Percentage of Participants Who Reported 1 or More Adverse Event (AE) - Healthy Participants
An AE was defined as any untoward medical occurrence in a participant which does not necessarily have a causal relationship with the treatment. An AE was any unfavorable and unintended sign (including an abnormal laboratory finding), symptom, or disease temporally associated with use of a medicinal product, regardless of whether or not it was considered related to the medicinal product. The percentage of participants that reported at least 1 AE was summarized. AEs are reported by the dose taken at the time of the event.
Percentage of Participants Who Were Discontinued From the Study Due to an AE - Healthy Participants
An AE was defined as any untoward medical occurrence in a participant which does not necessarily have a causal relationship with the treatment. An AE was any unfavorable and unintended sign (including an abnormal laboratory finding), symptom, or disease temporally associated with use of a medicinal product, regardless of whether or not it was considered related to the medicinal product. The percentage of participants who were discontinued from the study due to an AE were summarized. AEs are reported by the dose taken at the time of the event.
Percentage of Participants Who Report 1 or More Adverse Event (AE) - Hypertensive Participants
An AE was defined as any untoward medical occurrence in a participant which does not necessarily have a causal relationship with the treatment. An AE was any unfavorable and unintended sign (including an abnormal laboratory finding), symptom, or disease temporally associated with use of a medicinal product, regardless of whether or not it was considered related to the medicinal product. The percentage of participants that reported at least 1 AE was summarized. The percentage of participants that reported at least 1 AE was summarized. AEs are reported by the dose taken at the time of the event.
Percentage of Participants Who Were Discontinued From the Study Due to an AE - Hypertensive Participants
An AE was defined as any untoward medical occurrence in a participant which does not necessarily have a causal relationship with the treatment. An AE was any unfavorable and unintended sign (including an abnormal laboratory finding), symptom, or disease temporally associated with use of a medicinal product, regardless of whether or not it was considered related to the medicinal product. The percentage of participants who were discontinued from the study due to an AE were summarized. AEs are reported by the dose taken at the time of the event.
Area Under the Concentration Time-curve From Hour 0 to Infinity (AUC0-inf) of MK-3614 - Healthy Participants
Blood samples taken at Predose, and 0.5, 1, 2, 4, 6, 8, 12, 16, 24, 36, and 48 hours postdose of each dosing period to determine the AUC0-inf of MK-3614 in healthy participants.
Maximum Concentration (Cmax) of MK-3614- Healthy Participants
Blood samples taken at Predose, and 0.5, 1, 2, 4, 6, 8, 12, 16, 24, 36, and 48 hours postdose of each dosing period to determine the Cmax of MK-3614 in healthy participants.
Time to Cmax (Tmax) of MK-3614- Healthy Participants
Blood samples taken at Predose, and 0.5, 1, 2, 4, 6, 8, 12, 16, 24, 36, and 48 hours postdose of each dosing period to determine the Tmax of MK-3614 in healthy participants.
Apparent Terminal Half-life (t1/2) of MK-3614- Healthy Participants
Blood samples taken at Predose, and 0.5, 1, 2, 4, 6, 8, 12, 16, 24, 36, and 48 hours postdose of each dosing period to determine the t1/2 of MK-3614 in healthy participants.
Area Under the Concentration Time-curve From Hour 0 to Infinity (AUC0-inf) of MK-3614 - Hypertensive Participants
Blood samples taken at Predose, and 0.5, 1, 2, 4, 6, 8, 12, 16, 24, 36, and 48 hours postdose of each dosing period to determine the AUC0-inf of MK-3614 in hypertensive participants
Maximum Concentration (Cmax) of MK-3614- Hypertensive Participants
Blood samples taken at Predose, and 0.5, 1, 2, 4, 6, 8, 12, 16, 24, 36, and 48 hours postdose of each dosing period to determine the Cmax of MK-3614 in hypertensive participants
Time to Cmax (Tmax) of MK-3614- Hypertensive Participants
Blood samples taken at Predose, and 0.5, 1, 2, 4, 6, 8, 12, 16, 24, 36, and 48 hours postdose of each dosing period to determine the Tmax of MK-3614 in hypertensive participants
Apparent Terminal Half-life (t1/2) of MK-3614 of MK-3614- Hypertensive Participants
Blood samples taken at Predose, and 0.5, 1, 2, 4, 6, 8, 12, 16, 24, 36, and 48 hours postdose of each dosing period to determine the t1/2 of MK-3614 in hypertensive participants
Change From Baseline in Heart Rate - Healthy Participants
Heart rate measurements were obtained using a validated, semi-automated oscillometric device. The difference between the predose (baseline) measurement and the measurement 24 obtained 24 hours postdose was summarized. Data for each specific dose were combined regardless of panel.
Change From Baseline in Brachial Arterial Systolic Blood Pressure - Healthy Participants
Brachial arterial systolic blood pressure measurements were obtained using a validated, semi-automated oscillometric device. The difference between the predose (baseline) measurement and the measurement 24 obtained 24 hours postdose was summarized. Data for each specific dose were combined regardless of panel.
Change From Baseline in Brachial Arterial Diastolic Blood Pressure - Healthy Participants
Brachial arterial diastolic blood pressure measurements were obtained using a validated, semi-automated oscillometric device. The difference between the predose (baseline) measurement and the measurement 24 obtained 24 hours postdose was summarized. Data for each specific dose were combined regardless of panel.
