Prospective Study of an Investigational Toric Soft Contact Lens
Primary Purpose
Myopia, Astigmatism, Refractive Error
Status
Completed
Phase
Not Applicable
Locations
Study Type
Interventional
Intervention
Nelfilcon A toric contact lenses (with comfort additives)
Nelfilcon A toric contact lenses
Sponsored by
About this trial
This is an interventional treatment trial for Myopia focused on measuring toric, contact lenses, daily disposable contact lenses, astigmatism, soft contact lenses, contact lens comfort
Eligibility Criteria
Inclusion Criteria:
- Sign Informed Consent document. If under legal age of consent, legally authorized representative must sign Informed Consent document and participant must sign Assent document.
- Normal eyes not using any ocular medications that would contraindicate lens wear.
- Willing and able to wear toric contact lenses in both eyes within the available range of powers for this trial.
- Spectacle cylinder prescription between 0.50 and 2.00 diopters.
- Best spectacle corrected visual acuity 20/25 (Snellen) or better in each eye at distance.
- Other protocol-defined inclusion criteria may apply.
Exclusion Criteria:
- Anterior segment infection, inflammation, or abnormality.
- Any active anterior segment or systemic disease that would contraindicate contact lens wear.
- Use of systemic medications that would contraindicate lens wear.
- Any ocular or systemic medical condition that may, in the opinion of the investigator, preclude safe administration of the study lenses or affect the results of this study.
- History of herpetic keratitis.
- History of refractive surgery or irregular cornea.
- History of pathologically dry eye.
- Corneal vascularization greater than 1 mm of penetration.
- Eye injury within twelve weeks immediately prior to enrollment in this trial.
- Participation in a contact lens or contact lens care product clinical trial within the previous 30 days, or concurrent participation in any clinical trial.
- Other protocol-defined exclusion criteria may apply.
Sites / Locations
Arms of the Study
Arm 1
Arm 2
Arm Type
Experimental
Active Comparator
Arm Label
DAILIES® AquaComfort Plus® Toric
Focus® DAILIES® Toric
Arm Description
Nelfilcon A toric contact lenses (with comfort additives) worn in both eyes on a daily wear, daily disposable basis for three months
Nelfilcon A toric contact lenses worn in both eyes on a daily wear, daily disposable basis for three months
Outcomes
Primary Outcome Measures
Contact Lens-Corrected Distance Monocular Snellen Visual Acuity (VA) (20/30 or Better)
Visual acuity, as assessed for each eye individually. Participant read a distance Snellen chart while wearing study lenses. The percentage of eyes with VA recorded as 20/30 or better is reported. Both eyes contributed to the percentage.
Secondary Outcome Measures
Subjective Rating of Insertion Comfort
Insertion comfort (30 seconds to 1 minute), as rated by the participant on a 10-point scale, with 1 being poor and 10 being excellent. The participant rated both eyes together by providing one single rating.
Subjective Rating of End of Day Comfort
End of day comfort, as rated by the participant on a 10-point scale, with 1 being poor and 10 being excellent. The participant rated both eyes together by providing one single rating.
Subjective Rating of Overall Comfort
Overall comfort, as rated by the participant on a 10-point scale, with 1 being poor and 10 being excellent. The participant rated both eyes together by providing one single rating.
Subjective Rating of End of Day Dryness
End of day dryness, as rated by the participant on a 10-point scale, with 1 being dry and 10 being not dry. The participant rated both eyes together by providing one single rating.
Subjective Rating of Overall Vision
Overall vision, as rated by the participant on a 10-point scale, with 1 being poor and 10 being excellent. The participant rated both eyes together by providing one single rating.
Subjective Rating of Overall Handling
Overall handling, as rated by the participant on a 10-point scale, with 1 being difficult and 10 being easy. The participant rated both eyes together by providing one single rating.
Lens Centration (Centered, Slight Decentration)
Lens centration, as assessed by the investigator for each eye individually. Lens centration was graded on a 5-point scale: 0=centered, 1=slight decentration, 2=mild decentration, 3=moderate decentration, 4=severe decentration. The combined percentage of lenses assessed as "centered" or "slight decentration" is reported. Lenses from both eyes contributed to the percentage.
Lens Fit (Optimal, Acceptably Loose, Acceptably Tight)
Lens fit, as assessed by the investigator for each eye individually. Lens fit was graded on a 5-point scale: 2=unacceptably loose, 1=acceptably loose, 0=optimal, -1=acceptably tight, and -2=unacceptably tight. The combined percentage of lenses assessed as "optimal," "acceptably loose," or "acceptably tight" is reported. Lenses from both eyes contributed to the percentage.
