Eligibility
Sex
All
Minimum Age & Unit of Time
18 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria:
patients are over 18 years old and give their inform consent
morbid obesity(BMI>35)
laparoscopic bariatric surgery
Exclusion Criteria:
-
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Philippe CADI, MD
Organizational Affiliation
Assistance Publique - Hôpitaux de Paris
Official's Role
Principal Investigator
Facility Information:
Facility Name
Georges Pompidou European Hospital
City
Paris
State/Province
Ile de France
ZIP/Postal Code
75908 cedex 15
Country
France
12. IPD Sharing Statement
Citations:
PubMed Identifier
12707159
Citation
Frappier J, Guenoun T, Journois D, Philippe H, Aka E, Cadi P, Silleran-Chassany J, Safran D. Airway management using the intubating laryngeal mask airway for the morbidly obese patient. Anesth Analg. 2003 May;96(5):1510-1515. doi: 10.1213/01.ANE.0000057003.91393.3C.
Results Reference
background
Learn more about this trial
Comparison Between Volume Controlled Ventilation and Pressure Controlled Ventilation