Change From Baseline in Heart Rate - Hypertensive Participants
HR measurements were obtained using a validated, semi-automated oscillometric device. The difference between the predose (baseline) measurement and the measurement 24 obtained 24 hours postdose was summarized. Data for each specific dose were combined regardless of sequence.
Change From Baseline in Brachial Arterial Systolic Blood Pressure - Hypertensive Participants
Brachial arterial systolic blood pressure measurements were obtained using a validated, semi-automated oscillometric device. The difference between the predose (baseline) measurement and the measurement 24 obtained 24 hours postdose was summarized. Data for each specific dose were combined regardless of sequence.
Change From Baseline in Brachial Arterial Diastolic Blood Pressure - Hypertensive Participants
Brachial arterial diastolic blood pressure measurements were obtained using a validated, semi-automated oscillometric device. The difference between the predose (baseline) measurement and the measurement 24 obtained 24 hours postdose was summarized. Data for each specific dose were combined regardless of sequnce.
Area Under the Concentration Time-curve From Hour 0 to Infinity (AUC0-inf) of 0.25 mg MK-3614 - Healthy Participants- Fasted Versus Fed
Blood samples taken at Predose, and 0.5, 1, 2, 4, 6, 8, 12, 16, 24, 36, and 48 hours postdose of each dosing period to determine the AUC0-inf of 0.25 mg MK-3614 in healthy participant when administered after an 8 hour fast and after a high-fat breakfest.
Maximum Concentration (Cmax) of 0.25 mg MK-3614 - Healthy Participants- Fasted Versus Fed
Blood samples taken at Predose, and 0.5, 1, 2, 4, 6, 8, 12, 16, 24, 36, and 48 hours postdose of each dosing period to determine the Cmax of 0.25 mg MK-3614 when administered after an 8 hour fast and after a high-fat breakfest.
Percentage Change From Baseline in Augmentation Index (AIx) at 24 Hours Postdose - Healthy Participants
Augmentation index was measured at predose (baseline), and 1, 4, 8, 12, and 24 hours postdose by aplanation tonometry of radial artery. The change from baseline at 24 hours postdose was summarized. Data for each specific dose were combined regardless of panel.
Percentage Change From Baseline in Augmentation Index (AIx) at 24 Hours Postdose - Hypertensive Participants
Augmentation index was measured at predose (baseline), and 1, 4, 8, 12, and 24 hours postdose by aplanation tonometry of radial artery. The change from baseline at 24 hours postdose was summarized.
Percentage Change From Baseline in Bleeding Time at 24 Hours Postdose - Healthy Participants
Blood was to be drawn at predose (baseline) and 3 and 24 hours postdose and bleeding time was to be assessed using a Newborn Surgicutt device. Change in bleeding time from baseline at 24 hours postdose were to be summarized. Due to change in number of blood draws and total blood volume restrictions, bleeding time assessment was not performed as planned.
Percentage Change From Baseline in Bleeding Time at 24 Hours Postdose- Hypertension Participants
Blood was to be drawn at predose (baseline) and 3 and 24 hours postdose and bleeding time was to be assessed using a Newborn Surgicutt device. Change in bleeding time from baseline at 24 hours postdose were to be summarized. Due to change in number of blood draws and total blood volume restrictions, bleeding time assessment was not performed as planned.
Percentage Change in Cyclic Guanosine Monophosphate (GMP) From Baseline at 24 Hours Postdose - Healthy Participants
Blood was drawn at predose (baseline) and 1, 4, 8, and 24 hours postdose. The change in cyclic GMP at 24 hours postdose was summarized. Due to change in number of blood draws and total blood volume restrictions, data for GMP were only collected for first 2 periods of each panel. Therefore only limited data were available and summarized. Data for each specific dose were combined regardless of panel.
Percentage Change in Cyclic Guanosine Monophosphate (GMP) From Baseline at 24 Hours Postdose - Hypertension Participants
Blood was drawn at predose (baseline) and 1, 4, 8, and 24 hours postdose. The change in cyclic GMP at 24 hours postdose was summarized. Due to change in number of blood draws and total blood volume restrictions, data for GMP were only collected for first 2 periods of each panel. Therefore only limited data were available and summarized.
Percentage Change From Baseline in Platelet Aggregation at 24 Hours Postdose - Healthy Participants
Platelet aggregation induced by adenosine diphosphate (ADP) was measured at predose (baseline) and 3 and 24 hours postdose. Percent inhibition from baseline at 24 hours postdose was calculated. Due to change in number of blood draws and total blood volume restrictions, data for platelet aggregation were only collected for first 2 periods of each panel. Therefore only limited data were available and summarized. Data for each specific dose were combined regardless of panel.
Percentage Change From Baseline in Platelet Aggregation at 24 Hours Postdose - Hypertensive Participants
Platelet aggregation induced by adenosine diphosphate (ADP) was measured at predose (baseline) and 3 and 24 hours postdose. Percent inhibition from baseline at 24 hours postdose was calculated. Due to change in number of blood draws and total blood volume restrictions, data for platelet aggregation were only collected for first 2 periods of each panel. Therefore only limited data were available and summarized.