Front Surface Wettability (None, Very Slight)
Front surface wettability (i.e., assessment of the disruption of the front surface wettability of the contact lens), as assessed by the investigator for each eye individually. Front surface wettability was graded on a 5-point scale: 0=none, 1=very slight, 2=slight, 3=moderate, 4=severe. The combined percentage of lenses assessed as "none" or "very slight" is reported. Lenses from both eyes contributed to the percentage.
Front Surface Deposits (None, Very Slight)
Front surface deposits on the contact lens, as assessed by the investigator for each eye individually. Front surface deposits were graded on a 5-point scale: 0=none, 1=very slight, 2=slight, 3=moderate, 4=severe. The combined percentage of lenses assessed as "none" or "very slight" is reported. Lenses from both eyes contributed to the percentage.
Back Surface Debris/Deposits (None, Very Slight)
Back surface debris/deposits on the contact lens, as assessed by the investigator for each eye individually. Back surface debris/deposits were graded on a 5-point scale: 0=none, 1=very slight, 2=slight, 3=moderate, 4=severe. The combined percentage of lenses assessed as "none" or "very slight" is reported. Lenses from both eyes contributed to the percentage.
Full Information
1. Study Identification
Unique Protocol Identification Number
NCT01461811
Brief Title
Prospective Study of an Investigational Toric Soft Contact Lens
Official Title
ARES Registration Trial
Study Type
Interventional
2. Study Status
Record Verification Date
August 2013
Overall Recruitment Status
Completed
Study Start Date
December 2011 (undefined)
Primary Completion Date
April 2012 (Actual)
Study Completion Date
April 2012 (Actual)
3. Sponsor/Collaborators
Responsible Party, by Official Title
Sponsor
Name of the Sponsor
CIBA VISION
4. Oversight
Data Monitoring Committee
No
5. Study Description
Brief Summary
The purpose of this study was to demonstrate substantial equivalence of an investigational toric soft contact lens to the commercially available Focus® DAILIES® Toric soft contact lens when worn in a daily wear, daily disposable mode for three months.
Detailed Description
Eligible participants were randomized 2:1 to wear either DAILIES® AquaComfort Plus® Toric or Focus® DAILIES® Toric.
6. Conditions and Keywords
Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Myopia, Astigmatism, Refractive Error
Keywords
toric, contact lenses, daily disposable contact lenses, astigmatism, soft contact lenses, contact lens comfort
7. Study Design
Primary Purpose
Treatment
Study Phase
Not Applicable
Interventional Study Model
Parallel Assignment
Masking
Participant
Allocation
Randomized
Enrollment
154 (Actual)
8. Arms, Groups, and Interventions
Arm Title
DAILIES® AquaComfort Plus® Toric
Arm Type
Experimental
Arm Description
Nelfilcon A toric contact lenses (with comfort additives) worn in both eyes on a daily wear, daily disposable basis for three months
Arm Title
Focus® DAILIES® Toric
Arm Type
Active Comparator
Arm Description
Nelfilcon A toric contact lenses worn in both eyes on a daily wear, daily disposable basis for three months
Intervention Type
Device
Intervention Name(s)
Nelfilcon A toric contact lenses (with comfort additives)
Intervention Type
Device
Intervention Name(s)
Nelfilcon A toric contact lenses
Other Intervention Name(s)
Focus® DAILIES® Toric
Primary Outcome Measure Information:
Title
Contact Lens-Corrected Distance Monocular Snellen Visual Acuity (VA) (20/30 or Better)
Description
Visual acuity, as assessed for each eye individually. Participant read a distance Snellen chart while wearing study lenses. The percentage of eyes with VA recorded as 20/30 or better is reported. Both eyes contributed to the percentage.
Time Frame
Up to Month 3
Secondary Outcome Measure Information:
Title
Subjective Rating of Insertion Comfort
Description
Insertion comfort (30 seconds to 1 minute), as rated by the participant on a 10-point scale, with 1 being poor and 10 being excellent. The participant rated both eyes together by providing one single rating.
Time Frame
Up to Month 3
Title
Subjective Rating of End of Day Comfort
Description
End of day comfort, as rated by the participant on a 10-point scale, with 1 being poor and 10 being excellent. The participant rated both eyes together by providing one single rating.
Time Frame
Up to Month 3
Title
Subjective Rating of Overall Comfort
Description
Overall comfort, as rated by the participant on a 10-point scale, with 1 being poor and 10 being excellent. The participant rated both eyes together by providing one single rating.
Time Frame
Up to Month 3
Title
Subjective Rating of End of Day Dryness
Description
End of day dryness, as rated by the participant on a 10-point scale, with 1 being dry and 10 being not dry. The participant rated both eyes together by providing one single rating.
Time Frame
Up to Month 3
Title
Subjective Rating of Overall Vision
Description
Overall vision, as rated by the participant on a 10-point scale, with 1 being poor and 10 being excellent. The participant rated both eyes together by providing one single rating.
Time Frame
Up to Month 3
Title
Subjective Rating of Overall Handling
Description
Overall handling, as rated by the participant on a 10-point scale, with 1 being difficult and 10 being easy. The participant rated both eyes together by providing one single rating.
Time Frame
Up to Month 3
Title
Lens Centration (Centered, Slight Decentration)
Description
Lens centration, as assessed by the investigator for each eye individually. Lens centration was graded on a 5-point scale: 0=centered, 1=slight decentration, 2=mild decentration, 3=moderate decentration, 4=severe decentration. The combined percentage of lenses assessed as "centered" or "slight decentration" is reported. Lenses from both eyes contributed to the percentage.
Time Frame
Up to Month 3
Title
Lens Fit (Optimal, Acceptably Loose, Acceptably Tight)
Description
Lens fit, as assessed by the investigator for each eye individually. Lens fit was graded on a 5-point scale: 2=unacceptably loose, 1=acceptably loose, 0=optimal, -1=acceptably tight, and -2=unacceptably tight. The combined percentage of lenses assessed as "optimal," "acceptably loose," or "acceptably tight" is reported. Lenses from both eyes contributed to the percentage.
Time Frame
Up to Month 3
Title
Front Surface Wettability (None, Very Slight)
Description
Front surface wettability (i.e., assessment of the disruption of the front surface wettability of the contact lens), as assessed by the investigator for each eye individually. Front surface wettability was graded on a 5-point scale: 0=none, 1=very slight, 2=slight, 3=moderate, 4=severe. The combined percentage of lenses assessed as "none" or "very slight" is reported. Lenses from both eyes contributed to the percentage.
Time Frame
Up to Month 3
Title
Front Surface Deposits (None, Very Slight)
Description
Front surface deposits on the contact lens, as assessed by the investigator for each eye individually. Front surface deposits were graded on a 5-point scale: 0=none, 1=very slight, 2=slight, 3=moderate, 4=severe. The combined percentage of lenses assessed as "none" or "very slight" is reported. Lenses from both eyes contributed to the percentage.
Time Frame
Up to Month 3
Title
Back Surface Debris/Deposits (None, Very Slight)
Description
Back surface debris/deposits on the contact lens, as assessed by the investigator for each eye individually. Back surface debris/deposits were graded on a 5-point scale: 0=none, 1=very slight, 2=slight, 3=moderate, 4=severe. The combined percentage of lenses assessed as "none" or "very slight" is reported. Lenses from both eyes contributed to the percentage.
Time Frame
Up to Month 3
10. Eligibility
Sex
All
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria:
Sign Informed Consent document. If under legal age of consent, legally authorized representative must sign Informed Consent document and participant must sign Assent document.
Normal eyes not using any ocular medications that would contraindicate lens wear.
Willing and able to wear toric contact lenses in both eyes within the available range of powers for this trial.
Spectacle cylinder prescription between 0.50 and 2.00 diopters.
Best spectacle corrected visual acuity 20/25 (Snellen) or better in each eye at distance.
Other protocol-defined inclusion criteria may apply.
Exclusion Criteria:
Anterior segment infection, inflammation, or abnormality.
Any active anterior segment or systemic disease that would contraindicate contact lens wear.
Use of systemic medications that would contraindicate lens wear.
Any ocular or systemic medical condition that may, in the opinion of the investigator, preclude safe administration of the study lenses or affect the results of this study.
History of herpetic keratitis.
History of refractive surgery or irregular cornea.
History of pathologically dry eye.
Corneal vascularization greater than 1 mm of penetration.
Eye injury within twelve weeks immediately prior to enrollment in this trial.
Participation in a contact lens or contact lens care product clinical trial within the previous 30 days, or concurrent participation in any clinical trial.
Other protocol-defined exclusion criteria may apply.
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Mary Fahmy, OD
Organizational Affiliation
Alcon Research
Official's Role
Study Director
12. IPD Sharing Statement